The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Concentration Measurement of Microliter-Volume Water–Glucose Solutions Using $Q$ Factor of Microwave Sensors
Abstract
A glucose concentration sensor for microliter-volume water-glucose solutions is presented. The proposed sensor is composed of an open-loop microstrip resonator with a dielectric liquid holder (5-25-μL volume) glued onto the gap between the line ends. The resonator is coupled to two microstrip lines forming a two-port network whose S-parameter response provide information about the dielectric properties of the liquid under study. Three versions of the sensor at resonant frequencies between 2 and 7 GHz are presented. The sensors are assessed by measuring the complex permittivity of standard liquids reported in the scientific literature. Models of the sensors are presented, which properly match the experimental results. This paper presents an experimental study of the sensors as glucose concentration retrievers. The main novelty is the use of Q factor and the maximum S21 of the resonance as sensing magnitudes. The dependence of these parameters on the glucose concentration of the solutions obeys almost linear relationships. Good sensitivities have been obtained for the proposed sensors, which are coherent with previous works by other authors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The frequency range selected in this paper is interesting, because the attenuation lengths for the tissues of the human skin (epidermis + dermis) vary roughly from ∼4 mm to ∼3 cm in this band [22],”
BackgroundCaduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., & Feldman, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.031 · Cited by 155 · cited 1×
“troscopy [25], transmission line techniques [26], or microwave”
BackgroundModeling the glucose sensor error
Facchinetti, A., Del Favero, S., Sparacino, G., Castle, J. R., Ward, W. K., & Cobelli, C. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2284023 · Cited by 130
Cited by
Omer, A. E., Shaker, G., Safavi-Naeini, S., Kokabi, H., Alquié, G., Deshours, F., & Shubair, R. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72114-3 · Cited by 283
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
“The dependency of glucose concentration to the quality factor of an open-loop resonator was recently investigated by measuring the Q factor for different glucose concentration in aqueous solutions [180], blood plasma solutions [181] and on 352 human tongues [182].”
Method
Metadata
- Authors
- Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Avila-Navarro, E., & Sabater-Navarro, J. M.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2019-07
- Volume
- 68
- Issue
- 7
- Pages
- 2621-2634
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2891262528
- Cited by
- 177
- References
- 3
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Concentration Measurement of Microliter-Volume Water–Glucose Solutions Using $Q$ Factor of Microwave Sensors. https://app.cochat.ai/papers/10.1109/tim.2018.2866743
- The paper
- Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Avila-Navarro, E., & Sabater-Navarro, J. M. (2019). Concentration Measurement of Microliter-Volume Water–Glucose Solutions Using $Q$ Factor of Microwave Sensors. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2018.2866743
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.