Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A ballistocardiograph records the mechanical activity of the heart. We present a novel algorithm for the detection of individual heart beats and beat-to-beat interval lengths in ballistocardiograms (BCGs) from healthy subjects. An automatic training step based on unsupervised learning techniques is used to extract the shape of a single heart beat from the BCG. Using the learned parameters, the occurrence of individual heart beats in the signal is detected. A final refinement step improves the accuracy of the estimated beat-to-beat interval lengths. Compared to many existing algorithms, the new approach offers heart rate estimates on a beat-to-beat basis. The agreement of the proposed algorithm with an ECG reference has been evaluated. A relative beat-to-beat interval error of 1.79% with a coverage of 95.94% was achieved on recordings from 16 subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“In the recorded ECGs, the locations of the R peaks were detected using the Pan–Tompkins algorithm [ 36 ].”
MethodChee, Y., Han, J., Youn, J., & Park, K. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/007 · Cited by 111
Cited by
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“This method has been recently implemented using inexpensive and convenient instrumentation such as chairs [102], beds [103], weighing scales [104], and onbody accelerometers [105].”
MethodBallistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
“in 2011 with low error [51].”
BackgroundBallistocardiogram signal processing: a review
Sadek, I., Biswas, J., & Abdulrazak, B. (2019) · Health Information Science and Systems · doi:10.1007/s13755-019-0071-7 · Cited by 216
Ambient and Unobtrusive Cardiorespiratory Monitoring Techniques
Bruser, C., Antink, C. H., Wartzek, T., Walter, M., & Leonhardt, S. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2414661 · Cited by 175
“position and orientation of the subject toward the sensor [16].”
BackgroundSelf-citationSimultaneous monitoring of ballistocardiogram and photoplethysmogram using a camera
Shao, D., Tsow, F., Liu, C., Yang, Y., & Tao, N. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2585109 · Cited by 69
Metadata
- Authors
- Bruser, C., Stadlthanner, K., de Waele, S., & Leonhardt, S.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2011-09
- Volume
- 15
- Issue
- 5
- Pages
- 778-786
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2168752508
- Cited by
- 219
- References
- 2
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.