A CMOS Receiver–TDC Chip Set for Accurate Pulsed TOF Laser Ranging
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
An integrated receiver-time-to-digital converter (TDC) chip set is developed for pulsed time-of-flight (TOF) laser rangefinding. The receiver detects the current pulse from the optical detector and produces a timing mark for the TDC. The receiver uses time mode walk error compensation scheme achieving <; ±2.5-mm residual timing-walk error within a dynamic range of ~1:40 000. The multichannel TDC measures the time position, width, and rise time of the echo pulses simultaneously with ~10-ps precision. Both chips are manufactured in 0.35-μm complementary metal-oxide-semiconductor (CMOS) technology. The functionality of the chip set was demonstrated in a laser radar platform using 12 W and 3-ns optical pulses produced by a laser diode (LD). Measurement accuracy of ~ ±3 mm was achieved with noncooperative targets at a distance range of a few tens of meters within an amplitude range of received echoes of 1:40 000.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wideband Receiver for a Three-Dimensional Ranging LADAR System
Ngo, T.-H., Kim, C.-H., Kwon, Y. J., Ko, J. S., Kim, D.-B., & Park, H.-H. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2215800 · Cited by 68 · cited 1×
“This work [14] [23] [24] [25] [26] [27]”
A Linear-Mode LiDAR Sensor Using a Multi-Channel CMOS Transimpedance Amplifier Array
Hong, C., Kim, S.-H., Kim, J.-H., & Park, S. M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2852794 · Cited by 64 · cited 2×
“where a 1-D or 2-D array of detectors is located on the focal plane of the receiver optics [23].”
BackgroundA Linear Dynamic Range Receiver with Timing Discrimination for Pulsed TOF Imaging LADAR Application
Zheng, H., Ma, R., Liu, M., & Zhu, Z. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2826860 · Cited by 46 · cited 1×
“In [25]–[26], the timing accuracy is less than ±75 mm within a dynamic range of approximately <1:10 000, whereas millimeter-level accuracy was achieved over a wider dynamic range in the present study, however at a cost of somewhat higher noise.”
Background
Cited by
A CMOS AFE With 37-nA rms Input-Referred Noise and Marked 96-dB Timing DR for Pulsed LiDAR
Li, K., Guo, J., & Zhao, Y. (2022) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2022.3181133 · Cited by 14
“For the single-shot measurement application scenarios, the width [18], [22] or slew rate [23] of the echo pulse, or both of them [12], [24] can be measured and utilized to compensate for the walk”
BackgroundMethodInfluentialA Current-Mode Optoelectronic Receiver IC for Short-Range LiDAR Sensors in 180 nm CMOS
Hu, Y., Joo, J.-E., Zhang, X., Chon, Y., Choi, S., Lee, M.-J., & Park, S.-M. (2023) · Photonics · doi:10.3390/photonics10070746 · Cited by 6
A CMOS Integrator-Based Clock-Free Time-to-Digital Converter for Home-Monitoring LiDAR Sensors
He, Y., & Park, S. M. (2022) · Sensors · doi:10.3390/s22020554 · Cited by 5
Metadata
- Authors
- Kurtti, S., Jansson, J.-P., & Kostamovaara, J.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2020-05
- Volume
- 69
- Issue
- 5
- Pages
- 2208-2217
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2946304063
- Cited by
- 64
- References
- 3
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).