Dual-Frequency Microwave Resonant Sensor to Detect Noninvasive Glucose-Level Changes Through the Fingertip
The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
In this article, which is a fundamental step in an underway research, a microwave resonant sensor at two resonance frequencies of 5.5 and 8.5 GHz (in order to increase the accuracy of the application) with a quality factor of 180 and 106, for blood glucose level monitoring is designed, fabricated, and tested by users' fingertips. In this study, 11 volunteers were tested invasively (using a glucometer) and noninvasively (using the proposed glucose resonant sensor) with range of glucose-level changes from 89 to 262 mg/dL. For this range of glucose-level changes, the frequency detection resolution is 3.53 and 3.58 MHz/ (mg/dL), respectively. The results of the experiments are relatively well matched; so that compared to the glucometer device, the proposed sensor shows a maximum measurement error of about 3% to detect glucose levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Enzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Toward Flexible Surface‐Enhanced Raman Scattering (SERS) Sensors for Point‐of‐Care Diagnostics
Xu, K., Zhou, R., Takei, K., & Hong, M. (2019) · Advanced Science · doi:10.1002/advs.201900925 · Cited by 633
Wearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Progress and challenges in fabrication of wearable sensors for health monitoring
Nasiri, S., & Khosravani, M. R. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112105 · Cited by 295 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Omer, A. E., Shaker, G., Safavi-Naeini, S., Kokabi, H., Alquié, G., Deshours, F., & Shubair, R. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-72114-3 · Cited by 283 · cited 4×
“simple fabrication in an electrically small size; and as stated in article [57], a portable version of the proposed microwave biosensor can be developed for continuous monitoring of blood glucose in diabetic patients by replacing the vector network analyzer (VNA) with a low-cost, low-frequency radar, and its realizati…”
Influential7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221 · cited 1×
“In the last few decades, many efforts have been taken to develop noninvasive blood glucose concentration monitoring devices; but on the other hand, many presented technologies based on noninvasive have not been accurate enough, have not been able to work for a longtime, and they have not reached the stage of wide comm…”
EM-Wave Biosensors: A Review of RF, Microwave, mm-Wave and Optical Sensing
Mehrotra, P., Chatterjee, B., & Sen, S. (2019) · Sensors · doi:10.3390/s19051013 · Cited by 219 · cited 1×
“Noninvasive blood glucose concentration monitoring devices are recommended by research groups and companies with the aim of providing a simple, cost-effective, painless, and convenient device for measuring glucose levels continuously and for smart healthcare at-home devices [5], [6].”
Baghelani, M., Abbasi, Z., Daneshmand, M., & Light, P. E. (2020) · Scientific Reports · doi:10.1038/s41598-020-69547-1 · Cited by 214 · cited 1×
“But one of the disadvantages of some of these commercial devices is that they are not completely noninvasive, for example, contact lenses or implantable devices and a few others are introduced as semi-invasive devices and in addition, they impose restrictions on the user and are expensive [20].”
Omer, A. E., Shaker, G., Safavi-Naeini, S., Alquie, G., Deshours, F., Kokabi, H., & Shubair, R. M. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038589 · Cited by 185 · cited 1×
“Most past articles and researches in the field of noninvasive glucose level monitoring by resonant sensors have carried out solution-based glucose measurement [61], [62], and very few articles have accomplished real measurements of the glucose concentration changes in the body [63]–[66].”
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Avila-Navarro, E., & Sabater-Navarro, J. M. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2866743 · Cited by 177 · cited 1×
“Most past articles and researches in the field of noninvasive glucose level monitoring by resonant sensors have carried out solution-based glucose measurement [61], [62], and very few articles have accomplished real measurements of the glucose concentration changes in the body [63]–[66].”
Recent advances in noninvasive flexible and wearable wireless biosensors
Salim, A., & Lim, S. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111422 · Cited by 153 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Hanna, J., Bteich, M., Tawk, Y., Ramadan, A. H., Dia, B., Asadallah, F. A., Eid, A., Kanj, R., Costantine, J., & Eid, A. A. (2020) · Science Advances · doi:10.1126/sciadv.aba5320 · Cited by 149 · cited 1×
“Most past articles and researches in the field of noninvasive glucose level monitoring by resonant sensors have carried out solution-based glucose measurement [61], [62], and very few articles have accomplished real measurements of the glucose concentration changes in the body [63]–[66].”
