Distributed Resilient Control for Energy Storage Systems in Cyber–Physical Microgrids
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
As a cyber-physical system (CPS), the security of microgrids (MGs) is threatened by unknown faults and cyberattacks. Most existing distributed control methods for MGs are proposed based on the assumption that secondary controllers of distributed generation units operate in normal conditions. However, the faults and attacks of the distributed control system could lead to a significant impact and consequently influence the security and stability of MGs. In this article, a distributed resilient control strategy for multiple energy storage systems (ESSs) in islanded MGs is proposed to deal with these hidden but lethal issues. By introducing an adaptive technique, a distributed resilient control method is proposed for frequency/voltage restoration, fair real power sharing, and state-of-charge balancing in MGs with multiple ESSs in abnormal condition. The stability of the proposed method is rigorously proved by Lyapunov methods. The proposed method is validated on test systems developed in OPAL-RT simulator under various cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Godsil, C., & Royle, G. (2001) · Graduate Texts in Mathematics · doi:10.1007/978-1-4613-0163-9 · Cited by 8,154
Network reconfiguration in distribution systems for loss reduction and load balancing
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.25627 · Cited by 5,077 · cited 1×
“In this case, a modified IEEE 33-bus distribution network in [43] is used to test the proposed distributed resilient control method in a larger scale power network.”
MethodGuerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075 · cited 3×
“Remark 1: In this article, the framework and notions from hierarchical control of MG systems are followed [9]–[12].”
BackgroundControl of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723 · cited 1×
“The inner control loops of primary control are developed based on [42].”
BackgroundNetwork Reconfiguration in Distribution Systems for Loss Reduction and Load Balancing
Baran, M. E., & Wu, F. F. (1989) · IEEE Power Engineering Review · doi:10.1109/mper.1989.4310642 · Cited by 3,350
Attack Detection and Identification in Cyber-Physical Systems
Pasqualetti, F., Dorfler, F., & Bullo, F. (2013) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2013.2266831 · Cited by 2,109 · cited 2×
“A sophisticated form of faults or attacks on the secondary controller can be modeled [17], [30] by”
BackgroundA secure control framework for resource-limited adversaries
Teixeira, A., Shames, I., Sandberg, H., & Johansson, K. H. (2015) · Automatica · doi:10.1016/j.automatica.2014.10.067 · Cited by 1,187 · cited 1×
“Attacks may be performed over a significant number of attack points in a coordinated fashion [40], which is usually have an intent or objective to fulfill.”
BackgroundGuerrero, J. M., Matas, J., Garcia de Vicuna, L., Castilla, M., & Miret, J. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.892621 · Cited by 1,085
Distributed Secondary Control for Islanded Microgrids—A Novel Approach
Shafiee, Q., Guerrero, J. M., & Vasquez, J. C. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2259506 · Cited by 1,069 · cited 2×
“The typical droop control equations are represented as follows [9], [10]:”
Secondary Frequency and Voltage Control of Islanded Microgrids via Distributed Averaging
Simpson-Porco, J. W., Shafiee, Q., Dorfler, F., Vasquez, J. C., Guerrero, J. M., & Bullo, F. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2436879 · Cited by 974 · cited 4×
“…yields As discussed in [1] and [39], the frequency and voltage of each ESS can be controlled in the secondary level by ˙ ω i ( t It is noted that voltage control is considered in this article, since there is a tradeoff relationship between voltage restoration and reactive power sharing [11], [12].”
BackgroundInfluentialLu, X., Sun, K., Guerrero, J. M., Vasquez, J. C., & Huang, L. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2279374 · Cited by 752 · cited 2×
“By measuring the power output and considering the charging and discharging efficiency of the i th ESS, the SoC or energy level can be estimated by [13]–[15]: where C Ei and SoC i,t = 0 are the capacity (kWh) and initial SoC of the i th ESS.”
BackgroundSmart Grids: A Cyber–Physical Systems Perspective
Yu, X., & Xue, Y. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2503119 · Cited by 717 · cited 1×
“Then another coordinated node attack δ(t) = [2, 2, 2, 2] (Stealth Attack-2) occurs in t = 30 s.”
BackgroundGuo, F., Wen, C., Mao, J., & Song, Y.-D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2379211 · Cited by 678 · cited 1×
“It is noted that voltage control is considered in this article, since there is a tradeoff relationship between voltage restoration and reactive power sharing [11], [12].”
