The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
3-D active appearance models: segmentation of cardiac MR and ultrasound images
Abstract
A model-based method for three-dimensional image segmentation was developed and its performance assessed in segmentation of volumetric cardiac magnetic resonance (MR) images and echocardiographic temporal image sequences. Comprehensive design of a three-dimensional (3-D) active appearance model (AAM) is reported for the first time as an involved extension of the AAM framework introduced by Cootes et al. The model's behavior is learned from manually traced segmentation examples during an automated training stage. Information about shape and image appearance of the cardiac structures is contained in a single model. This ensures a spatially and/or temporally consistent segmentation of three-dimensional cardiac images. The clinical potential of the 3-D AAM is demonstrated in short-axis cardiac MR images and four-chamber echocardiographic sequences. The method's performance was assessed by comparison with manually identified independent standards in 56 clinical MR and 64 clinical echo image sequences. The AAM method showed good agreement with the independent standard using quantitative indexes of border positioning errors, endo- and epicardial volumes, and left ventricular mass. In MR, the endocardial volumes, epicardial volumes, and left ventricular wall mass correlation coefficients between manual and AAM were R2 = 0.94, 0.97, 0.82, respectively. For echocardiographic analysis, the area correlation was R2 = 0.79. The AAM method shows high promise for successful application to MR and echocardiographic image analysis in a clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190
Cootes, T. F., Edwards, G. J., & Taylor, C. J. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.927467 · Cited by 5,409
Morphometric Tools for Landmark Data: Geometry and Biology
Bookstein, F. L. (1992) · Cambridge University Press eBooks · doi:10.1017/cbo9780511573064 · Cited by 4,365
Image Processing, Analysis and Machine Vision
Sonka, M., Hlavac, V., & Boyle, R. (1993) · Springer eBooks · doi:10.1007/978-1-4899-3216-7 · Cited by 3,717
Self-citationProcrustes Methods in the Statistical Analysis of Shape
Goodall, C. (1991) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1991.tb01825.x · Cited by 2,047
Image processing, analysis and machine vision
Saarinen, K. (1994) · Signal Processing · doi:10.1016/0165-1684(94)90202-x · Cited by 1,498
Morphometric Tools for Landmark Data.
Bookstein, F. (1998) · Biometrics · doi:10.2307/2534038 · Cited by 1,378
Rotations, quaternions, and double groups
Altmann, S. L. (1986) · Cited by 771
Parametrization of Closed Surfaces for 3-D Shape Description
Brechbühler, C., Gerig, G., & Kübler, O. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1013 · Cited by 681
A minimum description length approach to statistical shape modeling
Davies, R. H., Twining, C. J., Cootes, T. F., Waterton, J. C., & Taylor, C. J. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009388 · Cited by 572
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
Interpreting face images using active appearance models
Edwards, G. J., Taylor, C. J., & Cootes, T. F. (2002) · Proceedings Third IEEE International Conference on Automatic Face and Gesture Recognition · doi:10.1109/afgr.1998.670965 · Cited by 484
Elastic model-based segmentation of 3-D neuroradiological data sets
Kelemen, A., Szekely, G., & Gerig, G. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811260 · Cited by 434
Equivalence and efficiency of image alignment algorithms
Baker, S., & Matthews, I. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990652 · Cited by 406
Mitchell, S. C., Lelieveldt, B. P. F., van der Geest, R. J., Bosch, H. G., Reiver, J. H. C., & Sonka, M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.925294 · Cited by 332
Self-citationImage processing analysis and machine vision [2nd ed.]
Sonka, M., Hlaváč, V., & Boyle, R. (1999) · Cited by 329
Self-citationAutomatic segmentation of echocardiographic sequences by active appearance motion models
Bosch, J. G., Mitchell, S. C., Lelieveldt, B. P. F., Nijland, F., Kamp, O., Sonka, M., & Reiber, J. H. C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806427 · Cited by 296
Self-citationModel-based deformable surface finding for medical images
Staib, L. H., & Duncan, J. S. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538949 · Cited by 228
van der Geest, R. J., Buller, V. G. M., Jansen, E., Lamb, H. J., Baur, L. H. B., van der Wall, E. E., Roos, A., & Reiber, J. H. C. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199709000-00019 · Cited by 216
Self-citationSegmentation and interpretation of MR brain images. An improved active shape model
Duta, N., & Sonka, M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746716 · Cited by 193
Self-citationShen, D., Herskovits, E. H., & Davatzikos, C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921475 · Cited by 178
Trainable method of parametric shape description
Cootes, T. F., Cooper, D. H., Taylor, C. J., & Graham, J. (1992) · Image and Vision Computing · doi:10.1016/0262-8856(92)90044-4 · Cited by 165
A unified framework for atlas matching using active appearance models
Cootes, Beeston, Edwards, & Taylor (1999) · Information Processing in Medical Imaging · Cited by 141
Constrained active appearance models
Cootes, T. F., & Taylor, C. (2002) · IEEE/CVF International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2001.937601 · Cited by 131
A Unified Framework for Atlas Matching Using Active Appearance Models
Cootes, T. F., Beeston, C., Edwards, G. J., & Taylor, C. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48714-x_24 · Cited by 131
Automatic construction of 2D shape models
Duta, N., Jain, A. K., & Dubuisson-Jolly, M.-P. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.922703 · Cited by 86
Anisotropic filtering for model-based segmentation of 4D cylindrical echocardiographic images
Montagnat, J., Maxime Sermesant, B., Delingette, H., et al. (2002) · Pattern Recognition Letters · doi:10.1016/s0167-8655(02)00184-8 · Cited by 81
Multiresolution stochastic hybrid shape models with fractal priors
Vemuri, B. C., & Radisavljevic, A. (1994) · ACM Transactions on Graphics · doi:10.1145/176579.176583 · Cited by 74
Evaluating a robust contour tracker on echocardiographic sequences
Jacob, G., Noble, J. A., Mulet-Parada, M., & Blake, A. (1999) · Medical Image Analysis · doi:10.1016/s1361-8415(99)80017-6 · Cited by 68
Robust point correspondence applied to two- and three-dimensional image registration
Guest, E., Berry, E., Baldock, R., Fidrich, M., & Smith, M. A. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.908967 · Cited by 66
A Minimum Description Length Approach to Statistical Shape Modelling
Davies, R. H., Cootes, T. F., & Taylor, C. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45729-1_5 · Cited by 42
Cited by
Bernard, O., Lalande, A., Zotti, C., Cervenansky, F., Yang, X., Heng, P.-A., Cetin, I., Lekadir, K., Camara, O., Gonzalez Ballester, M. A., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2837502 · Cited by 2,431
Statistical shape models for 3D medical image segmentation: A review
Heimann, T., & Meinzer, H.-P. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.05.004 · Cited by 1,417
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
A review of segmentation methods in short axis cardiac MR images
Petitjean, C., & Dacher, J.-N. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.12.004 · Cited by 737
Machine learning and radiology
Wang, S., & Summers, R. M. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.02.005 · Cited by 697
Metadata
- Authors
- Mitchell, S. C., Bosch, J. G., Lelieveldt, B. P. F., van der Geest, R. J., Reiber, J. H. C., & Sonka, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2002-09
- Volume
- 21
- Issue
- 9
- Pages
- 1167-1178
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2032051785
- Cited by
- 392
- References
- 32
- FWCI
- 24.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.