CoChat

Cone-beam reprojection using projection-matrices

Galigekere, R.R., Wiesent, K., Holdsworth, D.W. · 2003 · IEEE Transactions on Medical Imaging
Cited by 59

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

This paper addresses reprojection of three-dimensional (3-D) reconstructions obtained from cone-beam scans using a C-arm imaging equipment assisted by a pose-determining system. The emphasis is on reprojecting without decomposing the estimated projection matrix (P-matrix) associated with a pose. Both voxel- and ray-driven methods are considered. The voxel-driven reprojector follows the algorithm for backprojection using a P-matrix. The ray-driven reprojector is derived by extracting from the P-matrix the equation of the line joining a detector-pixel and the X-ray source position. This reprojector can be modified to a ray-driven backprojector. When the geometry is specified explicitly in terms of the physical parameters of the imaging system, the projection matrices can be constructed. The resulting "projection-matrix method" is advantageous, especially when the scanning trajectory is irregular. The algorithms presented are useful in iterative methods of image reconstruction and enhancement procedures, apart from their well-known role in visualization and volume rendering. Reprojections of 3-D patient data compare favorably with the original X-ray projections obtained from a prototype C-arm system. The algorithms for reprojection can be modified to compute perspective maximum intensity projection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2003.817787

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 59

Metadata

Authors
Galigekere, R. R., Wiesent, K., & Holdsworth, D. W.
Venue
IEEE Transactions on Medical Imaging
Published
2003-10
Volume
22
Issue
10
Pages
1202-1214
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2111338112
Cited by
59
References
3
FWCI
1.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.