Turgul, V., & Kale, İ. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.03.041 · Cited by 119 · cited 2×
“References [22], [59] have dealt the issue in microwave sensors, which are designed to monitor the blood glucose levels by the user’s fingertip, and factors such as the arrangement of each person’s fingertip which are introduced as irregular lines and grooves of the fingerprint expressing the air gaps between the fing…”
Jang, C., Park, J., Lee, H., Yun, G., & Yook, J. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2984779 · Cited by 116 · cited 1×
“Many studies have consistently suggested promising results and various methods for measuring the EM properties of blood glucose in tissues; for example, split ring resonators [38] and complementary split ring resonators [39], antennas [40]–[42] and filters [43], transmission lines [44] and coaxial [45], implantable de…”
Zhou, H., Hu, D., Yang, C., Chen, C., Ji, J., Chen, M., Chen, Y., Yang, Y. F., & Mu, X. (2018) · Scientific Reports · doi:10.1038/s41598-018-32827-y · Cited by 112 · cited 3×
“In other words, resonance frequency to be shifted due to small changes in the EM properties in a small volume of the SUT.”
InfluentialHuang, S. Y., Omkar, Yoshida, Y., Inda, A. J. G., Chia, X. X., Mu, W. C., Meng, Y. S., & Yu, W. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877691 · Cited by 108 · cited 1×
“Also, these systems allow the users to test their glucose levels without the daily prick of their fingers [25], [26].”
Dautta, M., Alshetaiwi, M., Escobar, J. T., & Tseng, P. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112004 · Cited by 106 · cited 1×
“Many studies have consistently suggested promising results and various methods for measuring the EM properties of blood glucose in tissues; for example, split ring resonators [38] and complementary split ring resonators [39], antennas [40]–[42] and filters [43], transmission lines [44] and coaxial [45], implantable de…”
Peng, B., Lu, J., Balijepalli, A. S., Major, T. C., Cohan, B. E., & Meyerhoff, M. E. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.05.014 · Cited by 103 · cited 1×
“Also, the glucose level in sweat, saliva, breath, and eye tears are much lower than that in blood [21].”
Analysis and Design of a Microwave Coplanar Sensor for Non-Invasive Blood Glucose Measurements
Cebedio, M. C., Rabioglio, L. A., Gelosi, I. E., Ribas, R. A., Uriz, A. J., & Moreira, J. C. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2993182 · Cited by 99
Prabhakaran, A., & Nayak, P. (2019) · ACS Applied Nano Materials · doi:10.1021/acsanm.9b02025 · Cited by 98 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Hassan, R. S., Lee, J., & Kim, S. (2019) · IEEE Antennas and Wireless Propagation Letters · doi:10.1109/lawp.2019.2955176 · Cited by 93 · cited 1×
“to changes in the EM parameters of ISF under the skin, saliva, tears, sweat, urine, blood in the vessels, and so on [24], these types of systems rely mainly on changes in the permittivity (ε) of tissues or target cells.”
Lin, K., Muthukumar, S., & Prasad, S. (2020) · Talanta · doi:10.1016/j.talanta.2020.120810 · Cited by 83 · cited 5×
“In this article, a near-field microwave sensor is presented for noninvasive monitoring of the glucose concentration changes in the ISF under the skin and blood vessels in the fingertip with two resonance frequencies to increase the accuracy and sensitivity in diagnosis.”