BackgroundSelf-citationA systems and control perspective of CPS security
Dibaji, S. M., Pirani, M., Flamholz, D. B., Annaswamy, A. M., Johansson, K. H., & Chakrabortty, A. (2019) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2019.04.011 · Cited by 559 · cited 2×
“In existing works, the defense mechanisms can be characterized as three categories [22], [23]: 1) prevention : to postpone the onset of an attack, 2) resilience : to tolerate the maximum impact of the attack and operate as closely to the normal state as possible, and 3) attack detection and…”
BackgroundSecondary control of microgrids based on distributed cooperative control of multi‐agent systems
Bidram, A., Davoudi, A., Lewis, F. L., & Qu, Z. (2013) · IET Generation, Transmission & Distribution · doi:10.1049/iet-gtd.2012.0576 · Cited by 541 · cited 2×
“Inthesecondarylevel forSoCbalancing,therealpoweroutputofeachESScanbe controlledby The nominal set-points ω nom i and V nom i are adjusted by the secondary control as follows [39]: where u ωi ( t ) , u Ei ( t ) , and u Vi ( t ) are control inputs to be designed.”
BackgroundMethodControl Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454 · cited 2×
“In the physical layer, energy storage systems (ESSs) are widely integrated to mitigate the power fluctuations of renewable energy sources (RESs) and provide grid ancillary services [4]–[6].”
BackgroundMethodOn the Performance Degradation of Cyber-Physical Systems Under Stealthy Integrity Attacks
Mo, Y., & Sinopoli, B. (2016) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2015.2498708 · Cited by 410
Ding, L., Han, Q.-L., & Zhang, X.-M. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2884494 · Cited by 358 · cited 1×
“In the cyber layer, to enhance the flexibility and reliability of MG systems, the networked and distributed control theory has been widely applied, with realization on multiagent systems and peer-to-peer communications [7], [8].”
BackgroundDeng, C., & Yang, G.-H. (2019) · Automatica · doi:10.1016/j.automatica.2019.01.013 · Cited by 354 · cited 2×
“3) By introducing an adaptive gain, which can be viewed as the adaptive version of the σ-modification method in [35] and [36], a distributed resilient controller avoiding the”
BackgroundMethodSelf-citation(2014) · IEEE Control Systems · doi:10.1109/mcs.2014.2350571 · Cited by 344 · cited 2×
“M ICROGRIDS (MGs) are developing toward cyber– physical systems (CPSs), which consist of electriccoupled physical systems and communication-coupled cyber systems [1]–[3].”
BackgroundDetection of False-Data Injection Attacks in Cyber-Physical DC Microgrids
Beg, O. A., Johnson, T. T., & Davoudi, A. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2656905 · Cited by 297 · cited 2×
“Particularly, the control and communication devices, which have network access are vulnerable to cyber-attacks [25], [26].”
BackgroundMethodDistributed Cooperative Optimal Control of DC Microgrids With Communication Delays
Ding, L., Han, Q.-L., Wang, L. Y., & Sindi, E. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2799239 · Cited by 295 · cited 1×
“In addition, a quantity of research has been conducted to investigated communication issues and mitigation methods for MG systems, such as communication noise [32], delays [33], and packet loss [34].”
BackgroundA Stealth Cyber-Attack Detection Strategy for DC Microgrids
Sahoo, S., Mishra, S., Peng, J. C., & Dragičević, T. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2879886 · Cited by 268 · cited 5×
“The above coordinated note attacks belong to stealth attacks, as discussed in [29].”
BackgroundInfluentialDistributed Noise-Resilient Secondary Voltage and Frequency Control for Islanded Microgrids
Dehkordi, N. M., Baghaee, H. R., Sadati, N., & Guerrero, J. M. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2834951 · Cited by 214 · cited 1×
“In addition, a quantity of research has been conducted to investigated communication issues and mitigation methods for MG systems, such as communication noise [32], delays [33], and packet loss [34].”
BackgroundCyber Security in Control of Grid-Tied Power Electronic Converters—Challenges and Vulnerabilities
Sahoo, S., Dragičević, T., & Blaabjerg, F. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2953480 · Cited by 194 · cited 2×
“Inspired by the previous research [25]–[31], the test cases are categorized single node faults/attacks as in Cases 1 and 2, and coordinated node attacks in Cases 3 and 4.”
MethodSynchrony in Networked Microgrids Under Attacks
Abhinav, S., Modares, H., Lewis, F. L., Ferrese, F., & Davoudi, A. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2721382 · Cited by 187 · cited 7×
“In [30], an observer-based control with confidence and trust factors is proposed to achieve frequency/voltage restoration under cyber attacks.”
BackgroundInfluentialBibliographical review on cyber attacks from a control oriented perspective
Sánchez, H. S., Rotondo, D., Escobet, T., Puig, V., & Quevedo, J. (2019) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2019.08.002 · Cited by 176 · cited 2×
“In existing works, the defense mechanisms can be characterized as three categories [22], [23]: 1) prevention : to postpone the onset of an attack, 2) resilience : to tolerate the maximum impact of the attack and operate as closely to the normal state as possible, and 3) attack detection and…”
BackgroundA Reference Model of Information Assurance & Security
Cherdantseva, Y., & Hilton, J. (2013) · 2013 International Conference on Availability, Reliability and Security · doi:10.1109/ares.2013.72 · Cited by 175 · cited 1×
“Regarding the security of CPSs, there are three important aspects to be protected: confidentiality, integrity, and availability [21].”
