Feasibility of Wrist-Worn, Real-Time Hand, and Surface Gesture Recognition via sEMG and IMU Sensing
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
While most wearable gesture recognition approaches focus on the forearm or fingers, the wrist may be a more suitable location for practical use. We present the design and validation of a real-time gesture recognition wristband based on surface electromyography and inertial measurement unit sensing fusion, which can recognize 8 air gestures and 4 surface gestures with 2 distinct force levels. Ten healthy subjects performed an initial gesture recognition experiment, followed by a second experiment 1 h later and a third experiment 1 day later. Classification accuracies for the initial experiment were 92.6% and 88.8% for air and surface gestures, respectively, and there were no changes in accuracy results during testing 1 h. and 1 day later (p > 0.05). These results demonstrate the feasibility of wrist-based gesture recognition paving the way for potential future integration in to a smart watch or other wrist-worn wearable for intuitive human computer interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268 · cited 1×
“Despite common knowledge that sEMG signal amplitudes are significantly higher at the muscle belly than in the tendon areas [37], classification results from this study, involving sEMG sensing at the muscle tendons of the wrist, were comparable to other research involving sEMG sensing at the muscle belly of the forearm…”
ResultA new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“In general, delays of 300 ms or less are acceptable for real-time control [22], and we thus choose the segment length of 200 ms based on previous real-time control applications [23].”
MethodA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743 · cited 4×
“Segment length is important in real life applications because segments that are too short can result in large variance within individual features, and segments that are too long can hinder real-time operation [21].”
BackgroundMethodInfluentialSupport Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb
Oskoei, M. A., & Hu, H. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919734 · Cited by 829 · cited 1×
“In general, delays of 300 ms or less are acceptable for real-time control [22], and we thus choose the segment length of 200 ms based on previous real-time control applications [23].”
MethodA Comparison of Surface and Intramuscular Myoelectric Signal Classification
Hargrove, L. J., Englehart, K., & Hudgins, B. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889192 · Cited by 518 · cited 1×
“In previous research, linear discriminant analysis (LDA) did not sacrifice accuracy [25]–[27] with fast speed and simplicity [21], [28] for training.”
BackgroundDigits: freehand 3D interactions anywhere using a wrist-worn gloveless sensor
Kim, D., Hilliges, O., Izadi, S., Butler, A. D., Chen, J., Oikonomidis, I., & Olivier, P. (2012) · Proceedings of the 25th annual ACM symposium on User interface software and technology · doi:10.1145/2380116.2380139 · Cited by 428 · cited 1×
“[15] put cameras on the wrist to directly track a series of 3-D hand poses.”
BackgroundGestureWrist and GesturePad: unobtrusive wearable interaction devices
Rekimoto, J. (2002) · Proceedings Fifth International Symposium on Wearable Computers · doi:10.1109/iswc.2001.962092 · Cited by 410 · cited 3×
“This work Paper [14] Paper [35] Paper [36] Paper [6]”
BackgroundLu, Z., Chen, X., Li, Q., Zhang, X., & Zhou, P. (2014) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2014.2302794 · Cited by 294 · cited 2×
“2779814 interacting with smart phones [2], and even as an aid to help the deaf communicate more effectively with people who don’t un-”
BackgroundMethodSensinger, J. W., Lock, B. A., & Kuiken, T. A. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023282 · Cited by 239 · cited 1×
“However, a primary problem for hand gesture classification is that sEMG signals may differ each time the wristband is taken off and put back on primarily because of electrode shift and variations in electrode conductivity [31].”
BackgroundOrtiz-Catalan, M., Brånemark, R., & Håkansson, B. (2013) · Source Code for Biology and Medicine · doi:10.1186/1751-0473-8-11 · Cited by 232 · cited 1×
“[38] correctly classified 92.”
Cited by
Emerging Wearable Interfaces and Algorithms for Hand Gesture Recognition: A Survey
Jiang, S., Kang, P., Song, X., Lo, B., & Shull, P. (2022) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3078190 · Cited by 270
Self-citationA review of the key technologies for sEMG-based human-robot interaction systems
Li, K., Zhang, J., Wang, L., Zhang, M., Li, J., & Bao, S. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.102074 · Cited by 233
A Wearable Hand Rehabilitation System With Soft Gloves
Chen, X., Gong, L., Wei, L., Yeh, S.-C., Da Xu, L., Zheng, L., & Zou, Z. (2021) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.3010369 · Cited by 194
“neighbor (kNN) [40], dynamic time wrapping (DTW) [26], linear discriminant analysis (LDA) [41], supported vector ma-”
IMU Sensor-Based Hand Gesture Recognition for Human-Machine Interfaces
Kim, M., Cho, J., Lee, S., & Jung, Y. (2019) · Sensors · doi:10.3390/s19183827 · Cited by 169
“If not, the radius of the activated neuron is reduced to ED ( f i , c j ) and a new neuron with a radius of ED ( f i , c j ) and a center point equal to the input feature vector f i is created.”
BackgroundA novel, co-located EMG-FMG-sensing wearable armband for hand gesture recognition
Jiang, S., Gao, Q., Liu, H., & Shull, P. B. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.111738 · Cited by 169
Self-citationHand Gesture Recognition Using EMG-IMU Signals and Deep Q-Networks
Vásconez, J. P., Barona López, L. I., Valdivieso Caraguay, Á. L., & Benalcázar, M. E. (2022) · Sensors · doi:10.3390/s22249613 · Cited by 55
“However, this is still an open research problem [12,13].”
BackgroundSong, X., van de Ven, S. S., Chen, S., Kang, P., Gao, Q., Jia, J., & Shull, P. B. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.811950 · Cited by 47
Self-citation
Metadata
- Authors
- Jiang, S., Lv, B., Guo, W., Zhang, C., Wang, H., Sheng, X., & Shull, P. B.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2018-08
- Volume
- 14
- Issue
- 8
- Pages
- 3376-3385
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2771247593
- Cited by
- 239
- References
- 30
- FWCI
- 13.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.