The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Novel Gait Adaptation and Neuromotor Training Results Using an Active Leg Exoskeleton
Abstract
The gait of every adult is unique and expected to be ingrained within the neuromuscular system. The major scientific question that we ask in this paper if it is possible to alter the gait of healthy individuals using special purpose design of robots and training paradigms. This paper describes novel experimental results with an active leg exoskeleton (ALEX) and a force-field controller (FFC) developed for neuromotor training of gait and rehabilitation of patients with walking disabilities. ALEX is a motorized leg orthosis having a total of 7 DOFs with hip and knee actuated in the sagittal plane. The FFC applies forces on the foot to help the leg move on a desired trajectory. The interaction forces between the subject and the orthosis are designed to be ¿assist-as-needed¿ for safe and effective gait training. Simulations and experimental results with the FFC are presented. Experiments have been performed on six healthy subjects walking on a treadmill. It was shown that a healthy subject could be retrained in about 45 min with ALEX to walk on a treadmill with a considerably altered gait. In the coming months, this powered orthosis will be used for gait training of stroke patients.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The effectiveness of ALEX has been demonstrated through clinical trials with stroke survivors [28], [29].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [29]
In the citing paper
“After training with ALEX, the patients' gait pattern are closer to a healthy gait pattern with increased gait size and walking speeds.”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [29]
Citations
Cites
Armstrong-Hélouvry, B., Dupont, P. E., & de Wit, C. C. (1994) · Automatica · doi:10.1016/0005-1098(94)90209-7 · Cited by 2,683
O’Rourke, J., & Mallinckrodt, A. J. (1995) · Computers in Physics · doi:10.1063/1.4823371 · Cited by 1,202
Treadmill training of paraplegic patients using a robotic orthosis.
Colombo, G., Joerg, M., Schreier, R., & Dietz, V. (2000) · PubMed · Cited by 1,114
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Patient- cooperative strategies for robot-aided treadmill training: first experimental results
Riener, R., Lunenburger, L., Jezernik, S., Anderschitz, M., Colombo, G., & Dietz, V. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848628 · Cited by 729
Motor learning elicited by voluntary drive
Lotze, M. (2003) · Brain · doi:10.1093/brain/awg079 · Cited by 691
Veneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2006) · The International Journal of Robotics Research · doi:10.1177/0278364906063829 · Cited by 428
Husemann, B., Müller, F., Krewer, C., Heller, S., & Koenig, E. (2007) · Stroke · doi:10.1161/01.str.0000254607.48765.cb · Cited by 418
A mechanized gait trainer for restoration of gait.
Hesse, S., & Uhlenbrock, D. (2001) · PubMed · Cited by 390
Power assist method based on Phase Sequence and muscle force condition for HAL
Kawamoto, H., & Sankai, Y. (2005) · Advanced Robotics · doi:10.1163/1568553054455103 · Cited by 376
Mayr, A., Kofler, M., Quirbach, E., Matzak, H., Fröhlich, K., & Saltuari, L. (2007) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307300697 · Cited by 371 · cited 1×
“Lokomat has been used in gait training studies [23] [24].”
MethodCai, L. L., Fong, A. J., Otoshi, C. K., Liang, Y., Burdick, J. W., Roy, R. R., & Edgerton, V. R. (2006) · Journal of Neuroscience · doi:10.1523/jneurosci.2266-06.2006 · Cited by 345
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
Banala, S. K., Agrawal, S. K., & Scholz, J. P. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428456 · Cited by 320
Mechanical performance of artificial pneumatic muscles to power an ankle–foot orthosis
Gordon, K. E., Sawicki, G. S., & Ferris, D. P. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.018 · Cited by 223
HapticWalker---a novel haptic foot device
Schmidt, H., Hesse, S., Bernhardt, R., & Krüger, J. (2005) · ACM Transactions on Applied Perception · doi:10.1145/1060581.1060589 · Cited by 200
Gravity-Balancing Leg Orthosis and Its Performance Evaluation
Banala, S. K., Agrawal, S. K., Fattah, A., Krishnamoorthy, V., Hsu, W., Scholz, J. F., & Rudolph, K. S. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.882928 · Cited by 199
A mechanized gait trainer for restoring gait in nonambulatory subjects
Hesse, S., Uhlenbrock, D., Werner, C., & Bardeleben, A. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.6280 · Cited by 193
Role of voluntary drive in encoding an elementary motor memory.
