Dual-Frequency Microwave Resonant Sensor to Detect Noninvasive Glucose-Level Changes Through the Fingertip
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
In this article, which is a fundamental step in an underway research, a microwave resonant sensor at two resonance frequencies of 5.5 and 8.5 GHz (in order to increase the accuracy of the application) with a quality factor of 180 and 106, for blood glucose level monitoring is designed, fabricated, and tested by users' fingertips. In this study, 11 volunteers were tested invasively (using a glucometer) and noninvasively (using the proposed glucose resonant sensor) with range of glucose-level changes from 89 to 262 mg/dL. For this range of glucose-level changes, the frequency detection resolution is 3.53 and 3.58 MHz/ (mg/dL), respectively. The results of the experiments are relatively well matched; so that compared to the glucometer device, the proposed sensor shows a maximum measurement error of about 3% to detect glucose levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Toward Flexible Surface‐Enhanced Raman Scattering (SERS) Sensors for Point‐of‐Care Diagnostics
Xu, K., Zhou, R., Takei, K., & Hong, M. (2019) · Advanced Science · doi:10.1002/advs.201900925 · Cited by 633
Wearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Progress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Omer, A. E., Shaker, G., Safavi-Naeini, S., Kokabi, H., Alquié, G., Deshours, F., & Shubair, R. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72114-3 · Cited by 283 · cited 4×
“simple fabrication in an electrically small size; and as stated in article [57], a portable version of the proposed microwave biosensor can be developed for continuous monitoring of blood glucose in diabetic patients by replacing the vector network analyzer (VNA) with a low-cost, low-frequency radar, and its realizati…”
Influential7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221 · cited 1×
“In the last few decades, many efforts have been taken to develop noninvasive blood glucose concentration monitoring devices; but on the other hand, many presented technologies based on noninvasive have not been accurate enough, have not been able to work for a longtime, and they have not reached the stage of wide comm…”
EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing
Mehrotra, P., Chatterjee, B., & Sen, S. (2019) · Sensors · doi:10.3390/s19051013 · Cited by 219 · cited 1×
“Noninvasive blood glucose concentration monitoring devices are recommended by research groups and companies with the aim of providing a simple, cost-effective, painless, and convenient device for measuring glucose levels continuously and for smart healthcare at-home devices [5], [6].”
Metadata
- Authors
- Kiani, S., Rezaei, P., & Fakhr, M.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2021
- Volume
- 70
- Pages
- 1-8
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W3132704342
- Cited by
- 220
- References
- 49
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual-Frequency Microwave Resonant Sensor to Detect Noninvasive Glucose-Level Changes Through the Fingertip. https://app.cochat.ai/papers/10.1109/tim.2021.3052011
- The paper
- Kiani, S., Rezaei, P., & Fakhr, M. (2021). Dual-Frequency Microwave Resonant Sensor to Detect Noninvasive Glucose-Level Changes Through the Fingertip. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2021.3052011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.