The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Self-Powered Wearable Electrocardiography Using a Wearable Thermoelectric Power Generator
Abstract
A self-powered wearable electrocardiography (ECG) system is demonstrated. The ECG sensing circuit was fabricated on a flexible PCB and powered by a wearable thermoelectric generator (w-TEG) using body heat as the energy source. To allow the TEG to obtain a large temperature difference for high power generation and also be wearable, a polymer-based flexible heat sink (PHS) comprised of a superabsorbent polymer (SAP) and a fiber that promotes liquid evaporation was devised. Parametric studies on the PHS were conducted, and the structure of the w-TEG was also optimized for the PHS. The output power density from the w-TEG with the PHS was over 38 μW/cm 2 for the first 10 min and over 13 μW/cm 2 even after 22 consecutive hours of driving the circuits. This power level is high enough to continuously drive the wearable ECG system, including the sensors and the power management circuits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in triboelectric nanogenerators as a new energy technology and self-powered sensors
Wang, Z. L., Chen, J., & Lin, L. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01532d · Cited by 2,174
Highly efficient and bending durable perovskite solar cells: toward a wearable power source
Kim, B. J., Kim, D. H., Lee, Y.-Y., Shin, H.-W., Han, G. S., Hong, J. S., Mahmood, K., Ahn, T. K., Joo, Y.-C., Hong, K. S., et al. (2015) · Energy & Environmental Science · doi:10.1039/c4ee02441a · Cited by 679
A wireless wearable ECG sensor for long-term applications
Nemati, E., Deen, M., & Mondal, T. (2012) · IEEE Communications Magazine · doi:10.1109/mcom.2012.6122530 · Cited by 418
Oh, J. Y., Lee, J. H., Han, S. W., Chae, S. S., Bae, E. J., Kang, Y. H., Choi, W. J., Cho, S. Y., Lee, J.-O., Baik, H. K., et al. (2016) · Energy & Environmental Science · doi:10.1039/c5ee03813h · Cited by 289
Self-citationHigh-Performance Flexible Thermoelectric Power Generator Using Laser Multiscanning Lift-Off Process
Kim, S. J., Lee, H. E., Choi, H., Kim, Y., We, J. H., Shin, J. S., Lee, K. J., & Cho, B. J. (2016) · ACS Nano · doi:10.1021/acsnano.6b05004 · Cited by 257
Self-citation
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931
Organic Photodetectors for Next‐Generation Wearable Electronics
Chow, P. C. Y., & Someya, T. (2020) · Advanced Materials · doi:10.1002/adma.201902045 · Cited by 779
Shi, Q., Dong, B., He, T., Sun, Z., Zhu, J., Zhang, Z., & Lee, C. (2020) · InfoMat · doi:10.1002/inf2.12122 · Cited by 661
Metadata
- Authors
- Kim, C. S., Yang, H. M., Lee, J., Lee, G. S., Choi, H., Kim, Y. J., Lim, S. H., Cho, S. H., & Cho, B. J.
- Venue
- ACS Energy Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-01-27
- Volume
- 3
- Issue
- 3
- Pages
- 501-507
- ISSN
- 2380-8195 (ISSN-L)
- OpenAlex
- W2784906225
- Cited by
- 314
- References
- 5
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-Powered Wearable Electrocardiography Using a Wearable Thermoelectric Power Generator. https://app.cochat.ai/papers/10.1021/acsenergylett.7b01237
- The paper
- Kim, C. S., Yang, H. M., Lee, J., Lee, G. S., Choi, H., Kim, Y. J., Lim, S. H., Cho, S. H., & Cho, B. J. (2018). Self-Powered Wearable Electrocardiography Using a Wearable Thermoelectric Power Generator. ACS Energy Letters. https://doi.org/10.1021/acsenergylett.7b01237
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.