BackgroundWang, Y., Nguyen, T. L., Xu, Y. H., Li, Z., Tran, Q. T., & Caire, R. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2019.2936179 · Cited by 161 · cited 2×
“M ICROGRIDS (MGs) are developing toward cyber– physical systems (CPSs), which consist of electriccoupled physical systems and communication-coupled cyber systems [1]–[3].”
BackgroundSelf-citationAggregated Energy Storage for Power System Frequency Control: A Finite-Time Consensus Approach
Wang, Y., Xu, Y. H., Tang, Y. K., Liao, K., Syed, M. H., Guilló-Sansano, E., & Burt, G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2833877 · Cited by 157 · cited 3×
“Real-time test results by using the existing method in [15].”
MethodInfluentialSelf-citationResilient and Cybersecure Distributed Control of Inverter-Based Islanded Microgrids
Bidram, A., Poudel, B., Damodaran, L., Fierro, R., & Guerrero, J. M. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2941748 · Cited by 125
Consensus Control for Energy Storage Systems
Khazaei, J., & Miao, Z. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2624144 · Cited by 103 · cited 1×
“Distributed SoC balancing of multiple ESSs has been proposed by using linear consensus algorithms [4], and nonlinear methods to improve the performance [14], [16].”
MethodCai, H. G., & Hu, G. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2601904 · Cited by 97
Wang, Y., Syed, M. H., Guilló-Sansano, E., Xu, Y. H., & Burt, G. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2019.2957010 · Cited by 95 · cited 1×
“In the cyber layer, to enhance the flexibility and reliability of MG systems, the networked and distributed control theory has been widely applied, with realization on multiagent systems and peer-to-peer communications [7], [8].”
BackgroundSelf-citationResilience Analysis of DC Microgrids Under Denial of Service Threats
Liu, J., Lu, X., & Wang, J. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2897499 · Cited by 87 · cited 1×
“Disruption attacks will cause denial of use of the information, known as denial-of-service (DoS) attack [24].”
BackgroundIntrusion Detection in Distributed Frequency Control of Isolated Microgrids
Lu, L.-Y., Liu, H. J., Zhu, H., & Chu, C. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2906573 · Cited by 83 · cited 1×
“In [28], distributed secondary control of islanded MGs is achieved by primal-dual algorithm, and model-based anomaly detection and”
MethodZhang, R., & Hredzak, B. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2896032 · Cited by 82 · cited 2×
“It should be noted that the dynamics involved in frequency and voltage restoration is much faster than that of SoC balancing process [16].”
BackgroundMethodDistributed Screening of Hijacking Attacks in DC Microgrids
Sahoo, S., Peng, J. C., Mishra, S., & Dragičević, T. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2957071 · Cited by 79 · cited 1×
“For example, if the secondary control is implemented on host computers or embedded systems, both the control signals and measured system states could be manipulated on the devices and during the data transmission process [3], [27].”
BackgroundDual-Consensus-Based Distributed Frequency Control for Multiple Energy Storage Systems
Xing, L., Mishra, Y., Tian, Y., Ledwich, G. F., Su, H., Peng, C., & Fei, M. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2904075 · Cited by 65 · cited 1×
“In the physical layer, energy storage systems (ESSs) are widely integrated to mitigate the power fluctuations of renewable energy sources (RESs) and provide grid ancillary services [4]–[6].”
BackgroundDeng, C. (2019) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2019.2944254 · Cited by 60 · cited 1×
“[44] : If ˆ a i ( 0 ) > ˆ b i ( 0 ) and ˆ c i ( 0 ) > ˆ d i ( 0 ) > 0, then ˆ a i ( t ) > ˆ b i ( t ) ≥ 0 and ˆ c i ( t ) > ˆ d i ( t ) ≥ 0 for all t > t 0 .”
Self-citationRobust Consensus-Based Distributed Energy Management for Microgrids With Packet Losses Tolerance
Duan, J., & Chow, M. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2921231 · Cited by 57 · cited 1×
“In addition, a quantity of research has been conducted to investigated communication issues and mitigation methods for MG systems, such as communication noise [32], delays [33], and packet loss [34].”
Background
Cited by
A Survey of Cyber Attacks on Cyber Physical Systems: Recent Advances and Challenges
Duo, W., Zhou, M., & Abusorrah, A. (2022) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2022.105548 · Cited by 589
Chen, P., Liu, S., Chen, B., & Yu, L. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3142087 · Cited by 120
Chen, L., Liao, Z., & Ma, X. (2020) · IEEE Access · doi:10.1109/access.2020.3036644 · Cited by 19
Metadata
- Authors
- Deng, C., Wang, Y., Wen, C., Xu, Y., & Lin, P.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2021-02
- Volume
- 17
- Issue
- 2
- Pages
- 1331-1341
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W3010993064
- Cited by
- 215
- References
- 41
- FWCI
- 13.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.