The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.
Demagnetization Fault Indexes in Permanent Magnet Synchronous Motors—An Overview
Abstract
Demagnetization fault is the most widespread fault in permanent magnet synchronous motors (PMSMs). Diagnosing this fault and extracting appropriate indexes for the PMSM are proposed and discussed in this paper. The index-extracting techniques and their advantages, disadvantages, and significant ambiguities are proposed, and it is emphasized how these ambiguities can be eliminated. This can help the newcomers to this field as well as designers and manufacturers of protection and fault diagnosis industry. In light of this information, the readers will have a full view on different aspects of each index. An optimum index can be chosen based on the sensitivity of application and the cost of index implementation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Partial demagnetization causes asymmetric and unbalanced radial forces, resulting in high vibration and noise [28].”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [28]
Citations
Cites
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Transient analysis of cage induction machines under stator, rotor bar and end ring faults
Toliyat, H. A., & Lipo, T. A. (1995) · IEEE Transactions on Energy Conversion · doi:10.1109/60.391888 · Cited by 489
Design of Brushless Permanent-Magnet Machines
Hendershot, J. R., & Miller, T. J. E. (2010) · Medical Entomology and Zoology · Cited by 417
Kopp, N., Toliyat, H. A., & Kliman, G. B. (2010) · CRC Press eBooks · doi:10.1201/9781420030389 · Cited by 380
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Espinosa, A. G., Rosero, J. A., Cusido, J., Romeral, L., & Ortega, J. A. (2010) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2009.2037922 · Cited by 243
Ruiz, J.-R. R., García, J. R., Espinosa, A. G., & Romeral, L. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2015942 · Cited by 231
Hong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219
Lee, S. B., & Habetler, T. G. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.811789 · Cited by 202
Urresty, J.-C., Riba, J.-R., Delgado, M., & Romeral, L. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2011.2176127 · Cited by 181
Research works printed but not linked: 1
- miller, 2002, Speed’s Electric Motors
Cited by
Sorted by citations
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“The source of the PM temperature increase is the operation of the motor with a high load torque in difficult environmental conditions, but also damage to the stator winding in the form of ITSCs [15], [19], [20], [28]-[30], [32].”
BackgroundFaiz, J., & Mazaheri-Tehrani, E. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2608950 · Cited by 207
Self-citationHuang, F., Zhang, X., Qin, G., Xie, J., Peng, J., Huang, S., Long, Z., & Tang, Y. (2022) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2022.3165283 · Cited by 108
Skowron, M., Orłowska-Kowalska, T., & Kowalski, C. T. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3146557 · Cited by 106
Fault Detection and Diagnosis of the Electric Motor Drive and Battery System of Electric Vehicles
Khaneghah, M. Z., Alzayed, M., & Chaoui, H. (2023) · Machines · doi:10.3390/machines11070713 · Cited by 102
Metadata
- Authors
- Faiz, J., & Nejadi-Koti, H.
- Affiliations
- University of Tehran (IR)
- Venue
- IEEE Transactions on Magnetics
- Published
- 2016-04
- Volume
- 52
- Issue
- 4
- Pages
- 1-11
- ISSN
- 0018-9464 (ISSN-L)
- 1941-0069
- OpenAlex
- W2307389737
- Cited by
- 119
- References
- 36
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 16 · 2023: 14 · 2022: 14 · 2021: 16 · 2020: 17 · 2019: 11 · 2018: 9 · 2017: 6 · 2016: 3
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Magnetics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, demagnetization fault, fault diagnosis, fault index, fault sensitivity, motor protection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review