A Stray Magnetic Flux-Based Robust Diagnosis Method for Detection and Location of Interturn Short Circuit Fault in PMSM
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Early diagnosis of interturn short circuit (ITSC) fault is essential to prevent catastrophic electrical machine failures. Along with the detection, locating the faulty winding at its incipient stage is also critical to reduce the outage duration and operation losses. This article proposes a practical method to detect the ITSC fault and locate the faulty winding in permanent magnet synchronous motors (PMSMs) through stray magnetic flux monitoring. It is shown that relying on the fundamental stray flux component can potentially underperform at certain operating conditions leading to fault negative error. To compensate this shortcoming, the third harmonic component of stray flux is comprehensively analyzed and proposed as a complementary ITSC fault indicator. Furthermore, its reliability over the wide range of motor operation is verified to eliminate potential fault negative errors. It is also shown that the proposed method is independent of the fault severity which is a major advantage for practical applications. The findings are supported through 2-D-FEA PMSM drive system simulations and experiments under two different fault severity cases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The FFT analysis of the axial flux signal is also very effective for detecting ITSCs in stator winding of PMSMs.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [54]
Citations
Cites
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382 · cited 2×
“motor faults, short circuit fault in stator is a very common one which constitutes 20%–30% of the most commonly observed faults [1]–[3], [6].”
BackgroundCurrent Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139 · cited 2×
“Though fast Fourier transform (FFT) is the most commonly used technique due to the less computational effort [8], [9], there are other techniques like short-time Fourier transform (STFT) [10] which converts time-domain signal to frequency domain by splitting signals into multiple segments to check for variation in fre…”
BackgroundMethodCause and analysis of stator and rotor failures in three-phase squirrel-cage induction motors
Bonnett, A. H., & Soukup, G. C. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.148460 · Cited by 593
Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512 · cited 2×
“Though fast Fourier transform (FFT) is the most commonly used technique due to the less computational effort [8], [9], there are other techniques like short-time Fourier transform (STFT) [10] which converts time-domain signal to frequency domain by splitting signals into multiple segments to check for variation in fre…”
MethodGrubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490 · cited 2×
“motor faults, short circuit fault in stator is a very common one which constitutes 20%–30% of the most commonly observed faults [1]–[3], [6].”
BackgroundCause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors
Bonnett, A. K., & Soukup, G. C. (2002) · Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference · doi:10.1109/papcon.1991.239667 · Cited by 489 · cited 1×
“which further develops into catastrophic stator faults [5] like phase to phase short circuit fault or phase to ground short cir-”
BackgroundMaking the Case for Electrified Transportation
Bilgin, B., Magne, P., Malysz, P., Yang, Y., Pantelic, V., Preindl, M., Korobkine, A., Jiang, W., Lawford, M., & Emadi, A. (2015) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2015.2437338 · Cited by 455 · cited 1×
“ment of wide bandgap devices [4], high dv/dt increases the electrical stress one order of magnitude.”
BackgroundDetection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394 · cited 2×
“A method to locate the faulty coil was proposed in [19]”
BackgroundMethodHenao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361 · cited 2×
“It has been observed in [16] that the stray flux has a high signal to noise ratio and good sensitivity”
BackgroundIncreased Efficiency Versus Increased Reliability
Bonnett, A., & Yung, C. (2008) · IEEE Industry Applications Magazine · doi:10.1109/mia.2007.909802 · Cited by 359
Research works printed but not linked: 1
- 2020, DRV425 Fluxgate Magnetic-Field Sensor Datasheet
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“In [54], a novel and robust stray flux analysis for ITSC detection for PMSM is proposed.”
MethodMahmoudi, A., Jlassi, I., Cardoso, A. J. M., Yahia, K., & Sahraoui, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3109514 · Cited by 106
On Bayesian Optimization-Based Residual CNN for Estimation of Inter-Turn Short Circuit Fault in PMSM
Song, Q., Wang, M., Lai, W., & Zhao, S. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3207181 · Cited by 106
“…analysis, which diagnoses the fault via obtaining particular current features through diverse means, for instance, symmetrical component analysis, fast Fourier transform, short-time Fourier transform, wavelet analysis, Hilbert–Huang transform, and Wigner–Ville distributions [14], [15], [16].”
BackgroundWei, D., Liu, K., Hu, W. J., Peng, X., Chen, Y., & Ding, R. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3167164 · Cited by 92
“[7], zero-sequence voltage components [8], [19], stray magnetic flux [20], vibration signal [21], etc.”
BackgroundRecent Trends in Magnetic Sensors and Flux-Based Condition Monitoring of Electromagnetic Devices
Gurusamy, V., Capolino, G., Akin, B., Henao, H., Romary, R., & Pusca, R. (2022) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2022.3174804 · Cited by 73
Self-citation
Metadata
- Authors
- Gurusamy, V., Bostanci, E., Li, C., Qi, Y., & Akin, B.
- Affiliations
- The University of Texas at Dallas (US)
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2021
- Volume
- 70
- Pages
- 1-11
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W3046256313
- Cited by
- 93
- References
- 24
- Citations by year
- 2026: 8 · 2025: 18 · 2024: 15 · 2023: 16 · 2022: 22 · 2021: 14
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- OpenMETU (Middle East Technical University) (submittedVersion, cc-by-nc-nd)
- Funders
- Texas Instruments Inc., through the Semiconductor Research Corporation/Texas Analog Center of Excellence (SRC/TxACE) Center (Task 2810.016)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- inter-turn short-circuit fault, permanent magnet synchronous motor, fault diagnosis, fault location, winding fault detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.