The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
A Gait Monitoring System Based on Air Pressure Sensors Embedded in a Shoe
Abstract
Measurement of ground contact forces (GCFs) provides necessary information to detect human gait phases. In this paper, a new analysis method of the GCF signals is discussed for detection of the gait phases. Human gaits are complicated, and the gait phases cannot be exactly distinguished by comparing sensor outputs to a threshold. This paper proposes a method by fuzzy logic for detecting the gait phases continuously and smoothly. The smooth and continuous detection of the gait phases enables a full use of information obtained from GCF sensors. For advanced rehabilitation systems, this paper also introduces a higher level algorithm that quantitatively monitors the amount of abnormalities in a human gait. The abnormalities detected by the proposed method include an improper GCF pattern as well as an incorrect sequence of the gait phases. To realize the monitoring algorithm, the gait phases are analyzed as a vector and the abnormalities are detected by simple kinematic equations. The proposed methods are implemented by using signals from sensor-embedded shoes called smart shoes. Each smart shoe has four GCF sensors installed between the cushion pad and the sole. The GCF sensor applies an air pressure sensor connected to an air bladder. A gait monitoring system that integrates the proposed methods is shown in this paper and verified for both normal and abnormal gaits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Mechanical Behavior of Materials
Hosford, W. F. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810923 · Cited by 1,218
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Gait Analysis Using a Shoe-Integrated Wireless Sensor System
Bamberg, S., Benbasat, A. Y., Scarborough, D. M., Krebs, D. E., & Paradiso, J. A. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899493 · Cited by 737
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495
Design and control of an exoskeleton for the elderly and patients
Kong, K., & Jeon, D. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.878550 · Cited by 403
Self-citationHayashi, T., Kawamoto, H., & Sankai, Y. (2005) · 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2005.1545505 · Cited by 377
Intelligent shoes for abnormal gait detection
Chen, M., Huang, B., & Xu, Y. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543503 · Cited by 122
A Wearable Biomechatronic Interface for Controlling Robots with Voluntary Foot Movements
Carrozza, M. C., Persichetti, A., Laschi, C., Vecchi, F., Lazzarini, R., Vacalebri, P., & Dario, P. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.886250 · Cited by 71
Gait Event Detection with Intelligent Shoes
Huang, B., Chen, M., Shi, X., & Xu, Y. (2007) · IEEE International Conference on Information Acquisition · doi:10.1109/icia.2007.4295799 · Cited by 44
Capacitive sensors for measuring the pressure between the foot and shoe
Kothari, M., Webster, J. G., Tompkins, W. J., Wertsch, J. J., & Bach‐y‐Rita, P. (1988) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1988.95056 · Cited by 35
Multi-dimensional vector product
Silagadze, Z. K. (2002) · Journal of Physics A Mathematical and General · doi:10.1088/0305-4470/35/23/310 · Cited by 27
ABNORMAL GAIT DETECTION USING INTELLIGENT SHOES
Chen, M., Huang, B., & Xu, Y. (2007) · International Journal of Information Acquisition · doi:10.1142/s0219878907001307 · Cited by 8
Cited by
From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized Healthcare
Andreu-Perez, J., Leff, D. R., Ip, H. M. D., & Yang, G.-Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2422751 · Cited by 383
Gait Partitioning Methods: A Systematic Review
Taborri, J., Palermo, E., Rossi, S., & Cappa, P. (2016) · Sensors · doi:10.3390/s16010066 · Cited by 361
Smart Insole: A Wearable Sensor Device for Unobtrusive Gait Monitoring in Daily Life
Lin, F., Wang, A., Zhuang, Y., Tomita, M. R., & Xu, W. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2585643 · Cited by 265
Gait phase analysis based on a Hidden Markov Model
Bae, J., & Tomizuka, M. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2011.03.003 · Cited by 106
Self-citationPersonalized Human Activity Recognition Based on Integrated Wearable Sensor and Transfer Learning
Fu, Z., He, X., Wang, E., Huo, J., Huang, J., & Wu, D. (2021) · Sensors · doi:10.3390/s21030885 · Cited by 79
“Therefore, using an external airbag and air pressure sensor to detect muscle deformation can obtain muscle movement information for posture recognition [24,25].”
Background
Metadata
- Authors
- Kong, K., & Tomizuka, M.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2009-06
- Volume
- 14
- Issue
- 3
- Pages
- 358-370
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2047993060
- Cited by
- 301
- References
- 13
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.