Error Analysis and Accuracy Calibration Method of U-Tube Coriolis Mass Flowmeter Under Pulsating Flow
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Coriolis mass flowmeter (CMF) is a kind of flow measurement instrument which can directly measure the high precision transient mass flow parameters. And the vibration characteristic of the U-shaped measuring tube inside is one of the important factors that determine the measuring accuracy. The pulsating flow through the measuring tube will lead to the motion component except the main vibration frequency, which will affect the phase difference calculation and reduce the measurement accuracy of the mass flowmeter. This paper presents a method to improve the accuracy of U-tube CMF based on variable step size Least Mean Square (LMS) filter and Hilbert transform with interval-shifting under pulsating flow. Experimental work was conducted on a dynamic experimental platform of pulsating flow. Experimental results show that the stability and accuracy of the proposed algorithm are better than the traditional CMF phase difference calibration method. The mean time difference error is 9.0525μs, and the mean time difference relative error is 5.806%. The calibration effect is more than 88.0934% better than other traditional algorithms. It is verified that it has good error calibration effect for pulsating flow at various frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, T., & Baker, R. (2014) · Flow Measurement and Instrumentation · doi:10.1016/j.flowmeasinst.2014.08.015 · Cited by 199
The dynamics of a piping system with internal unsteady flow
Lee, U., Pak, C. H., & Hong, S. C. (1995) · Journal of Sound and Vibration · doi:10.1006/jsvi.1995.0080 · Cited by 83
THE EFFECT OF FLOW PULSATIONS ON CORIOLIS MASS FLOW METERS
Cheesewright, R., & Clark, C. (1998) · Journal of Fluids and Structures · doi:10.1006/jfls.1998.0176 · Cited by 56
A Mathematical Model and Error Analysis of Coriolis Mass Flowmeters
Kazahaya, M. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2086691 · Cited by 32
Experimental analysis of thermomechanical noise in micro Coriolis mass flow sensors
Alveringh, D., Wiegerink, R. J., Groenesteijn, J., Sanders, R. G. P., & Lötters, J. C. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.01.024 · Cited by 12
Fluid–Structure Interaction Simulation of a Coriolis Mass Flowmeter Using a Lattice Boltzmann Method
Haussmann, M., Reinshaus, P., Simonis, S., Nirschl, H., & Krause, M. J. (2021) · Fluids · doi:10.3390/fluids6040167 · Cited by 1
Research works printed but not linked: 25
- 10.1016/j.flowmeasinst.2019.101613 · doi:10.1016/j.flowmeasinst.2019.101613
- 10.1016/j.flowmeasinst.2006.12.006 · doi:10.1016/j.flowmeasinst.2006.12.006
- tu, 2008, Method for CMF signal processing based on the recursive DTFT algorithm with negative frequency contribution, IEEE Trans Instrum Meas, 57, 2647, 10.1109/TIM.2008.925006 · doi:10.1109/tim.2008.925006
- 10.1109/ICIT.2016.7474833 · doi:10.1109/icit.2016.7474833
- 10.1155/2020/7960546 · doi:10.1155/2020/7960546
- zhang, 2017, Applications of digital signal processing technology in Coriolis mass flowmeter, Chin J Sci Instrum, 38, 2087
- tu, 2015, Error analysis of DFT or DTFT based phase difference measurement considering the negative frequency contribution, J Vib Shock, 34, 85
- 10.1007/s12647-012-0017-x · doi:10.1007/s12647-012-0017-x
- 10.1109/JSEN.2020.3042078 · doi:10.1109/jsen.2020.3042078
- 10.1109/CISCE.2019.00070 · doi:10.1109/cisce.2019.00070
- qi, 2016, Principle and application of mass flow meter, Instrumentation, 23, 44
- 10.1016/j.flowmeasinst.2010.07.003 · DOI
- 10.1016/j.proeng.2014.11.535 · doi:10.1016/j.proeng.2014.11.535
- 10.1109/TIM.2006.877719 · doi:10.1109/tim.2006.877719
- yin, 2013, Computer aided design of Coriolis mass flow-meter based on fluid-structure coupling calculation, Mar Eng, 35, 140
- 10.1016/j.jsv.2015.05.014 · doi:10.1016/j.jsv.2015.05.014
- van, 2014, Quantification of the influence of external vibrations on the measurement error of a Coriolis mass-flow meter, Flow Meas Instrum, 40, 39, 10.1016/j.flowmeasinst.2014.08.005 · doi:10.1016/j.flowmeasinst.2014.08.005
- 10.1109/ICMTMA.2010.121 · doi:10.1109/icmtma.2010.121
- 10.1109/JSEN.2013.2260859 · doi:10.1109/jsen.2013.2260859
- binulal, 2014, Coriolis flow meter: A review from 1989 to 2014, Int J Sci Eng Res, 5, 718
- 10.1109/MEMSYS.2016.7421591 · doi:10.1109/memsys.2016.7421591
- 10.1016/j.sna.2019.06.020 · doi:10.1016/j.sna.2019.06.020
- 10.1109/I2MTC.2018.8409623 · doi:10.1109/i2mtc.2018.8409623
- ch, 2016, Calculation method of oil quantity in dynamic measurement of crude oil, Chemical Management, 32, 190
- 10.1109/ICEMI.2017.8265702 · doi:10.1109/icemi.2017.8265702
Cited by
DCdetector: Dual Attention Contrastive Representation Learning for Time Series Anomaly Detection
Yang, Y., Zhang, C., Zhou, T., Wen, Q., & Sun, L. (2023) · Proceedings of the 29th ACM SIGKDD Conference on Knowledge Discovery and Data Mining · doi:10.1145/3580305.3599295 · Cited by 387
Wang, X., Dai, K., Hu, M., & Ni, N. (2024) · Journal of Energy Storage · doi:10.1016/j.est.2024.112442 · Cited by 72
Enhancing accuracy and convenience of golf swing tracking with a wrist-worn single inertial sensor
Kim, M., & Park, S. (2024) · Scientific Reports · doi:10.1038/s41598-024-59949-w · Cited by 14
Metadata
- Authors
- Yang, H., Zhang, L., Li, L., Liang, H., & Zou, J.
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2021
- Volume
- 70
- Pages
- 1-13
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W3213777593
- Cited by
- 391
- References
- 6
- FWCI
- 32.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Funders
- National Natural Science Foundation of China (51775543)
- Joint Funds of the National Natural Science Foundation of China (U1610111)
- Sichuan Science and Technology Program (2019YFG0195)
- Scientific Research Starting Project of (2018QHZ016)
- Young Scholars Development Fund of SWPU (201799010002)
- Science and Technology Cooperation Project of the CNPC-SWPU Innovation Alliance (2020CX040000)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Error Analysis and Accuracy Calibration Method of U-Tube Coriolis Mass Flowmeter Under Pulsating Flow. https://app.cochat.ai/papers/10.1109/tim.2021.3126366
- The paper
- Yang, H., Zhang, L., Li, L., Liang, H., & Zou, J. (2021). Error Analysis and Accuracy Calibration Method of U-Tube Coriolis Mass Flowmeter Under Pulsating Flow. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2021.3126366
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.