The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
A common formalism for the Integral formulations of the forward EEG problem
Open accessAbstract
The forward electroencephalography (EEG) problem involves finding a potential V from the Poisson equation inverted Delta x (sigma inverted Delta V) f, in which f represents electrical sources in the brain, and sigma the conductivity of the head tissues. In the piecewise constant conductivity head model, this can be accomplished by the boundary element method (BEM) using a suitable integral formulation. Most previous work uses the same integral formulation, corresponding to a double-layer potential. In this paper we present a conceptual framework based on a well-known theorem (Theorem 1) that characterizes harmonic functions defined on the complement of a bounded smooth surface. This theorem says that such harmonic functions are completely defined by their values and those of their normal derivatives on this surface. It allows us to cast the previous BEM approaches in a unified setting and to develop two new approaches corresponding to different ways of exploiting the same theorem. Specifically, we first present a dual approach which involves a single-layer potential. Then, we propose a symmetric formulation, which combines single- and double-layer potentials, and which is new to the field of EEG, although it has been applied to other problems in electromagnetism. The three methods have been evaluated numerically using a spherical geometry with known analytical solution, and the symmetric formulation achieves a significantly higher accuracy than the alternative methods. Additionally, we present results with realistically shaped meshes. Beside providing a better understanding of the foundations of BEM methods, our approach appears to lead also to more efficient algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Partial Differential Equations
(1988) · Lecture Notes in Mathematics · doi:10.1007/bfb0082920 · Cited by 23,383
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Partial Differential Equations
Evans, L. (2010) · Graduate Studies in Mathematics · doi:10.1090/gsm/019 · Cited by 3,648
Templates for the Solution of Linear Systems: Building Blocks for Iterative Methods
Barrett, R., Berry, M., Chan, T. F., Demmel, J., Donato, J., Dongarra, J., Eijkhout, V., Pozo, R., Romine, C., & van der Vorst, H. (1994) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971538 · Cited by 3,479
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Mathematical Analysis and Numerical Methods for Science and Technology
(2000) · Springer eBooks · doi:10.1007/978-3-642-58090-1 · Cited by 1,517
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989 · cited 2×
“The problem has largely been disregarded, or sometimes avoided at the expense of excessively simplifying the model: some authors propose to omit either the outer cortex boundary, or the skull, claiming that these simplifications are inconsequential for the localization accuracy [13, 14].”
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839
A precorrected-FFT method for electrostatic analysis of complicated 3-D structures
Phillips, J. R., & White, J. K. (1997) · IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems · doi:10.1109/43.662670 · Cited by 722
Mathematical Analysis and Numerical Methods for Science and Technology
(2000) · Springer eBooks · doi:10.1007/978-3-642-61566-5 · Cited by 445
Cited by
MNE software for processing MEG and EEG data
Gramfort, A., Luessi, M., Larson, E., Engemann, D. A., Strohmeier, D., Brodbeck, C., Parkkonen, L., & Hämäläinen, M. S. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.027 · Cited by 1,951
OpenMEEG: opensource software for quasistatic bioelectromagnetics
Gramfort, A., Papadopoulo, T., Olivi, E., & Clerc, M. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-45 · Cited by 1,154
Self-citationReview on solving the forward problem in EEG source analysis
Hallez, H., Vanrumste, B., Grech, R., Muscat, J., De Clercq, W., Vergult, A., D'Asseler, Y., Camilleri, K. P., Fabri, S. G., Van Huffel, S., et al. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-46 · Cited by 527
Spatial and temporal resolutions of EEG: Is it really black and white? A scalp current density view
Burle, B., Spieser, L., Roger, C., Casini, L., Hasbroucq, T., & Vidal, F. (2015) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2015.05.004 · Cited by 414
“The head model used here was based on a segmentation of the MNI152 template brain and the lead fi eld and forward solution were computed with the OpenMEEG software (Gramfort et al., 2010; Kybic et al., 2005), which is based on a symmetric Boundary Element Method.”
MethodMeasuring MEG Closer to the Brain: Performance of on-Scalp Sensor Arrays
Iivanainen, J., Stenroos, M., & Parkkonen, L. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.048 · Cited by 296
“Thus, the field computation for normal-component-measuring OPMs could potentially be done with a LC BEM, which is computationally lighter than the more accurate solvers such as LG BEM or symmetric BEM (Kybic et al., 2005).”
Modeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268
The effect of epoch length on estimated EEG functional connectivity and brain network organisation
Fraschini, M., Demuru, M., Crobe, A., Marrosu, F., Stam, C. J., & Hillebrand, A. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036015 · Cited by 268
Time-frequency mixed-norm estimates: Sparse M/EEG imaging with non-stationary source activations
Gramfort, A., Strohmeier, D., Haueisen, J., Hämäläinen, M. S., & Kowalski, M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.051 · Cited by 234
“The computation of the gain matrix G , e.g., with a Boundary Element Method (BEM) [24, 16], requires modeling of the electromagnetic properties of the head [19] such as the specification of the tissue conductivities.”
Differences in unity: The go/no-go and stop signal tasks rely on different mechanisms
Raud, L., Westerhausen, R., Dooley, N., & Huster, R. J. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116582 · Cited by 199
“13 brain = 1; Gramfort et al., 2010; Kybic et al., 2005).”
Hill, A. T., Rogasch, N. C., Fitzgerald, P. B., & Hoy, K. E. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.001 · Cited by 105
Heartbeat and somatosensory perception
Al, E., Iliopoulos, F., Nikulin, V. V., & Villringer, A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118247 · Cited by 86
Baird, B., Castelnovo, A., Riedner, B. A., Lutz, A., Ferrarelli, F., Boly, M., Davidson, R. J., & Tononi, G. (2018) · eneuro · doi:10.1523/eneuro.0293-18.2018 · Cited by 45
“A symmetric boundary element model (BEM) of the head having three realistic layers (scalp, inner skull, outer skull; Kybic et al., 2005; Gramfort et al., 2010) and a standard coregistered set of electrode positions were used to construct the forward model.”
Method
Metadata
- Authors
- Kybic, J., Clerc, M., Abboud, T., Faugeras, O., Keriven, R., & Papadopoulo, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-01
- Volume
- 24
- Issue
- 1
- Pages
- 12-28
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2150469050
- Cited by
- 422
- References
- 27
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.