A differential magnetometer, a molypermalloy magnetic shield, and a digital data acquisition system have been developed for detailed analysis of the human vector magnetocardiogram (VMCG). With this system, the VMCG can be recorded at any desired point around the subject's thorax while simultaneously recording the vector electrocardiogram (VECG). To simplify analysis of the three-dimensional time dependent vector magnetic field, the spatial variation of the VMCG can be described in terms of the field produced by an effective source such as a magnetic multipole series. We find the VMCG field from normal subjects to be sufficiently dipolar that a magnetic dipole alone can be used to describe the major features of the VMCG. A partial inversion of the dipole field equations and numerical analysis techniques are used to determine the components and location of the dipole that provides the least-squares fit of the dipole fields to the observed ones.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“An alternative approach to single-channel mapping came from Stanford, where the three orthogonal components of cardiac MF (so-called vector magnetocardiography) were measured at a single position over the heart, based on the theoretical assumption that like in vector electrocardiography, the three-dimensional (3D) motion of the magnetic heart vector represents the overall activity of the heart (2,”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [36]
Citations
Cites
Hospers, J. (1968) · Tectonophysics · doi:10.1016/0040-1951(68)90038-3 · Cited by 568
Zimmerman, J. E., & Frederick, N. V. (1971) · Applied Physics Letters · doi:10.1063/1.1653725 · Cited by 152
The magnetocardiogram in cardiac disorders
SAARINEN, M., KARP, P. J., KATILA, T. E., & SILTANEN, P. (1974) · Cardiovascular Research · doi:10.1093/cvr/8.6.820 · Cited by 61
Superconducting instrument systems
Goodman, W. L., Hesterman, V. W., Rorden, L. H., & Goree, J. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.8965 · Cited by 51 · cited 1×
“Fig. 5. Components ( 2 ) and location (xyz) of the best fit magnetic dipole calculated from 6 field measurements.”
BackgroundA superconducting second-derivative gradiometer
Opfer, J. E., Yeo, Y., Pierce, J. M., & Rorden, L. H. (1974) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1974.1058425 · Cited by 45 · cited 2×
“A simultaneous VECG electric dipole ( 3 ) and the instantaneous angle between 6 and and the ratio of their magnitudes are given.”
BackgroundA Study of the Vector Magnetocardiographic Waveform
Rosen, A., & Inouye, G. T. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324556 · Cited by 20
Wikswo, J. P., Opfer, J. E., & Fairbank, W. M. (1974) · doi:10.1063/1.2947281 · Cited by 7
Self-citation
Research works printed but not linked: 3
- malmivuo, 1976, On the Detection of the Magnet: Heart Vector--An Application of the Reciprocity Theorem Acta Polytechnica Scandinavica, Electrical Engineering
- wikswo, 1975, Vector Magnetocardiography--An Improved Technique for Observation of the Electrical Activity of the Human Heart, Proceedings of the San Diego Biomedical Symposium, 14, 359
- wikswo, 1975, Non-invasive magnetic measurement of the electrical and mechanical activity of the heart
Cited by
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Measurement of the human magnetic heart vector.
Barry, W. H., Fairbank, W., Harrison, D., Lehrman, K. L., Malmivuo, J., & Wikswo, J. (1977) · Science · doi:10.1126/science.929192 · Cited by 41
Self-citationMagnetic fields produced by models of biological current sources
Cuffin, B. N., & Cohen, D. (1977) · Journal of Applied Physics · doi:10.1063/1.324230 · Cited by 30
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Metadata
- Authors
- Wikswo, J., & Fairbank, W.
- Affiliations
- Stanford University (US)
- ORCID
- Wikswo, J.
- Venue
- IEEE Transactions on Magnetics
- Published
- 1977-01
- Volume
- 13
- Issue
- 1
- Pages
- 354-357
- ISSN
- 0018-9464 (ISSN-L)
- OpenAlex
- W2121588089
- Cited by
- 22
- References
- 7
- Citations by year
- 2024: 2 · 2023: 1 · 2022: 1 · 2019: 1 · 2015: 1 · 2014: 3
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- superconducting magnetometer, magnetic dipole source, dipole inversion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of superconducting magnetometers to the measurement of the vector magnetocardiogram. https://app.cochat.ai/papers/10.1109/tmag.1977.1059333
- The paper
- Wikswo, J., & Fairbank, W. (1977). Application of superconducting magnetometers to the measurement of the vector magnetocardiogram. IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.1977.1059333
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.