Abstract

Early diagnosis of interturn short circuit (ITSC) fault is essential to prevent catastrophic electrical machine failures. Along with the detection, locating the faulty winding at its incipient stage is also critical to reduce the outage duration and operation losses. This article proposes a practical method to detect the ITSC fault and locate the faulty winding in permanent magnet synchronous motors (PMSMs) through stray magnetic flux monitoring. It is shown that relying on the fundamental stray flux component can potentially underperform at certain operating conditions leading to fault negative error. To compensate this shortcoming, the third harmonic component of stray flux is comprehensively analyzed and proposed as a complementary ITSC fault indicator. Furthermore, its reliability over the wide range of motor operation is verified to eliminate potential fault negative errors. It is also shown that the proposed method is independent of the fault severity which is a major advantage for practical applications. The findings are supported through 2-D-FEA PMSM drive system simulations and experiments under two different fault severity cases.

Overview

Integrity signals

Registry

Crossref · 10.1109/tim.2020.3013128

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 1

  1. 2020, DRV425 Fluxgate Magnetic-Field Sensor Datasheet

Cited by

Metadata

Authors
Gurusamy, V., Bostanci, E., Li, C., Qi, Y., & Akin, B.
Affiliations
The University of Texas at Dallas (US)
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2021
Volume
70
Pages
1-11
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W3046256313
Cited by
93
References
24
Citations by year
2026: 8 · 2025: 18 · 2024: 15 · 2023: 16 · 2022: 22 · 2021: 14
FWCI
4.47
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Instrumentation and Measurement (publishedVersion)
  • OpenMETU (Middle East Technical University) (submittedVersion, cc-by-nc-nd)
Funders
Texas Instruments Inc., through the Semiconductor Research Corporation/Texas Analog Center of Excellence (SRC/TxACE) Center (Task 2810.016)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
Keywords
inter-turn short-circuit fault, permanent magnet synchronous motor, fault diagnosis, fault location, winding fault detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.