The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Consistent landmark and intensity-based image registration
Abstract
Two new consistent image registration algorithms are presented: one is based on matching corresponding landmarks and the other is based on matching both landmark and intensity information. The consistent landmark and intensity registration algorithm produces good correspondences between images near landmark locations by matching corresponding landmarks and away from landmark locations by matching the image intensities. In contrast to similar unidirectional algorithms, these new consistent algorithms jointly estimate the forward and reverse transformation between two images while minimizing the inverse consistency error-the error between the forward (reverse) transformation and the inverse of the the reverse (forward) transformation. This reduces the ambiguous correspondence between the forward and reverse transformations associated with large inverse consistency errors. In both algorithms a thin-plate spline (TPS) model is used to regularize the estimated transformations. Two-dimensional (2-D) examples are presented that show the inverse consistency error produced by the traditional unidirectional landmark TPS algorithm can be relatively large and that this error is minimized using the consistent landmark algorithm. Results using 2-D magnetic resonance imaging data are presented that demonstrate that using landmark and intensity information together produce better correspondence between medical images than using either landmarks or intensity information alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Morphometric Tools for Landmark Data: Geometry and Biology
Bookstein, F. L. (1992) · Cambridge University Press eBooks · doi:10.1017/cbo9780511573064 · Cited by 4,365
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Automated Image Registration: I. General Methods and Intrasubject, Intramodality Validation
Woods, R. P., Grafton, S. T., Holmes, C. J., Cherry, S. R., & Mazziotta, J. C. (1998) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199801000-00027 · Cited by 1,707
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Lectu re Notes in Biomathematics
Levin, S. A. (1983) · Cited by 1,572
Morphometric Tools for Landmark Data.
Bookstein, F. (1998) · Biometrics · doi:10.2307/2534038 · Cited by 1,378
Deformable templates using large deformation kinematics
Christensen, G. E., Rabbitt, R. D., & Miller, M. I. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.536892 · Cited by 1,142
Self-citationMultiresolution elastic matching
Bajcsy, R., & Kovačič, S. (1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(89)80014-3 · Cited by 1,106
Research works printed but not linked: 10
- Bookstein, 1978, Lecture Notes in Biomathematics, 24
- 10.1016/B978-012692535-7/50090-2 · DOI
- 10.1117/12.348618 · doi:10.1117/12.348618
- 10.1016/B978-012692535-7/50086-0 · doi:10.1016/b978-012692535-7/50086-0
- Kent, 1994, The link between kriging and thin-plate splines
- 10.1117/12.131082 · doi:10.1117/12.131082
- Joshi, 1997, Large deformation diffeomorphisms and gaussian random fields for statistical characterization of brain sub-manifolds
- Johnson, 2000, Method for consistent linear-elastic medical image registration
- Toga, 1999, Academic
- Johnson, 2000, Image registration methods for the synthesis and evaluation of anatomical population summaries
Cited by
AVANTS, B., EPSTEIN, C., GROSSMAN, M., & GEE, J. (2008) · Medical Image Analysis · doi:10.1016/j.media.2007.06.004 · Cited by 5,669
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Self-citationDeformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Johnson and Christensen’s consistent registration approach [379] as well as Rueckert et al.”
BackgroundMethodConstruction of a 3D probabilistic atlas of human cortical structures
Shattuck, D. W., Mirza, M., Adisetiyo, V., Hojatkashani, C., Salamon, G., Narr, K. L., Poldrack, R. A., Bilder, R. M., & Toga, A. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.031 · Cited by 1,203
TransMorph: Transformer for unsupervised medical image registration
Chen, J., Frey, E. C., He, Y., Segars, W. P., Li, Y., & Du, Y. (2022) · Medical Image Analysis · doi:10.1016/j.media.2022.102615 · Cited by 804
Non-rigid image registration: theory and practice
Crum, W. R., Hartkens, T., & Hill, D. L. G. (2004) · The British Journal of Radiology · doi:10.1259/bjr/25329214 · Cited by 719
A Review of Geometric Transformations for Nonrigid Body Registration
Holden, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904691 · Cited by 369
Integrating spatial configuration into heatmap regression based CNNs for landmark localization
Payer, C., Štern, D., Bischof, H., & Urschler, M. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.007 · Cited by 365
Elastic Registration of Biological Images Using Vector-Spline Regularization
Sorzano, C. O. S., Thevenaz, P., & Unser, M. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844030 · Cited by 323
Reinhardt, J. M., Ding, K., Cao, K., Christensen, G. E., Hoffman, E. A., & Bodas, S. V. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.03.007 · Cited by 322
Self-citationA framework to study the cortical folding patterns
Mangin, J.-F., Rivière, D., Cachia, A., Duchesnay, E., Cointepas, Y., Papadopoulos-Orfanos, D., Scifo, P., Ochiai, T., Brunelle, F., & Régis, J. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.019 · Cited by 305
Birnet: Brain image registration using dual-supervised fully convolutional networks
Fan, J., Cao, X., Yap, P.-T., & Shen, D. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.006 · Cited by 297
Brain Functional Localization: A Survey of Image Registration Techniques
Gholipour, A., Kehtarnavaz, N., Briggs, R., Devous, M., & Gopinath, K. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.892508 · Cited by 274
Evaluating fMRI preprocessing pipelines
Strother, S. C. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1607667 · Cited by 169
“As a possible means of addressing this surprising result, a number of groups are exploring the use of intensitybased algorithms with additional anatomical constraints, such as major sulcal landmarks or automatically generated features [106]–[108].”
BackgroundLearning to detect anatomical landmarks of the pelvis in X-rays from arbitrary views
Bier, B., Goldmann, F., Zaech, J.-N., Fotouhi, J., Hegeman, R., Grupp, R., Armand, M., Osgood, G., Navab, N., Maier, A., et al. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-01975-5 · Cited by 43
Fiducial-Free 2D/3D Registration for Robot-Assisted Femoroplasty
Gao, C., Farvardin, A., Grupp, R. B., Bakhtiarinejad, M., Ma, L., Thies, M., Unberath, M., Taylor, R. H., & Armand, M. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2020.3012460 · Cited by 36
Abumoussa, A., Gopalakrishnan, V., Succop, B., Galgano, M., Jaikumar, S., Lee, Y. Z., & Bhowmick, D. A. (2023) · Neurosurgical Focus · doi:10.3171/2023.3.focus2345 · Cited by 9
Metadata
- Authors
- Johnson, H. J., & Christensen, G. E.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-05
- Volume
- 21
- Issue
- 5
- Pages
- 450-461
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2146497006
- Cited by
- 399
- References
- 31
- FWCI
- 18.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.