InfluentialDesign of an ELC resonator-based reusable RF microfluidic sensor for blood glucose estimation
Govind, G., & Akhtar, M. J. (2020) · Scientific Reports · doi:10.1038/s41598-020-75716-z · Cited by 80
Blood Glucose Level Monitoring Using an FMCW Millimeter-Wave Radar Sensor
Omer, A. E., Safavi‐Naeini, S., Hughson, R. L., & Shaker, G. S. A. (2020) · Remote Sensing · doi:10.3390/rs12030385 · Cited by 78 · cited 1×
“Many studies have consistently suggested promising results and various methods for measuring the EM properties of blood glucose in tissues; for example, split ring resonators [38] and complementary split ring resonators [39], antennas [40]–[42] and filters [43], transmission lines [44] and coaxial [45], implantable de…”
Kandwal, A., Igbe, T., Li, J., Liu, Y., Li, S., Liu, L. W., & Nie, Z. (2020) · Scientific Reports · doi:10.1038/s41598-020-60806-9 · Cited by 76
WGM-Based Sensing of Characterized Glucose- Aqueous Solutions at mm-Waves
Omer, A. E., Gigoyan, S. S., Shaker, G. S. A., & Safavi‐Naeini, S. (2020) · IEEE Access · doi:10.1109/access.2020.2975805 · Cited by 70 · cited 1×
“Also, these systems allow the users to test their glucose levels without the daily prick of their fingers [25], [26].”
Odabashyan, L., Babajanyan, A., Baghdasaryan, Z., Kim, S., Kim, J., Friedman, B., Lee, J., & Lee, K. (2019) · Sensors · doi:10.3390/s19245525 · Cited by 68 · cited 1×
“Most past articles and researches in the field of noninvasive glucose level monitoring by resonant sensors have carried out solution-based glucose measurement [61], [62], and very few articles have accomplished real measurements of the glucose concentration changes in the body [63]–[66].”
Investigation on planar microwave sensors with enhanced sensitivity from microfluidic integration
Sharafadinzadeh, N., Abdolrazzaghi, M., & Daneshmand, M. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.111752 · Cited by 54
Singh, A. K., & Jha, S. K. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2920296 · Cited by 53 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Turgul, V., & Kale, İ. (2017) · Electronics Letters · doi:10.1049/el.2016.4327 · Cited by 52 · cited 5×
“the fingertip; and (8) the time of the last meal that the user has eaten [22], [59].”
InfluentialTseng, C., & Wu, C.-Z. (2020) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2020.2966188 · Cited by 48 · cited 1×
“In [60], it was concluded that if a high field and energy are concentrated uniformly in the sensing area, the errors occurred will be”
Real time monitoring of glucose in whole blood by smartphone
Erenas, M. M., Carrillo-Aguilera, B., Cantrell, K., González-Chocano, S., de Vargas-Sansalvador, I. M. P., de Orbe-Payá, I., & Capitán-Vallvey, L. F. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.024 · Cited by 48 · cited 1×
“Noninvasive blood glucose concentration monitoring devices are recommended by research groups and companies with the aim of providing a simple, cost-effective, painless, and convenient device for measuring glucose levels continuously and for smart healthcare at-home devices [5], [6].”
T-Shaped Patterned Microstrip Line for Noninvasive Continuous Glucose Sensing
Omkar, Yu, W., & Huang, S. Y. (2018) · IEEE Microwave and Wireless Components Letters · doi:10.1109/lmwc.2018.2861565 · Cited by 46
Glucose Levels Detection Using mm-Wave Radar
Omer, A. E., Shaker, G. S. A., Safavi‐Naeini, S., Murray, K. R., & Hughson, R. L. (2018) · IEEE Sensors Letters · doi:10.1109/lsens.2018.2865165 · Cited by 42 · cited 1×
“Many studies have consistently suggested promising results and various methods for measuring the EM properties of blood glucose in tissues; for example, split ring resonators [38] and complementary split ring resonators [39], antennas [40]–[42] and filters [43], transmission lines [44] and coaxial [45], implantable de…”
High $Q$ Microwave Microfluidic Sensor Using a Central Gap Ring Resonator
Hamzah, H., Abduljabar, A. A., & Porch, A. (2020) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2019.2959757 · Cited by 41 · cited 1×
“Various methods for measuring EM properties based on microwave and millimeter waves have been proposed, which can be classified as nonresonant (broadband) [30]–[32] and resonant (narrow band) [33], [34] methods.”
