The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images
Abstract
A method was developed for registering three-dimensional knee implant models to single plane X-ray fluoroscopy images. We use a direct image-to-image similarity measure, taking advantage of the speed of modern computer graphics workstations to quickly render simulated (predicted) images. As a result, the method does not require an accurate segmentation of the implant silhouette in the image (which can be prone to errors). A robust optimization algorithm (simulated annealing) is used that can escape local minima and find the global minimum (true solution). Although we focus on the analysis of total knee arthroplasty (TKA) in this paper, the method can be (and has been) applied to other implanted joints, including, but not limited to, hips, ankles, and temporomandibular joints. Convergence tests on an in vivo image show that the registration method can reliably find poses that are very close to the optimal (i.e., within 0.4 degrees and 0.1 mm), even from starting poses with large initial errors. However, the precision of translation measurement in the Z (out-of-plane) direction is not as good. We also show that the method is robust with respect to image noise and occlusions. However, a small amount of user supervision and intervention is necessary to detect cases when the optimization algorithm falls into a local minimum. Intervention is required less than 5% of the time when the initial starting pose is reasonably close to the correct answer, but up to 50% of the time when the initial starting pose is far away. Finally, extensive evaluations were performed on cadaver images to determine accuracy of relative pose measurement. Comparing against data derived from an optical sensor as a "gold standard," the overall root-mean-square error of the registration method was approximately 1.5 degrees and 0.65 mm (although Z translation error was higher). However, uncertainty in the optical sensor data may account for a large part of the observed error.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimization by Simulated Annealing
Kirkpatrick, S., Gelatt, C. D., & Vecchi, M. P. (1983) · Science · doi:10.1126/science.220.4598.671 · Cited by 45,134
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Robust Regression and Outlier Detection
Piepel, G. F. (1989) · Technometrics · doi:10.1080/00401706.1989.10488524 · Cited by 6,144
Robust Regression and Outlier Detection
Rousseeuw, P. J., & Leroy, A. M. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/0471725382 · Cited by 5,609
Introduction to Robotics mechanics and Control
Craig, J. (1986) · Cited by 5,024
Wiley Series in Probability and Statistics
(2008) · Wiley series in probability and statistics · doi:10.1002/series1345 · Cited by 4,217
Closed-form solution of absolute orientation using unit quaternions
Horn, B. K. P. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000629 · Cited by 4,116
Haralock, R. M., & Shapiro, L. G. (1991) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 3,933
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
Telerobotics, Automation, and Human Supervisory Control
Sheridan, T. B. (1992) · Medical Entomology and Zoology · Cited by 1,949
McKerrow, P. J. (1991) · Medical Entomology and Zoology · Cited by 1,731
Introduction to robotics: Mechanics and control
Rodd, M. G. (1987) · Automatica · doi:10.1016/0005-1098(87)90105-1 · Cited by 1,505
Brownrigg, D. R. K. (1992) · Computer Physics Communications · doi:10.1016/0010-4655(92)90019-u · Cited by 920
Fitting parameterized three-dimensional models to images
Lowe, D. G. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.134043 · Cited by 837
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821189 · Cited by 736
Three-dimensional kinematics of the human knee during walking
Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., & Kalenak, A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90254-x · Cited by 694
Alignment by Maximization of Mutual Information
Viola, P. A. (1995) · doi:10.21236/ada299525 · Cited by 614
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
Banks, S. A., & Hodge, W. A. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.495283 · Cited by 596
Trucco, E. (1995) · AI Communications · doi:10.3233/aic-1995-8111 · Cited by 472
Tibiofemoral movement 2: the loaded and unloaded living knee studied by MRI
Hill, P. F., Vedi, V., Williams, A., Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821196 · Cited by 393
The envelope of passive knee joint motion
Blankevoort, L., Huiskes, R., & de Lange, A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90280-1 · Cited by 376
Justification of triaxial goniometer for the measurement of joint rotation
Chao, E. Y. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90044-5 · Cited by 355
Lavallee, S., & Szeliski, R. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.385980 · Cited by 242
Lemieux, L., Jagoe, R., Fish, D. R., Kitchen, N. D., & Thomas, D. G. T. (1994) · Medical Physics · doi:10.1118/1.597276 · Cited by 222
Knee biomechanics and total knee replacement
Andriacchi, T. P., Stanwyck, T. S., & Galante, J. O. (1986) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(86)80033-x · Cited by 197
Automatic retinal image registration scheme using global optimization techniques
Matsopoulos, G. K., Mouravliansky, N. A., Delibasis, K. K., & Nikita, K. S. (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.748975 · Cited by 189
The cruciate ligaments in total knee arthroplasty
Stiehl, J. B., Komistek, R. D., Cloutier, J.-M., & Dennis, D. A. (2000) · The Journal of Arthroplasty · doi:10.1054/arth.2000.4638 · Cited by 182
Self-citationHoff, W. A., Komistek, R. D., Dennis, D. A., Gabriel, S. M., & Walker, S. A. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00009-6 · Cited by 178
Self-citationVoxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery
Weese, J., Penney, G. P., Desmedt, P., Buzug, T. M., Hill, D. L. G., & Hawkes, D. J. (1997) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.681173 · Cited by 164
3D–2D Projective Registration of Free-Form Curves and Surfaces
Feldmar, J., Ayache, N., & Betting, F. (1997) · Computer Vision and Image Understanding · doi:10.1006/cviu.1996.0499 · Cited by 155
Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot
Gueziec, A. P., Kazanzides, P., Williamson, B., & Taylor, R. H. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736023 · Cited by 147
Hierarchical estimation of a dense deformation field for 3-D robust registration
Pierre Hellier, J., Barillot, C., Mémin, É., & Pérez, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.925292 · Cited by 128
Kärrholm, J., Brandsson, S., & Freeman, M. A. R. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b8.10715 · Cited by 122
Genetic algorithms for a robust 3-D MR-CT registration
Rouet, J.-M., Jacq, J.-J., & Roux, C. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.845205 · Cited by 112
Analysis of head pose accuracy in augmented reality
Hoff, W., & Vincent, T. L. (2000) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/2945.895877 · Cited by 90
Self-citationAn interactive system for kinematic analysis of artificial joint implants.
Sarojak, M., Hoff, W., Komistek, R. D., & Dennis, D. A. (1999) · PubMed · Cited by 15
Self-citation
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Self-citationGap Balancing versus Measured Resection Technique for Total Knee Arthroplasty
Dennis, D. A., Komistek, R. D., Kim, R. H., & Sharma, A. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-1112-3 · Cited by 262
Self-citationFregly, B. J., Rahman, H. A., & Banks, S. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1933949 · Cited by 155
Metadata
- Authors
- Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2003-12
- Volume
- 22
- Issue
- 12
- Pages
- 1561-1574
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2099752932
- Cited by
- 305
- References
- 37
- FWCI
- 14.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.