The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Four-Chamber Heart Modeling and Automatic Segmentation for 3-D Cardiac CT Volumes Using Marginal Space Learning and Steerable Features
Abstract
We propose an automatic four-chamber heart segmentation system for the quantitative functional analysis of the heart from cardiac computed tomography (CT) volumes. Two topics are discussed: heart modeling and automatic model fitting to an unseen volume. Heart modeling is a nontrivial task since the heart is a complex nonrigid organ. The model must be anatomically accurate, allow manual editing, and provide sufficient information to guide automatic detection and segmentation. Unlike previous work, we explicitly represent important landmarks (such as the valves and the ventricular septum cusps) among the control points of the model. The control points can be detected reliably to guide the automatic model fitting process. Using this model, we develop an efficient and robust approach for automatic heart chamber segmentation in 3-D CT volumes. We formulate the segmentation as a two-step learning problem: anatomical structure localization and boundary delineation. In both steps, we exploit the recent advances in learning discriminative models. A novel algorithm, marginal space learning (MSL), is introduced to solve the 9-D similarity transformation search problem for localizing the heart chambers. After determining the pose of the heart chambers, we estimate the 3-D shape through learning-based boundary delineation. The proposed method has been extensively tested on the largest dataset (with 323 volumes from 137 patients) ever reported in the literature. To the best of our knowledge, our system is the fastest with a speed of 4.0 s per volume (on a dual-core 3.2-GHz processor) for the automatic segmentation of all four chambers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190
Cootes, T. F., Edwards, G. J., & Taylor, C. J. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.927467 · Cited by 5,409
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Improved boosting algorithms using confidence-rated predictions
Schapire, R. E., & Singer, Y. (1998) · Proceedings of the eleventh annual conference on Computational learning theory · doi:10.1145/279943.279960 · Cited by 2,547
Learning to detect natural image boundaries using local brightness, color, and texture cues
Martin, D. R., Fowlkes, C. C., & Malik, J. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.1273918 · Cited by 2,420
Improved Boosting Algorithms Using Confidence-rated Predictions
Schapire, R. E., & Singer, Y. (1999) · Machine Learning · doi:10.1023/a:1007614523901 · Cited by 1,971
Pedestrian detection using wavelet templates
Oren, M., Papageorgiou, C., Sinha, P., Osuna, E., & Poggio, T. (2002) · Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1997.609319 · Cited by 695
A minimum description length approach to statistical shape modeling
Davies, R. H., Twining, C. J., Cootes, T. F., Waterton, J. C., & Taylor, C. J. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009388 · Cited by 572
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
Research works printed but not linked: 11
- 10.1007/s11263-006-7936-3 · doi:10.1007/s11263-006-7936-3
- 10.1109/6104.956807 · doi:10.1109/6104.956807
- neubauer, 2003, analysis of four-dimensional cardiac data sets using skeleton-based segmentation, Proc Int Conf Central Eur Comput Graphics Visualizat
- zheng, 2008, four-chamber heart modeling and automatic segmentation for 3-d cardiac ct volumes, Proc SPIE Med Imag, 10.1109/TMI.2008.2004421
- ecabert, 2006, modeling shape variability for full heart segmentation in cardiac computed-tomography images, Proc SPIE Med Imag, 1199
- 10.1006/cviu.1999.0814 · doi:10.1006/cviu.1999.0814
- fritz, 2005, automatic segmentation of the left ventricle and computation of diagnostic parameters using regiongrowing and a statistical model, Proc SPIE Med Imag, 1844, 10.1117/12.595071 · doi:10.1117/12.595071
- 10.3949/ccjm.72.2.127 · doi:10.3949/ccjm.72.2.127
- lu, 2008, automatic detection of standard planes from three dimensional echocardiographic data, Proc 1st IEEE Int Symp Biomed Imag, 1279
- 10.1145/1042091.1042118 · doi:10.1145/1042091.1042118
- 10.1109/TMI.2002.804435 · doi:10.1109/tmi.2002.804435
Cited by
Deep Learning for Cardiac Image Segmentation: A Review
Chen, C., Qin, C., Qiu, H., Tarroni, G., Duan, J., Bai, W., & Rueckert, D. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00025 · Cited by 869
Deep Learning in Medical Ultrasound Analysis: A Review
Liu, S., Wang, Y., Yang, X., Lei, B., Liu, L., Li, S. X., Ni, D., & Wang, T. (2019) · Engineering · doi:10.1016/j.eng.2018.11.020 · Cited by 798
Artificial Intelligence in Cardiovascular Imaging
Dey, D., Slomka, P. J., Leeson, P., Comaniciu, D., Shrestha, S., Sengupta, P. P., & Marwick, T. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.054 · Cited by 680
Self-citation3D deeply supervised network for automated segmentation of volumetric medical images
Dou, Q., Yu, L., Chen, H., Jin, Y., Yang, X., Qin, J., & Heng, P.-A. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.05.001 · Cited by 613
Multi-scale patch and multi-modality atlases for whole heart segmentation of MRI
Zhuang, X., & Shen, J. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.02.006 · Cited by 502
Metadata
- Authors
- Zheng, Y., Barbu, A., Georgescu, B., Scheuering, M., & Comaniciu, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-11
- Volume
- 27
- Issue
- 11
- Pages
- 1668-1681
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2101689475
- Cited by
- 546
- References
- 34
- FWCI
- 46.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Four-Chamber Heart Modeling and Automatic Segmentation for 3-D Cardiac CT Volumes Using Marginal Space Learning and Steerable Features. https://app.cochat.ai/papers/10.1109/tmi.2008.2004421
- The paper
- Zheng, Y., Barbu, A., Georgescu, B., Scheuering, M., & Comaniciu, D. (2008). Four-Chamber Heart Modeling and Automatic Segmentation for 3-D Cardiac CT Volumes Using Marginal Space Learning and Steerable Features. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2008.2004421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.