Developing a Wireless Implantable Body Sensor Network in MICS Band
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Through an integration of wireless communication and sensing technologies, the concept of a body sensor network (BSN) was initially proposed in the early decade with the aim to provide an essential technology for wearable, ambulatory, and pervasive health monitoring for elderly people and chronic patients. It has become a hot research area due to big opportunities as well as great challenges it presents. Though the idea of an implantable BSN was proposed in parallel with the on-body sensor network, the development in this area is relatively slow due to the complexity of human body, safety concerns, and some technological bottlenecks such as the design of ultralow-power implantable RF transceiver. This paper describes a new wireless implantable BSN that operates in medical implant communication service (MICS) frequency band. This system innovatively incorporates both sensing and actuation nodes to form a closed-control loop for physiological monitoring and drug delivery for critically ill patients. The sensing node, which is designed using system-on-chip technologies, takes advantage of the newly available ultralow-power Zarlink MICS transceiver for wireless data transmission. Finally, the specific absorption rate distribution of the proposed system was simulated to determine the in vivo electromagnetic field absorption and the power safety limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
A wireless single-chip telemetry-powered neural stimulation system
Von Arx, J. A., & Najafi, K. (2003) · 1999 IEEE International Solid-State Circuits Conference. Digest of Technical Papers. ISSCC. First Edition (Cat. No.99CH36278) · doi:10.1109/isscc.1999.759199 · Cited by 74 · cited 1×
“In recent years, electromagnetic propagation through inductive coupling links has been commonly used to deliver power and information for implanted systems [ 19 ], [20].”
Background
Cited by
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Development of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
“Therefore, the US Federal Communications Commission and European Telecommunications Standards Institute have defined the Medical Implants Communication Services band (402–405 MHz) as the implantable medical device frequency range [83,84].”
BackgroundShon, A., Chu, J.-U., Jung, J., Kim, H., & Youn, I. (2017) · Sensors · doi:10.3390/s18010001 · Cited by 320
Protection of data confidentiality and patient privacy in medical sensor networks
Sankar, R., Le, X. H., Lee, S., & Wang, D. (2013) · Implantable Sensor Systems for Medical Applications · doi:10.1533/9780857096289.2.279 · Cited by 7
Self-citation
Metadata
- Authors
- Fang, Q., Lee, S.-Y., Permana, H., Ghorbani, K., & Cosic, I.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2011-07
- Volume
- 15
- Issue
- 4
- Pages
- 567-576
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2117239299
- Cited by
- 51
- References
- 2
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.