Juan, C. G., García, H. G., Ávila-Navarro, E., Bronchalo, E., Galiano, V., Moreno, Ó., Orozco‐Beltrán, D., & Sabater-Navarro, J. M. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02030-w · Cited by 36 · cited 1×
“Many studies have consistently suggested promising results and various methods for measuring the EM properties of blood glucose in tissues; for example, split ring resonators [38] and complementary split ring resonators [39], antennas [40]–[42] and filters [43], transmission lines [44] and coaxial [45], implantable de…”
Non-invasive blood glucose measurement of 95% certainty by pressure regulated Mid-IR
Chen, J. Y., Zhou, Q., Xu, G., Wang, R. T., Tai, E. G., Xie, L., Qianzhi, Z., Guan, Y., & Huang, X. (2019) · Talanta · doi:10.1016/j.talanta.2019.01.034 · Cited by 35 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
A Non-Invasive Flexible Glucose Monitoring Sensor Using a Broadband Reject Filter
Bteich, M., Hanna, J., Costantine, J., Kanj, R. N., Tawk, Y., Ramadan, A., & Eid, A. A. (2020) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2020.3023053 · Cited by 33 · cited 1×
“Various methods for measuring EM properties based on microwave and millimeter waves have been proposed, which can be classified as nonresonant (broadband) [30]–[32] and resonant (narrow band) [33], [34] methods.”
MICROSTRIP DEFECTED GROUND STRUCTURE FOR DETERMINATION OF BLOOD GLUCOSE CONCENTRATION
Yee, S. K., Lim, S. C. J., Pong, P. S., & Dahlan, S. H. (2020) · Progress In Electromagnetics Research C · doi:10.2528/pierc19110501 · Cited by 29 · cited 1×
“tion, diabetics must bear the cost of tapes and the boredom to perform repeated tests [3].”
Xiao, X., Yu, Q., Li, Q., Song, H., & Kikkawa, T. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3010680 · Cited by 29 · cited 1×
“Many studies have consistently suggested promising results and various methods for measuring the EM properties of blood glucose in tissues; for example, split ring resonators [38] and complementary split ring resonators [39], antennas [40]–[42] and filters [43], transmission lines [44] and coaxial [45], implantable de…”
In vitro analysis of a microwave sensor for noninvasive glucose monitoring
Sethi, W. T., Issa, K., Ashraf, M. A., & Alshebeili, S. A. (2018) · Microwave and Optical Technology Letters · doi:10.1002/mop.31629 · Cited by 22 · cited 1×
“Lifestyle changes and a healthy diabetic diet are the only treatment, as it is not permanently curable [2].”
Tschaikner, M., Powell, K., Jungklaus, M., Fritz, M., Ellmerer, M., Hovorka, R., Lane, S., Pieber, T. R., & Regittnig, W. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2925434 · Cited by 19 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
Islam, M., Ali, M. S., Shoumy, N. J., Khatun, S., Karim, M. S. A., & Bari, B. S. (2020) · SN Applied Sciences · doi:10.1007/s42452-019-1884-3 · Cited by 18
Tschaikner, M., Simic, A., Jungklaus, M., Fritz, M., Ellmerer, M., Pieber, T. R., & Regittnig, W. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2919234 · Cited by 17 · cited 1×
“Some technologies including optical [7], transdermal techniques [8], thermal spectrum measurement [9], breath acetone analysis [10], impedance spectroscopy [11], saliva analysis [12], graphene-based nanosensors [13], electrochemical methods that measure glucose level in urine [14], sweat and interstitial fluid (ISF) […”
A 1.8-GHz Near-Field Dielectric Plethysmography Heart-Rate Sensor With Time-Based Edge Sampling
Chien, J. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2951691 · Cited by 11 · cited 1×
“Another realized technology is the continuous noninvasive measurement and control of blood glucose using electromagnetic (EM) waves due to its ability to penetrate body tissues [23].”
Cai, L., Jiang, Z. H., Huang, Y., & Hong, W. (2020) · IEEE Access · doi:10.1109/access.2020.2972039 · Cited by 10 · cited 1×
“The CPW feed section for this circuit is emanated from [53], [54], the transition sector from [49], the SIW cavity segment from [55], and the sensing location part from [56].”
Metadata
- Authors
- Kiani, S., Rezaei, P., & Fakhr, M.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2021
- Volume
- 70
- Pages
- 1-8
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W3132704342
- Cited by
- 220
- References
- 49
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.