Left ventricular volume estimation for real-time three-dimensional echocardiography
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The application of level set techniques to echocardiographic data is presented. This method allows semiautomatic segmentation of heart chambers, which regularizes the shapes and improves edge fidelity, especially in the presence of gaps, as is common in ultrasound data. The task of the study was to reconstruct left ventricular shape and to evaluate left ventricular volume. Data were acquired with a real-time three-dimensional (3-D) echocardiographic system. The method was applied directly in the three-dimensional domain and was based on a geometric-driven scheme. The numerical scheme for solving the proposed partial differential equation is borrowed from numerical methods for conservation law. Results refer to in vitro and human in vivo acquired 3-D + time echocardiographic data. Quantitative validation was performed on in vitro balloon phantoms. Clinical application of this segmentation technique is reported for 20 patient cases providing measures of left ventricular volumes and ejection fraction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
“Corsi et al. [61] presented a level set based segmentation approach which was applied to real-time 3D echocardiography from a Volumetrics system.”
BackgroundMethodZheng, Y., Barbu, A., Georgescu, B., Scheuering, M., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004421 · Cited by 546
Sugeng, L., Mor-Avi, V., Weinert, L., Niel, J., Ebner, C., Steringer-Mascherbauer, R., Schmidt, F., Galuschky, C., Schummers, G., Lang, R. M., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.626143 · Cited by 459
High-resolution transthoracic real-time three-dimensional echocardiography
Kühl, H. P., Schreckenberg, M., Rulands, D., Katoh, M., Schäfer, W., Schummers, G., Bücker, A., Hanrath, P., & Franke, A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.01.037 · Cited by 296
Corsi, C., Lang, R. M., Veronesi, F., Weinert, L., Caiani, E. G., MacEneaney, P., Lamberti, C., & Mor-Avi, V. (2005) · Circulation · doi:10.1161/circulationaha.104.513689 · Cited by 244
Self-citation
Metadata
- Authors
- Corsi, C., Saracino, G., Sarti, A., & Lamberti, C.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-09
- Volume
- 21
- Issue
- 9
- Pages
- 1202-1208
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2155728526
- Cited by
- 115
- References
- 2
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left ventricular volume estimation for real-time three-dimensional echocardiography. https://app.cochat.ai/papers/10.1109/tmi.2002.804418
- The paper
- Corsi, C., Saracino, G., Sarti, A., & Lamberti, C. (2002). Left ventricular volume estimation for real-time three-dimensional echocardiography. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2002.804418
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.