Universal Glucose Models for Predicting Subcutaneous Glucose Concentration in Humans
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper tests the hypothesis that a "universal," data-driven model can be developed based on glucose data from one diabetic subject, and subsequently applied to predict subcutaneous glucose concentrations of other subjects, even of those with different types of diabetes. We employed three separate studies, each utilizing a different continuous glucose monitoring (CGM) device, to verify the model's universality. Two out of the three studies involved subjects with type 1 diabetes and the other one with type 2 diabetes. We first filtered the subcutaneous glucose concentration data by imposing constraints on their rate of change. Then, using the filtered data, we developed data-driven autoregressive models of order 30, and used them to make short-term, 30-min-ahead glucose-concentration predictions. We used same-subject model predictions as a reference for comparisons against cross-subject and cross-study model predictions, which were evaluated using the root-mean-squared error (RMSE) and Clarke error grid analysis (EGA). We found that, for each studied subject, the average cross-subject and cross-study RMSEs of the predictions were small and indistinguishable from those obtained with the same-subject models. These observations were corroborated by EGA, where better than 99.0% of the paired sensor-predicted glucose concentrations lay in the clinically acceptable zone A. In addition, the predictive capability of the models was found not to be affected by diabetes type, subject age, CGM device, and interindividual differences. We conclude that it is feasible to develop universal glucose models that allow for clinical use of predictive algorithms and CGM devices for proactive therapy of diabetic patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2002) · Springer Series in Statistics · doi:10.1007/b98835 · Cited by 919
Pulsatile Insulin Secretion: Detection, Regulation, and Role in Diabetes
Pørksen, N., Hollingdal, M., Juhl, C., Butler, P., Veldhuis, J. D., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s245 · Cited by 223 · cited 1×
“In diabetic patients, insulin-generating cells responsible for pulsatile secretion of insulin, and the corresponding 5- to 15-min periods, are severely handicapped, essentially eliminating these periods in the glucose signals [9], [ 20 ].”
Background
Cited by
Kakria, P., Tripathi, N. K., & Kitipawang, P. (2015) · International Journal of Telemedicine and Applications · doi:10.1155/2015/373474 · Cited by 410
“According to existing medical surveys, telemedicine has been adopted to take care of the patients with cardiac diseases, diabetes, hypotension, hypertension, hyperthermia, and hypothermia [4–8].”
BackgroundA review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279
Zecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816654161 · Cited by 64
Facchinetti, A., Favero, S., Sparacino, G., & Cobelli, C. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2227256 · Cited by 62
Metadata
- Authors
- Gani, A., Gribok, A. V., Lu, Y., Ward, W. K., Vigersky, R. A., & Reifman, J.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2010-01
- Volume
- 14
- Issue
- 1
- Pages
- 157-165
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2158711921
- Cited by
- 124
- References
- 2
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.