The DOI matches its Crossref record.
Monoion oscillator as potential ultimate laser frequency standard
Abstract
An individual atomic ion localized in the center of a small Paul RF quadrupole trap has potential as an ultimate laser frequency standard because the ion may be brought to `a state of complete rest in free space' by sideband cooling. As a consequence, all Doppler shifts vanish, `Free Space' is approximated in so far as the electric trapping field vanishes in the center of the trap and there is no Stark effect. Neither need there be a Zeeman effect as magnetic fields may be controlled down to the microgauss range. There is also no transit time broadening. Minute laser powers provided by harmonic generators suffice for saturation of optical transitions as strongly focused beams may be used. A million-fold atomic amplification of the single-ion fluorescence from a metastable level may bring resolutions of 1 part in 1018within reach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
The quantum-jump approach to dissipative dynamics in quantum optics
Plenio, M. B., & Knight, P. L. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.101 · Cited by 1,515
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Entangled states of trapped atomic ions
Blatt, R., & Wineland, D. (2008) · Nature · doi:10.1038/nature07125 · Cited by 1,188
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Toward Heisenberg-Limited Spectroscopy with Multiparticle Entangled States
Leibfried, D., Barrett, M. D., Schaetz, T., Britton, J., Chiaverini, J., Itano, W. M., Jost, J. D., Langer, C., & Wineland, D. J. (2004) · Science · doi:10.1126/science.1097576 · Cited by 661
Spectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
The semiclassical theory of laser cooling
Stenholm, S. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.699 · Cited by 616
Ultrastable Optical Clock with Neutral Atoms in an Engineered Light Shift Trap
Katori, H., Takamoto, M., Pal’chikov, V. G., & Ovsiannikov, V. D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.173005 · Cited by 572
Nobel Lecture: Superposition, entanglement, and raising Schrödinger’s cat
Wineland, D. J. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1103 · Cited by 503
Nuclear laser spectroscopy of the 3.5 eV transition in Th-229
Peik, E., & Tamm, C. (2003) · Europhysics Letters (EPL) · doi:10.1209/epl/i2003-00210-x · Cited by 435
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. (2004) · Science · doi:10.1126/science.1105497 · Cited by 301
Single-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Optical lattice clocks and quantum metrology
Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.45 · Cited by 281
Standards of Time and Frequency at the Outset of the 21st Century
Diddams, S. A., Bergquist, J. C., Jefferts, S. R., & Oates, C. W. (2004) · Science · doi:10.1126/science.1102330 · Cited by 275
Quantum jumps in atomic systems
Zoller, P., Marte, M., & Walls, D. F. (1987) · Physical Review A · doi:10.1103/physreva.35.198 · Cited by 268
Sub-dekahertz Ultraviolet Spectroscopy of199Hg+
Rafac, R. J., Young, B. C., Beall, J. A., Itano, W. M., Wineland, D. J., & Bergquist, J. C. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2462 · Cited by 266
Single-Atom Laser Spectroscopy. Looking for Dark Periods in Fluorescence Light
Cohen-Tannoudji, C., & Dalibard, J. (1986) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/1/9/004 · Cited by 254
State readout of a trapped ion qubit using a trap-integrated superconducting photon detector
Todaro, S. L., Verma, V. B., McCormick, K. C., Allcock, D. T. C., Mirin, R. P., Wineland, D. J., Nam, S. W., Wilson, A. C., Leibfried, D., & Slichter, D. H. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.010501 · Cited by 98
“sition with laser light and observing the presence or absence of ion fluorescence [5].”
BackgroundInfluentialMagic Wavelength to Make Optical Lattice Clocks Insensitive to Atomic Motion
Katori, H., Hashiguchi, K., Il’inova, E. Y., & Ovsiannikov, V. D. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.153004 · Cited by 67
A perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40
Longitudinal Ramsey spectroscopy of atoms for continuous operation of optical clocks
Katori, H. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac0e16 · Cited by 31
Metadata
- Authors
- Dehmelt, H. G.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 1982-06
- Volume
- IM-31
- Issue
- 2
- Pages
- 83-87
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2054048084
- Cited by
- 323
- References
- 0
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.