The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode
Open accessAbstract
Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Planar Wireless Charging Technology for Portable Electronic Products and Qi
Hui, S. Y. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2246531 · Cited by 648
Saper, J. R., Dodick, D. W., Silberstein, S. D., McCarville, S., Sun, M., & Goadsby, P. J. (2011) · Cephalalgia · doi:10.1177/0333102410381142 · Cited by 425
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications
Yin, M., Borton, D. A., Aceros, J., Patterson, W. R., & Nurmikko, A. V. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2255874 · Cited by 165
MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control
Kyberd, P., Holland, O. E., Chappell, P. H., Smith, S., Tregidgo, R., Bagwell, P. J., & Snaith, M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.372895 · Cited by 121
An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up
Guiraud, D., Stieglitz, T., Koch, K. P., Divoux, J., & Rabischong, P. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/003 · Cited by 120
A fully implantable 96-channel neural data acquisition system
Rizk, M., Bossetti, C. A., Jochum, T. A., Callender, S. H., Nicolelis, M. A. L., Turner, D. A., & Wolf, P. D. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026002 · Cited by 95
Enabling Wireless Powering and Telemetry for Peripheral Nerve Implants
Jegadeesan, R., Nag, S., Agarwal, K., Thakor, N. V., & Guo, Y. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2424985 · Cited by 94
Cited by
A survey of deep learning techniques for autonomous driving
Grigorescu, S., Trasnea, B., Cocias, T., & Macesanu, G. (2020) · Journal of Field Robotics · doi:10.1002/rob.21918 · Cited by 1,809
A systematic review of convolutional neural network-based structural condition assessment techniques
Sony, S., Dunphy, K., Sadhu, A., & Capretz, M. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2020.111347 · Cited by 398
A survey on methods and challenges in EEG based authentication
Jalaly Bidgoly, A., Jalaly Bidgoly, H., & Arezoumand, Z. (2020) · Computers & Security · doi:10.1016/j.cose.2020.101788 · Cited by 173
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“By integrating stimulation and recording electrodes in a single PNI, however, a major concern is associated with the generation of stimulation artifacts, which can lead to loss of recording information and requires specific signal processing or additional circuitry to be rejected [197].”
BackgroundRecent progress on peripheral neural interface technology towards bioelectronic medicine
Cho, Y., Park, J., Lee, C., & Lee, S. (2020) · Bioelectronic Medicine · doi:10.1186/s42234-020-00059-z · Cited by 55
Metadata
- Authors
- Shon, A., Chu, J.-U., Jung, J., Kim, H., & Youn, I.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2017-12-21
- Volume
- 18
- Issue
- 1
- Pages
- 1
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2779589467
- Cited by
- 320
- References
- 43
- FWCI
- 20.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode. https://app.cochat.ai/papers/10.3390/s18010001
- The paper
- Shon, A., Chu, J.-U., Jung, J., Kim, H., & Youn, I. (2017). An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode. Sensors. https://doi.org/10.3390/s18010001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.