The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Miniature Ultrasensitive Superconducting Magnetic Gradiometer and Its Use in Cardiography and Other Applications
Abstract
A portable magnetic gradiometer was built using an rf-biased point contact device as a sensor and a superconducting flux transformer 2.5 cm in diameter by 10 cm long to couple to the gradient of the external field. The instrument is limited by fluctuations which are probably associated with an uneven boiling of the cryogenic liquids and by environmental fluctuations in some locations. It is shown that the inherent sensitivity can be increased by an order of magnitude by increasing the bias frequency from 30 to 300 MHz. A possible use of the instrument as a magnetocardiograph in an unshielded environment was demonstrated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the first technological alternative was the invention of superconducting pick-up coils designed as second- or higher-order gradiometers that would primarily measure the MF gradient closest to the source ignoring magnetic fields from further away (e.g., the environmental noise) (23).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [23]
Citations
Cites
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Self-citationQuantum States and Transitions in Weakly Connected Superconducting Rings
Silver, A. H., & Zimmerman, J. E. (1967) · Physical Review · doi:10.1103/physrev.157.317 · Cited by 309
Digital-Analog Magnetometer Utilizing Superconducting Sensor
Forgacs, R. L., & Warnick, A. (1967) · Review of Scientific Instruments · doi:10.1063/1.1771358 · Cited by 125
Recent Developments in Superconducting Devices
Zimmerman, J. E. (1971) · Journal of Applied Physics · doi:10.1063/1.1659587 · Cited by 49
Cited by
High-transition-temperature superconducting quantum interference devices
Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., & Clarke, J. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.631 · Cited by 396
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Advanced superconducting gradiometer/Magnetometer arrays and a novel signal processing technique
Wynn, W., Frahm, C., Carroll, P., Clark, R., Wellhoner, J., & Wynn, M. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058672 · Cited by 205
Magnetomyography: magnetic fields around the human body produced by skeletal muscles
Cohen, D., & Givler, E. (1972) · Applied Physics Letters · doi:10.1063/1.1654294 · Cited by 109
Metadata
- Authors
- Zimmerman, J. E., & Frederick, N. V.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1971-07-01
- Volume
- 19
- Issue
- 1
- Pages
- 16-19
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1998344359
- Cited by
- 152
- References
- 5
- Citations by year
- 2026: 2 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 2 · 2019: 5 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 1
- FWCI
- 16.47
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting Materials and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, portable instrumentation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Miniature Ultrasensitive Superconducting Magnetic Gradiometer and Its Use in Cardiography and Other Applications. https://app.cochat.ai/papers/10.1063/1.1653725
- The paper
- Zimmerman, J. E., & Frederick, N. V. (1971). Miniature Ultrasensitive Superconducting Magnetic Gradiometer and Its Use in Cardiography and Other Applications. Applied Physics Letters. https://doi.org/10.1063/1.1653725
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.