Joint-Transformation-Based Detection of False Data Injection Attacks in Smart Grid
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
For reliable operation and control of smart grid, estimating the correct states is of utmost importance to the system operator. With recent incorporation of information technology and advanced metering infrastructure, the futuristic grid is more prone to cyber-threats. The false data injection (FDI) attack is one of the most thoroughly researched cyber-attacks. Intelligently crafted, it can cause false estimation of states, which further seriously affects the entire power system operation. In this paper, we propose joint-transformation-based scheme to detect FDI attacks in real time. The proposed method is built on the dynamics of measurement variations. Kullback–Leibler distance is used to find out the difference between probability distributions obtained from measurement variations. The proposed method is tested using IEEE 14 bus system considering attack on different state variables. The results shows that the proposed scheme detects FDI attacks with high detection probability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2005) · doi:10.1002/047174882x · Cited by 13,791
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974 · cited 4×
“Bad data is detected by performing the Chi-Square test [25] as follows,”
BackgroundMethodInfluentialFalse data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2011) · ACM Transactions on Information and System Security · doi:10.1145/1952982.1952995 · Cited by 2,428
Qidwai, U., & Chen, C. H. (2009) · Chapman & Hall/CRC eBooks · doi:10.1201/9781420079517 · Cited by 1,701
Power System Static-State Estimation, Part I: Exact Model
Schweppe, F., & Wildes, J. (1970) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1970.292678 · Cited by 1,383
Cyber–Physical System Security for the Electric Power Grid
Sridhar, S., Hahn, A., & Govindarasu, M. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165269 · Cited by 1,208
A new metric for probability distributions
Endres, D. M., & Schindelin, J. E. (2003) · IEEE Transactions on Information Theory · doi:10.1109/tit.2003.813506 · Cited by 1,163 · cited 1×
“Jensen–Shannon distance [22] can also compare the two probability distributions, as applied in this paper, we chose Kullback– Leibler distance (KLD) [23] to calculate the difference between historical true measurement variations and false measurement variations due to comparatively higher detection efficiency.”
MethodSecure Control: Towards Survivable Cyber-Physical Systems
Cardenas, A. A., Amin, S., & Sastry, S. (2008) · 2008 The 28th International Conference on Distributed Computing Systems Workshops · doi:10.1109/icdcs.workshops.2008.40 · Cited by 911 · cited 1×
“data injection (FDI) attack on power system have been reported in [4]–[6].”
BackgroundVulnerability Assessment of Cybersecurity for SCADA Systems
Ten, C.-W., Liu, C.-C., & Manimaran, G. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2002298 · Cited by 583 · cited 1×
“However, the cyber-physical security of the grid is now prone to cyber-attacks [1]–[3].”
BackgroundDetecting False Data Injection Attacks on DC State Estimation
Bobba, R. B., Rogers, K. M., Wang, Q., Khurana, H., Nahrstedt, K., & Overbye, T. J. (2010) · Cited by 448
Cited by
A Survey on the Detection Algorithms for False Data Injection Attacks in Smart Grids
Musleh, A. S., Chen, G., & Dong, Z. Y. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2949998 · Cited by 714
Online False Data Injection Attack Detection With Wavelet Transform and Deep Neural Networks
Yu, J. J. Q., Hou, Y., & Li, V. O. K. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2825243 · Cited by 378
Alotaibi, I., Abido, M. A., Khalid, M., & Savkin, A. V. (2020) · Energies · doi:10.3390/en13236269 · Cited by 314
Distributed Control and Communication Strategies in Networked Microgrids
Zhou, Q., Shahidehpour, M., Paaso, A., Bahramirad, S., Alabdulwahab, A., & Abusorrah, A. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2020.3023963 · Cited by 307
Secure Control of Multiagent Systems Against Malicious Attacks: A Brief Survey
He, W., Xu, W., Ge, X., Han, Q.-L., Du, W., & Qian, F. (2022) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2021.3126644 · Cited by 290
Ahmed, S., Lee, Y., Hyun, S.-H., & Koo, I. (2019) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2019.2902822 · Cited by 287
Deep Learning-Based Interval State Estimation of AC Smart Grids Against Sparse Cyber Attacks
Wang, H., Ruan, J., Wang, G., Zhou, B., Liu, Y., Fu, X., & Peng, J. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2804669 · Cited by 237
“On our experimental platform, the pretraining process only takes 12 min and 16 s, which is far less than the time for completing the length pretraining processes in several previous studies [12], [18], and [49].”
MethodSurvey of machine learning methods for detecting false data injection attacks in power systems
Sayghe, A., Hu, Y., Zografopoulos, I., Liu, X., Dutta, R. G., Jin, Y., & Konstantinou, C. (2020) · IET Smart Grid · doi:10.1049/iet-stg.2020.0015 · Cited by 159
Metadata
- Authors
- Singh, S. K., Khanna, K., Bose, R., Panigrahi, B. K., & Joshi, A.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2018-01
- Volume
- 14
- Issue
- 1
- Pages
- 89-97
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2735539676
- Cited by
- 179
- References
- 26
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.