Assessment of Tremor Activity in the Parkinson’s Disease Using a Set of Wearable Sensors
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Tremor is the most common motor disorder of Parkinson's disease (PD) and consequently its detection plays a crucial role in the management and treatment of PD patients. The current diagnosis procedure is based on subject-dependent clinical assessment, which has a difficulty in capturing subtle tremor features. In this paper, an automated method for both resting and action/postural tremor assessment is proposed using a set of accelerometers mounted on different patient's body segments. The estimation of tremor type (resting/action postural) and severity is based on features extracted from the acquired signals and hidden Markov models. The method is evaluated using data collected from 23 subjects (18 PD patients and 5 control subjects). The obtained results verified that the proposed method successfully: 1) quantifies tremor severity with 87 % accuracy, 2) discriminates resting from postural tremor, and 3) discriminates tremor from other Parkinsonian motor symptoms during daily activities.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Related works on the characteristics of tremor have been reported, in which amplitude and frequency parameters were proved to be significantly different between the PD patients and healthy controls [33].”
From Detection and Quantification of Resting Tremor in Parkinson's Disease Using Long-Term Acceleration Data (2021) · cites this paper as [33]
In the citing paper
“87% for tremors [3]”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
In the citing paper
“This system, called PERFORM, is based on a Body Area Network (BAN) of sensors which has already been validated both from the technical and clinical point for view.”
From Wearability Assessment of a Wearable System for Parkinson’s Disease Remote Monitoring Based on a Body Area Network of Sensors (2014) · cites this paper as [3]
Citations
Cites
A tutorial on hidden Markov models and selected applications in speech recognition
Rabiner, L. R. (1989) · Proceedings of the IEEE · doi:10.1109/5.18626 · Cited by 22,743
Artificial intelligence: A modern approach
Nilsson, N. J. (1996) · Artificial Intelligence · doi:10.1016/0004-3702(96)00007-0 · Cited by 10,583
Wrappers for feature subset selection
Kohavi, R., & John, G. H. (1997) · Artificial Intelligence · doi:10.1016/s0004-3702(97)00043-x · Cited by 8,947
Parkinson's disease: clinical features and diagnosis
Jankovic, J. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.131045 · Cited by 5,720 · cited 4×
“ered a difficult task even by experts [2], [11].”
InfluentialAn introduction to hidden Markov models
Rabiner, L., & Juang, B. (1986) · IEEE ASSP Magazine · doi:10.1109/massp.1986.1165342 · Cited by 4,775
The bayes net toolbox for matlab
Murphy, K. (2001) · Cited by 1,014
Monitoring Motor Fluctuations in Patients With Parkinson's Disease Using Wearable Sensors
Patel, S., Lorincz, K., Hughes, R., Huggins, N., Growdon, J., Standaert, D., Akay, M., Dy, J., Welsh, M., & Bonato, P. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033471 · Cited by 623
Detection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480
Assessment of physical activity: a critical appraisal
Westerterp, K. R. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1000-2 · Cited by 459
Activity Recognition of Assembly Tasks Using Body-Worn Microphones and Accelerometers
Ward, J. A., Lukowicz, P., Troster, G., & Starner, T. E. (2006) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2006.197 · Cited by 431
Salarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
Classifying household and locomotive activities using a triaxial accelerometer
Oshima, Y., Kawaguchi, K., Tanaka, S., Ohkawara, K., Hikihara, Y., Ishikawa-Takata, K., & Tabata, I. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.01.005 · Cited by 371
Capturing human motion using body‐fixed sensors: outdoor measurement and clinical applications
Aminian, K., & Najafi, B. (2004) · Computer Animation and Virtual Worlds · doi:10.1002/cav.2 · Cited by 280
Post, B., Merkus, M. P., de Bie, R. M. A., de Haan, R. J., & Speelman, J. D. (2005) · Movement Disorders · doi:10.1002/mds.20640 · Cited by 266
Clinical Neurophysiology of Tremor
Deuschl, G., Krack, P., Lauk, M., & Timmer, J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00002 · Cited by 210
Time-frequency analysis of tremors
O'Suilleabhain, P. (1998) · Brain · doi:10.1093/brain/121.11.2127 · Cited by 157
Ambulatory Monitoring of Activities and Motor Symptoms in Parkinson's Disease
Zwartjes, D. G. M., Heida, T., van Vugt, J. P. P., Geelen, J. A. G., & Veltink, P. H. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2049573 · Cited by 128
Characteristics of hand tremor time series
Timmer, J., Gantert, C., Deuschl, G., & Honerkamp, J. (1993) · Biological Cybernetics · doi:10.1007/bf00202568 · Cited by 112
Findley, L. J. (1996) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199603000-00003 · Cited by 104
A new actigraph for long-term registration of the duration and intensity of tremor and movement
Van Someren, E. J. W., Vonk, B. F. M., Thijssen, W. A., Speelman, J. D., Schuurman, P. R., Mirmiran, M., & Swaab, D. F. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661163 · Cited by 91
Norman, K. E., Edwards, R., & Beuter, A. C. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00091-6 · Cited by 88
Adaptive Fourier modeling for quantification of tremor
Riviere, C. N., Reich, S. G., & Thakor, N. V. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02263-2 · Cited by 83 · cited 3×
“by computational methods such as time-domain analysis [12], spectral analysis [13], time-frequency analysis [14], and nonlinear analysis [13].”
