Highly Stable Amine Functionalized Iron Oxide Nanoparticles Designed for Magnetic Particle Imaging (MPI)
Open accessThe DOI matches its Crossref record.
Abstract
Magnetic particle imaging (MPI) is a promising medical imaging technology that uses iron oxide nanoparticles (NPs) as clinically safe tracers. The core and hydrodynamic size of these NPs determine the signal intensity and spatial resolution in MPI, whilst their monodispersity when preserved during the biomedical applications, generates a consistently high quality MPI image. Using an effective process to coat the synthesized NPs with amine terminated PEG molecules, we show by dynamic light scattering (DLS) that they are water-soluble with long-term stability in biological media such as phosphate buffered saline (PBS) and sodium bicarbonate buffers and Dulbecco's modified Eagle medium (DMEM) enriched with 10% fetal bovine serum (FBS). Further, using magnetic particle spectroscopy (MPS), to measure the particle response function (PRF), defined as the derivative of the magnetization of the nanoparticles, we predict the MPI performance of these nanoparticles at a driving field frequency of 25 kHz. The MPS efficacy of the functionalized nanoparticles was also monitored over time, and both signal intensity and resolution remained unchanged even after seven days of incubation. This is attributed to the dominant contribution of the Néel relaxation mechanism of the monodisperse and highly stable nanoparticles, which was preserved through the incubation period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Self-citationV.R., A. P., & A., R. (2016) · Applied Surface Science · doi:10.1016/j.apsusc.2016.04.185 · Cited by 374
Synthesis of phase-pure and monodisperse iron oxide nanoparticles by thermal decomposition
Hufschmid, R., Arami, H., Ferguson, R. M., Gonzales, M., Teeman, E., Brush, L. N., Browning, N. D., & Krishnan, K. M. (2015) · Nanoscale · doi:10.1039/c5nr01651g · Cited by 341
Self-citationMagnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“49,98 Until now, most of these scenarios still need to be assessed in vivo.”
BackgroundEnhanced Nanoparticle Size Control by Extending LaMer’s Mechanism
Vreeland, E. C., Watt, J., Schober, G. B., Hance, B. G., Austin, M. J., Price, A. D., Fellows, B. D., Monson, T. C., Hudak, N. S., Maldonado-Camargo, L., et al. (2015) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b02510 · Cited by 274
Metadata
- Authors
- Arami, H., & Krishnan, K. M.
- Venue
- IEEE Transactions on Magnetics
- Published
- 2013-07
- Volume
- 49
- Issue
- 7
- Pages
- 3500-3503
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2022984381
- Cited by
- 34
- References
- 0
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Stable Amine Functionalized Iron Oxide Nanoparticles Designed for Magnetic Particle Imaging (MPI). https://app.cochat.ai/papers/10.1109/tmag.2013.2245110
- The paper
- Arami, H., & Krishnan, K. M. (2013). Highly Stable Amine Functionalized Iron Oxide Nanoparticles Designed for Magnetic Particle Imaging (MPI). IEEE Transactions on Magnetics. https://doi.org/10.1109/tmag.2013.2245110
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.