Feature-Based Neural Network Approach for Oscillometric Blood Pressure Estimation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this paper, we present a novel feature-based neural network (NN) approach for estimation of blood pressure (BP) from wrist oscillometric measurements. Unlike previous methods that use the raw oscillometric waveform envelope (OMWE) as input to the NN, in this paper, we propose to use features extracted from the envelope. The OMWE is mathematically modeled as a sum of two Gaussian functions. The optimum parameters of this model are found by minimizing the least squares error between the model and the OMWE using the Levenberg-Marquardt algorithm and are used as features. Two separate feed-forward NNs (FFNNs) are then designed to estimate the systolic and diastolic BPs using these features. The FFNNs are trained using the resilient backpropagation learning algorithm and tested on a data set of BP measurements recorded from 85 subjects. The performance is then compared with that of the conventional maximum amplitude algorithm, adaptive neuro-fuzzy inference system, and already published NN-based methods. It is found that the proposed approach achieves lower values of mean absolute error and standard deviation of error in the estimation of BP. In addition, the proposed approach has the following advantages: lower complexity with respect to the design parameters, smaller training data set, and lower computational load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
A direct adaptive method for faster backpropagation learning: the RPROP algorithm
Riedmiller, M., & Braun, H. (2002) · IEEE International Conference on Neural Networks · doi:10.1109/icnn.1993.298623 · Cited by 3,917
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Oscillometric determination of diastolic, mean and systolic blood pressure—A numerical model
Forster, F. K., & Turney, D. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138629 · Cited by 104
Cited by
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Self-citationPPG2ABP: Translating photoplethysmogram (PPG) signals to arterial blood pressure (ABP) waveforms
Ibtehaz, N., Mahmud, S., Chowdhury, M. E. H., Khandakar, A., Salman Khan, M., Ayari, M. A., Tahir, A. M., & Rahman, M. S. (2022) · Bioengineering · doi:10.3390/bioengineering9110692 · Cited by 133
Novel methods of testing and calibration of oscillometric blood pressure monitors
Celler, B. G., Argha, A., Le, P. N., & Ambikairajah, E. (2018) · PLOS ONE · doi:10.1371/journal.pone.0201123 · Cited by 28
“Curve fitting can also be supplemented using artificial neural network [22] or fuzzy logic [23] to minimise the MSE.”
Method
Metadata
- Authors
- Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., & Rajan, S.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2011-08
- Volume
- 60
- Issue
- 8
- Pages
- 2786-2796
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2121071670
- Cited by
- 79
- References
- 4
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feature-Based Neural Network Approach for Oscillometric Blood Pressure Estimation. https://app.cochat.ai/papers/10.1109/tim.2011.2123210
- The paper
- Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., & Rajan, S. (2011). Feature-Based Neural Network Approach for Oscillometric Blood Pressure Estimation. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2011.2123210
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.