CoChat

The Stability of an Optical Clock Laser Transferred to the Interrogation Oscillator for a Cs Fountain

Open access
Lipphardt, B., Grosche, G., Sterr, U., Tamm, C., Weyers, S., Schnatz, H. · 2009 · IEEE Transactions on Instrumentation and Measurement
Cited by 54

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We stabilize a microwave oscillator at 9.6 GHz to an optical clock laser at 344 THz by using a fiber-based femtosecond laser frequency comb as a transfer oscillator. With a second frequency comb, we independently measure the instability of the microwave source with respect to another optical clock laser frequency at 456 THz. The total fractional frequency instability of this optic-to-microwave and microwave-to-optic conversion resulted in an Allan deviation sigmayof 1.2 times 10-14at 1 s averaging time (bandwidth of 50 kHz). The residual phase noise density is -97 dBc/Hz at a 10 Hz offset from the 9.6 GHz carrier. Replacing the existing quartz-based interrogation oscillator of the Physikalisch-Technische Bundesanstalt (PTB) caesium fountain CSF1 with this optically stabilized microwave source will reduce the instability contribution due to the Dick effect from the 10-13level at 1 s averaging time to an insignificant level at the current status of CSF1. Therefore, this new microwave source can be an alternative to cryogenic sapphire-loaded cavity oscillators to overcome the limitations of state-of-the-art quartz oscillators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2008.2007051

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 54

Metadata

Authors
Lipphardt, B., Grosche, G., Sterr, U., Tamm, C., Weyers, S., & Schnatz, H.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2009-04
Volume
58
Issue
4
Pages
1258-1262
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W2097517636
Cited by
54
References
1
FWCI
3.67
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Stability of an Optical Clock Laser Transferred to the Interrogation Oscillator for a Cs Fountain. https://app.cochat.ai/papers/10.1109/tim.2008.2007051
The paper
Lipphardt, B., Grosche, G., Sterr, U., Tamm, C., Weyers, S., & Schnatz, H. (2009). The Stability of an Optical Clock Laser Transferred to the Interrogation Oscillator for a Cs Fountain. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2008.2007051

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.