The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Design of a 7-DOF Cable-Driven Arm Exoskeleton (CAREX-7) and a Controller for Dexterous Motion Training or Assistance
Abstract
The training for both translation and rotation of the hand is desirable for patients with impairments. This paper focuses on the design and control of a 7-degree-of-freedom cable-driven arm exoskeleton (CAREX-7), used for dexterous motion (including translation and rotation) training or assistance of the whole-arm. The CAREX-7 includes an additional wrist module compared with CAREX, and eight cables are routed through the exoskeleton cuffs to drive the whole-arm motion. Based on the “assist-as-needed” paradigm, a novel wrench-field controller was designed to regulate a needed wrench (force and torque) on the hand for assisting its dexterous manipulation. Healthy subjects participated in path-tracking experiments while wearing CAREX-7. The experimental results show that the CAREX-7 with the new wrench-field controller can help the subjects to follow the path more closely, and this demonstrates the effectiveness of the device. The current design of CAREX-7 is unique and offers significant improvements and new functionality over the existing CAREX. The novel features are the following: 1) CAREX-7 is an exoskeleton for the full human arm, including shoulder, elbow, and the wrist, with new design issues; and 2) controller of CAREX-7 builds on a screw-theoretic approach and assists both translation and rotation of the hand, allowing for dexterous hand reorientation, which is required in everyday tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 1×
“Research performed with robotic training devices, introduced during the last two decades, show that these devices are effective in motor rehabilitation and can potentially reduce the expense of treatment [2].”
BackgroundRobot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Cited by
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Wang, Y., Peng, J., Zhu, K., Chen, B., & Wu, H. (2020) · International Journal of Systems Science · doi:10.1080/00207721.2020.1808732 · Cited by 21
Metadata
- Authors
- Cui, X., Chen, W., Jin, X., & Agrawal, S. K.
- Venue
- IEEE/ASME Transactions on Mechatronics
- Published
- 2017-02
- Volume
- 22
- Issue
- 1
- Pages
- 161-172
- ISSN
- 1083-4435 (ISSN-L)
- 1941-014X
- OpenAlex
- W2533599559
- Cited by
- 204
- References
- 2
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of a 7-DOF Cable-Driven Arm Exoskeleton (CAREX-7) and a Controller for Dexterous Motion Training or Assistance. https://app.cochat.ai/papers/10.1109/tmech.2016.2618888
- The paper
- Cui, X., Chen, W., Jin, X., & Agrawal, S. K. (2017). Design of a 7-DOF Cable-Driven Arm Exoskeleton (CAREX-7) and a Controller for Dexterous Motion Training or Assistance. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2016.2618888
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.