Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 204

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Design of a 7-DOF Cable-Driven Arm Exoskeleton (CAREX-7) and a Controller for Dexterous Motion Training or Assistance

Cui, Xiang, Chen, Weihai, Jin, Xin, Agrawal, Sunil K. · 2017 · IEEE/ASME Transactions on Mechatronics

Abstract

The training for both translation and rotation of the hand is desirable for patients with impairments. This paper focuses on the design and control of a 7-degree-of-freedom cable-driven arm exoskeleton (CAREX-7), used for dexterous motion (including translation and rotation) training or assistance of the whole-arm. The CAREX-7 includes an additional wrist module compared with CAREX, and eight cables are routed through the exoskeleton cuffs to drive the whole-arm motion. Based on the “assist-as-needed” paradigm, a novel wrench-field controller was designed to regulate a needed wrench (force and torque) on the hand for assisting its dexterous manipulation. Healthy subjects participated in path-tracking experiments while wearing CAREX-7. The experimental results show that the CAREX-7 with the new wrench-field controller can help the subjects to follow the path more closely, and this demonstrates the effectiveness of the device. The current design of CAREX-7 is unique and offers significant improvements and new functionality over the existing CAREX. The novel features are the following: 1) CAREX-7 is an exoskeleton for the full human arm, including shoulder, elbow, and the wrist, with new design issues; and 2) controller of CAREX-7 builds on a screw-theoretic approach and assists both translation and rotation of the hand, allowing for dexterous hand reorientation, which is required in everyday tasks.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmech.2016.2618888

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 204

Metadata

Authors
Cui, X., Chen, W., Jin, X., & Agrawal, S. K.
Venue
IEEE/ASME Transactions on Mechatronics
Published
2017-02
Volume
22
Issue
1
Pages
161-172
ISSN
  • 1083-4435 (ISSN-L)
  • 1941-014X
OpenAlex
W2533599559
Cited by
204
References
2
FWCI
7.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design of a 7-DOF Cable-Driven Arm Exoskeleton (CAREX-7) and a Controller for Dexterous Motion Training or Assistance. https://app.cochat.ai/papers/10.1109/tmech.2016.2618888
The paper
Cui, X., Chen, W., Jin, X., & Agrawal, S. K. (2017). Design of a 7-DOF Cable-Driven Arm Exoskeleton (CAREX-7) and a Controller for Dexterous Motion Training or Assistance. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2016.2618888

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.