The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Segmenting and tracking fluorescent cells in dynamic 3-D microscopy with coupled active surfaces
Abstract
Cell migrations and deformations play essential roles in biological processes, such as parasite invasion, immune response, embryonic development, and cancer. We describe a fully automatic segmentation and tracking method designed to enable quantitative analyses of cellular shape and motion from dynamic three-dimensional microscopy data. The method uses multiple active surfaces with or without edges, coupled by a penalty for overlaps, and a volume conservation constraint that improves outlining of cell/cell boundaries. Its main advantages are robustness to low signal-to-noise ratios and the ability to handle multiple cells that may touch, divide, enter, or leave the observation volume. We give quantitative validation results based on synthetic images and show two examples of applications to real biological data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Fronts propagating with curvature-dependent speed: Algorithms based on Hamilton-Jacobi formulations
Osher, S., & Sethian, J. A. (1988) · Journal of Computational Physics · doi:10.1016/0021-9991(88)90002-2 · Cited by 14,062
Scale-space and edge detection using anisotropic diffusion
Perona, P., & Malik, J. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.56205 · Cited by 12,119
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
Caselles, V., Kimmel, R., & Sapiro, G. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007979827043 · Cited by 5,244
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Level Set Methods and Fast Marching Methods
Sethian, J. A. (1999) · Medical Entomology and Zoology · Cited by 3,616
Shape modeling with front propagation: a level set approach
Malladi, R., Sethian, J. A., & Vemuri, B. C. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.368173 · Cited by 3,158
A Multiphase Level Set Framework for Image Segmentation Using the Mumford and Shah Model
Vese, L. A., & Chan, T. F. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020874308076 · Cited by 2,384
Cited by
Icy: an open bioimage informatics platform for extended reproducible research
de Chaumont, F., Dallongeville, S., Chenouard, N., Hervé, N., Pop, S., Provoost, T., Meas-Yedid, V., Pankajakshan, P., Lecomte, T., Le Montagner, Y., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2075 · Cited by 1,538
Self-citationAn objective comparison of cell-tracking algorithms
Ulman, V., Maška, M., Magnusson, K. E. G., Ronneberger, O., Haubold, C., Harder, N., Matula, P., Matula, P., Svoboda, D., Radojevic, M., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4473 · Cited by 565
Self-citationXing, F., & Yang, L. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2515127 · Cited by 519
A benchmark for comparison of cell tracking algorithms
Maška, M., Ulman, V., Svoboda, D., Matula, P., Matula, P., Ederra, C., Urbiola, A., España, T., Venkatesan, S., Balak, D. M. W., et al. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu080 · Cited by 415
An Automatic Learning-Based Framework for Robust Nucleus Segmentation
Xing, F., Xie, Y., & Yang, L. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2481436 · Cited by 351
Image processing and classification algorithm for yeast cell morphology in a microfluidic chip
Yang Yu, B., Elbuken, C., Ren, C. L., & Huissoon, J. P. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3589100 · Cited by 349
Cell population tracking and lineage construction with spatiotemporal context
Li, K., Miller, E. D., Chen, M., Kanade, T., Weiss, L. E., & Campbell, P. G. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.06.001 · Cited by 346
Segmentation of Clustered Nuclei With Shape Markers and Marking Function
Cheng, J., & Rajapakse, J. C. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008635 · Cited by 302
Automated Subcellular Location Determination and High-Throughput Microscopy
Glory, E., & Murphy, R. F. (2007) · Developmental Cell · doi:10.1016/j.devcel.2006.12.007 · Cited by 284
Visualization of image data from cells to organisms
Walter, T., Shattuck, D. W., Baldock, R., Bastin, M. E., Carpenter, A. E., Duce, S., Ellenberg, J., Fraser, A., Hamilton, N., Pieper, S., et al. (2010) · Nature Methods · doi:10.1038/nmeth.1431 · Cited by 266
Advanced Level-Set-Based Cell Tracking in Time-Lapse Fluorescence Microscopy
Dzyubachyk, O., van Cappellen, W. A., Essers, J., Niessen, W. J., & Meijering, E. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2038693 · Cited by 255
Megason, S. G., & Fraser, S. E. (2007) · Cell · doi:10.1016/j.cell.2007.08.031 · Cited by 254
Metadata
- Authors
- Dufour, A., Shinin, V., Tajbakhsh, S., Guillen-Aghion, N., Olivo-Marin, J.-C., & Zimmer, C.
- Venue
- IEEE Transactions on Image Processing
- Published
- 2005-09
- Volume
- 14
- Issue
- 9
- Pages
- 1396-1410
- ISSN
- 1057-7149 (ISSN-L)
- OpenAlex
- W2162245111
- Cited by
- 309
- References
- 42
- FWCI
- 9.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.