The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Implementation of a WAP-based telemedicine system for patient monitoring
Abstract
Many parties have already demonstrated telemedicine applications that use cellular phones and the Internet. A current trend in telecommunication is the convergence of wireless communication and computer network technologies, and the emergence of wireless application protocol (WAP) devices is an example. Since WAP will also be a common feature found in future mobile communication devices, it is worthwhile to investigate its use in telemedicine. This paper describes the implementation and experiences with a WAP-based telemedicine system for patient-monitoring that has been developed in our laboratory. It utilizes WAP devices as mobile access terminals for general inquiry and patient-monitoring services. Authorized users can browse the patients' general data, monitored blood pressure (BP), and electrocardiogram (ECG) on WAP devices in store-and-forward mode. The applications, written in wireless markup language (WML), WMLScript, and Perl, resided in a content server. A MySQL relational database system was set up to store the BP readings, ECG data, patient records, clinic and hospital information, and doctors' appointments with patients. A wireless ECG subsystem was built for recording ambulatory ECG in an indoor environment and for storing ECG data into the database. For testing, a WAP phone compliant with WAP 1.1 was used at GSM 1800 MHz by circuit-switched data (CSD) to connect to the content server through a WAP gateway, which was provided by a mobile phone service provider in Hong Kong. Data were successfully retrieved from the database and displayed on the WAP phone. The system shows how WAP can be feasible in remote patient-monitoring and patient data retrieval.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of the noise sensitivity of nine QRS detection algorithms
Friesen, G. M., Jannett, T. C., Jadallah, M. A., Yates, S. L., Quint, S. R., & Nagle, H. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.43620 · Cited by 1,043
A novel emergency telemedicine system based on wireless communication technology-AMBULANCE
Pavlopoulos, S., Kyriacou, E., Berler, A., Dembeyiotis, S., & Koutsouris, D. (1998) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.737581 · Cited by 282
Physiological Basis of Aging and Geriatrics
(2002) · CRC Press eBooks · doi:10.1201/9781420041279 · Cited by 233
An Introduction to Telemedicine
(2021) · Journal opf Pakistan Society of Internal Medicine · doi:10.70302/jpsim.v2i2.2140 · Cited by 225
Guide to medical informatics, the internet and telemedicine
(1997) · Computational Statistics & Data Analysis · doi:10.1016/s0167-9473(97)90119-5 · Cited by 184
Physiological Basis of Aging and Geriatrics
(2007) · CRC Press eBooks · doi:10.3109/9781420007091 · Cited by 128
PACS: Basic Principles and Applications
Huang, H. K. (1999) · Radiology · doi:10.1148/radiology.212.1.r99jl54202 · Cited by 94
Applying telecommunication technology to health-care delivery
Lin, J. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.775486 · Cited by 93
Transmission of electrocardiograms from a moving ambulance
Giovas, P. P., Papadoyannis, D., Thomakos, D., Papazachos, G., Rallidis, M., Soulis, D., Stamatopoulos, C., Mavrogeni, S. I., & Katsilambros, N. L. (1998) · Journal of Telemedicine and Telecare · doi:10.1258/1357633981931533 · Cited by 88
Sharing health-care records over the Internet
Grimson, J. B., Stephens, G., Jung, B., Grimson, W., Berry, D., & Pardon, S. (2001) · IEEE Internet Computing · doi:10.1109/4236.935177 · Cited by 86
Reponen, J., Ilkko, E., Jyrkinen, L., Tervonen, O. A., Niinimäki, J. L., Karhula, V., & KOIVULA, A. (2000) · Journal of Telemedicine and Telecare · doi:10.1258/1357633001933943 · Cited by 83
A twenty-four hour tele-nursing system using a ring sensor
Yang, B.-H., Rhee, S., & Asada, H. H. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1998.676438 · Cited by 63
Pettis, K. S., Savona, M. R., Leibrandt, P. N., Maynard, C. C., Lawson, W. T., Gates, K. B., & Wagner, G. S. (1999) · American Heart Journal · doi:10.1016/s0002-8703(99)70194-8 · Cited by 43
Mobile computing in healthcare.
Finch, C. (1999) · PubMed · Cited by 22
Urban teleradiology in Hong Kong
Sheng, O. R. L., Hu, P. J., Au, G., Higa, K., & Wei, C. (1997) · Journal of Telemedicine and Telecare · doi:10.1258/1357633971930896 · Cited by 21
On the feasibility of the usage of WAP devices in telemedicine
Hung, K., & Zhang, Y. (2002) · doi:10.1109/itab.2000.892343 · Cited by 13
Self-citation
Cited by
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766
Self-citationPervasive Healthcare and Wireless Health Monitoring
Varshney, U. (2007) · Mobile Networks and Applications · doi:10.1007/s11036-007-0017-1 · Cited by 685
What Is Telemedicine? A Collection of 104 Peer-Reviewed Perspectives and Theoretical Underpinnings
Sood, S., Mbarika, V., Jugoo, S., Dookhy, R., Doarn, C. R., Prakash, N., & Merrell, R. C. (2007) · Telemedicine and e-Health · doi:10.1089/tmj.2006.0073 · Cited by 627
ECG signal denoising and baseline wander correction based on the empirical mode decomposition
Blanco-Velasco, M., Weng, B., & Barner, K. E. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.06.003 · Cited by 649
A novel biometrics method to secure wireless body area sensor networks for telemedicine and m-health
Poon, C. C. Y., Zhang, Y.-T., & Bao, S.-D. (2006) · IEEE Communications Magazine · doi:10.1109/mcom.2006.1632652 · Cited by 570
Self-citation
Metadata
- Authors
- Hung, K., & Zhang, Y.-T.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2003-06
- Volume
- 7
- Issue
- 2
- Pages
- 101-107
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2122806052
- Cited by
- 290
- References
- 16
- FWCI
- 19.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.