Kaelin-Lang, A., Sawaki, L., & Cohen, L. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00143.2004 · Cited by 182
Assessment of Motion of a Swing Leg and Gait Rehabilitation With a Gravity Balancing Exoskeleton
Agrawal, S. K., Banala, S. K., Fattah, A., Sangwan, V., Krishnamoorthy, V., Scholz, J. P., & Hsu, W. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903930 · Cited by 152
Nikitczuk, J., Weinberg, B., & Mavroidis, C. (2007) · Smart Materials and Structures · doi:10.1088/0964-1726/16/2/021 · Cited by 63
Albu‐Schäffer, A., Bertleff, W., Rebele, B., Schäfer, B., Landzettel, K., & Hirzinger, G. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642296 · Cited by 61
An Assistive Robotic Device That Can Synchronize to the Pelvic Motion During Human Gait Training
Aoyagi, D., Ichinose, W. E., Harkema, S. J., Reinkensmeyer, D. J., & Bobrow, J. E. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1502026 · Cited by 56
Friction compensation for a force-feedback telerobotic system
Mahvash, M., & Okamura, A. M. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1642200 · Cited by 41
Differentially Flat Design of Bipeds Ensuring Limit Cycles
Sangwan, V., & Agrawal, S. K. (2009) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2009.2033593 · Cited by 31
The Analysis, Design and Implementation of a Model of an Exoskeleton to Support Mobility
Acosta-Marquez, C., & Bradley, D. A. (2005) · doi:10.1109/icorr.2005.1501061 · Cited by 30
Motion control of a novel planar biped with nearly linear dynamics
Agrawal, S. K., & Fattah, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871091 · Cited by 24
Learned Helplessness: Performance as a Function of Task Significance
Skinner, N. F. (1979) · The Journal of Psychology · doi:10.1080/00223980.1979.9915097 · Cited by 21
Novel swing-assist un-motorized exoskeletons for gait training
Mankala, K. K., Banala, S. K., & Agrawal, S. K. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-24 · Cited by 20
Task performance in spinal cord injury: effect of helplessness training.
Wool, R., Siegel, D., & Fine, P. R. (1980) · PubMed · Cited by 20
Biomechanical Modelling of the Upper Limb for Robotics-Based Orthotic Tremor Suppression
Rocon, E., Ruiz, A. F., & Pons, J. L. (2005) · Applied Bionics and Biomechanics · doi:10.1155/2005/535893 · Cited by 18
Associates, W., & Springs, Y. (1978) · Medical Entomology and Zoology · Cited by 12
12.12 Locomotor training with a driven gait orthosis inincomplete spinal cord injury
Wirz, M., Hornby, T. G., Rupp, R., & Dietz, V. (2005) · Gait & Posture · doi:10.1016/s0966-6362(05)80242-5 · Cited by 7
Garretson, J., Becker, W. T., & Dubowsky, S. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2006.1641157 · Cited by 6
Research works printed but not linked: 2
- perry, 1989, Observational Gait Analysis Handbook
- mankala, 2009, novel swing-assist unmotorized exoskeletons for gait training, J Neuro Eng Rehabil, 6
Cited by
Sorted by citations
A Review on Lower Limb Rehabilitation Exoskeleton Robots
Shi, D., Zhang, W., Zhang, W., & Ding, X. (2019) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-019-0389-8 · Cited by 534
Recent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“The effectiveness of ALEX has been demonstrated through clinical trials with stroke survivors [28,29].”
BackgroundLower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2014) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 461
Bôrtole, M., Venkatakrishnan, A., Zhu, F., Moreno, J. C., Francisco, G. E., Pons, J. L., & Contreras-Vidal, J. L. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0048-y · Cited by 347
Robotic gait rehabilitation and substitution devices in neurological disorders: where are we now?
Calabrò, R. S., Cacciola, A., Bertè, F., Manuli, A., Leo, A., Bramanti, A., Naro, A., Milardi, D., & Bramanti, P. (2016) · Neurological Sciences · doi:10.1007/s10072-016-2474-4 · Cited by 271
Metadata
- Authors
- Banala, S. K., Agrawal, S. K., Kim, S. H., & Scholz, J. P.
- Affiliations
- University of Delaware (US)
- University of South Florida (US)
- ORCID
- Agrawal, S.K.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2010-04
- Volume
- 15
- Issue
- 2
- Pages
- 216-225
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2099726059
- Cited by
- 165
- References
- 33
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 11 · 2023: 9 · 2022: 11 · 2021: 12 · 2020: 13 · 2019: 17 · 2018: 14 · 2017: 12 · 2016: 7 · 2015: 13 · 2014: 11 · 2013: 11 · 2012: 6
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE/ASME Transactions on Mechatronics (publishedVersion)
- The Royal Society of Chemistry’s Journals, Books and Databases (The Royal Society of Chemistry) (submittedVersion)
- Funders
- National Center for Medical Rehabilitation Research
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- gait adaptation, treadmill walking, powered orthosis, stroke rehabilitation, gait rehabilitation, assist-as-needed control, healthy volunteers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review