BackgroundMethodRapid tremor frequency assessment with the iPhone accelerometer
Joundi, R. A., Brittain, J.-S., Jenkinson, N., Green, A. L., & Aziz, T. (2011) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2011.01.001 · Cited by 69
Ambulatory Objective Assessment of Tremor in Parkinson's Disease
Hoff, J. I., Wagemans, E. A., & van Hilten, B. J. (2001) · Clinical Neuropharmacology · doi:10.1097/00002826-200109000-00004 · Cited by 65
24 Hour continuous tremor quantification based on EMG recording
Bacher, M., Scholz, E., & Diener, H. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90179-x · Cited by 60
A novel quantitative method for 3D measurement of Parkinsonian tremor
Rajaraman, V., Jack, D., Adamovich, S. V., Hening, W., Sage, J., & Howard Poizner, A. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00230-8 · Cited by 57
Kinetic tremor in a reach-to-grasp movement in Parkinson's disease
Wenzelburger, R., Raethjen, J., L�ffler, K., Stolze, H., Illert, M., & Deuschl, G. (2000) · Movement Disorders · doi:10.1002/1531-8257(200011)15:6<1084::aid-mds1005>3.0.co;2-y · Cited by 57
Validation for tremor quantification of an electromagnetic tracking device
O'Suilleabhain, P. E., & Dewey, R. B. (2001) · Movement Disorders · doi:10.1002/mds.1064 · Cited by 53 · cited 1×
“[25]–[28], gyroscopes [17], [25], electromyography (EMG) [1], handwriting and drawing samples [13], [20], actigraphy [21], electromagnetic tracking [22], [23], and a laser system for trans-”
BackgroundParkinson's disease tremor is diminished with relaxation guided imagery
Schlesinger, I., Benyakov, O., Erikh, I., Suraiya, S., & Schiller, Y. (2009) · Movement Disorders · doi:10.1002/mds.22671 · Cited by 50
Development of a System for Measurement and Analysis of Tremor Using a Three-axis Accelerometer
Iizuka, T., Takeuchi, A., Shirataka, M., Ikeda, N., & Mamorita, N. (2009) · Methods of Information in Medicine · doi:10.3414/me9243 · Cited by 49
Quantitative tremor measurement with the computerized analysis of spiral drawing.
Rudzińska, M., Izworski, A., Banaszkiewicz, K., Bukowczan, S., Marona, M., & Szczudlik, A. (2007) · PubMed · Cited by 33
Assessment of rest tremor in Parkinson's disease.
Budzianowska, A., & Honczarenko, K. (2008) · PubMed · Cited by 31
24-h Assessment of Tremor Activity and Posture in Parkinson's Disease by Multi-Channel Accelerometry
Smeja, M., Foerster, F., Fuchs, G., Emmans, D., Hornig, A., & Fahrenberg, J. (1999) · Journal of Psychophysiology · doi:10.1027//0269-8803.13.4.245 · Cited by 30
Patel, S., Hughes, R. L., Huggins, N., Standaert, D. G., Growdon, J. H., Dy, J., & Bonato, P. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650009 · Cited by 26
Research works printed but not linked: 1
- zwartjes, 2010, Development of a system for measurement and analysis of tremor using a three-axis accelerometer, IEEE Trans Biomed Eng, 57, 2779
Cited by
Collection and Analysis of a Parkinson Speech Dataset With Multiple Types of Sound Recordings
Sakar, B. E., Isenkul, M. E., Sakar, C. O., Sertbas, A., Gurgen, F., Delil, S., Apaydin, H., & Kursun, O. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2245674 · Cited by 703
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Implantable devices: issues and challenges
Bazaka, K., & Jacob, M. (2012) · Electronics · doi:10.3390/electronics2010001 · Cited by 358
“network was able to accurately quantify the severity of the tremors with 87% accuracy, separating resting and postural tremors, and discriminating tremors from other Parkinsonian motor symptoms during daily activities [115].”
Kubota, K. J., Chen, J. A., & Little, M. A. (2016) · Movement Disorders · doi:10.1002/mds.26693 · Cited by 210
Ali, L., Zhu, C., Zhang, Z., & Liu, Y. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2940900 · Cited by 199
Metadata
- Authors
- Rigas, G., Tzallas, A. T., Tsipouras, M. G., Bougia, P., Tripoliti, E. E., Baga, D., Fotiadis, D. I., Tsouli, S. G., & Konitsiotis, S.
- Affiliations
- University of Ioannina (GR)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2012-05
- Volume
- 16
- Issue
- 3
- Pages
- 478-487
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2159209410
- Cited by
- 241
- References
- 34
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 17 · 2023: 19 · 2022: 22 · 2021: 27 · 2020: 18 · 2019: 35 · 2018: 17 · 2017: 12 · 2016: 19 · 2015: 9 · 2014: 15 · 2013: 11 · 2012: 2
- FWCI
- 12.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Health Sciences › Medicine › Clinical Neurology › Parkinson's Disease Mechanisms and Treatments
- Keywords
- Parkinson's disease, tremor assessment, wearable sensors, accelerometer, resting tremor, postural tremor, hidden Markov models, parkinsonian motor symptoms
- MeSH terms
- Aged, Algorithms, Clothing, Humans, Markov Chains, Middle Aged, Movement, Parkinson Disease, Posture, Tremor, Case-Control Studies, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.