Interplay between intensity standardization and inhomogeneity correction in MR image processing
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Image intensity standardization is a postprocessing method designed for correcting acquisition-to-acquisition signal intensity variations (nonstandardness) inherent in magnetic resonance (MR) images. Inhomogeneity correction is a process used to suppress the low frequency background nonuniformities (inhomogeneities) of the image domain that exist in MR images. Both these procedures have important implications in MR image analysis. The effects of these postprocessing operations on improvement of image quality in isolation has been well documented. However, the combined effects of these two processes on MR images and how the processes influence each other have not been studied thus far. In this paper, we evaluate the effect of inhomogeneity correction followed by standardization and vice-versa on MR images in order to determine the best sequence to follow for enhancing image quality. We conducted experiments on several clinical and phantom data sets (nearly 4000 three-dimensional MR images were analyzed) corresponding to four different MRI protocols. Different levels of artificial nonstandardness, and different models and levels of artificial background inhomogeneity were used in these experiments. Our results indicate that improved standardization can be achieved by preceding it with inhomogeneity correction. There is no statistically significant difference in image quality obtained between the results of standardization followed by correction and that of correction followed by standardization from the perspective of inhomogeneity correction. The correction operation is found to bias the effect of standardization. We demonstrate this bias both qualitatively and quantitatively by using two different methods of inhomogeneity correction. We also show that this bias in standardization is independent of the specific inhomogeneity correction method used. The effect of this bias due to correction was also seen in magnetization transfer ratio (MTR) images, which are naturally endowed with the standardness property. Standardization, on the other hand, does not seem to influence the correction operation. It is also found that longer sequences of repeated correction and standardization operations do not considerably improve image quality. These results were found to hold for the clinical and the phantom data sets, for different MRI protocols, for different levels of artificial nonstandardness, for different models and levels of artificial inhomogeneity, for different correction methods, and for images that were endowed with inherent standardness as well as for those that were standardized by using the intensity standardization method. Overall, we conclude that inhomogeneity correction followed by intensity standardization is the best sequence to follow from the perspective of both image quality and computational efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 2×
“The most popular choice of measure, however, seems to be the percent coefficient of variation ( ) [10], [11], [14] within tissue regions, defined by”
BackgroundAutomated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583
Cited by
Wen, J., Thibeau-Sutre, E., Diaz-Melo, M., Samper-González, J., Routier, A., Bottani, S., Dormont, D., Durrleman, S., Burgos, N., & Colliot, O. (2020) · Medical Image Analysis · doi:10.1016/j.media.2020.101694 · Cited by 809
State of the art survey on MRI brain tumor segmentation
Gordillo, N., Montseny, E., & Sobrevilla, P. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.05.002 · Cited by 697
“Reviews of these methods can be found in [31 – 33].”
MethodA Review on MR Image Intensity Inhomogeneity Correction
Hou, Z. (2006) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/2006/49515 · Cited by 200
“Madabhushi and Udupa [95] investigated the interplay between IIH correction and intensity standardization, and concluded that the better sequence is IIH correction followed by intensity standardization.”
BackgroundAutomated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI
Madabhushi, A., Feldman, M. D., Metaxas, D. N., Tomaszeweski, J., & Chute, D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.859208 · Cited by 184
“Image intensity variations due to radio frequency (RF) field inhomogeneities may be caused due to a number of different factors, including poor RF coil uniformity, static field inhomogeneity, and RF penetration [29]–[31].”
BackgroundSelf-citationEvaluating intensity normalization on MRIs of human brain with multiple sclerosis
Shah, M., Xiao, Y., Subbanna, N., Francis, S., Arnold, D. L., Collins, D. L., & Arbel, T. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.12.003 · Cited by 178
“Madabhushi and Udupa (2005), have investigated the image quality after interplay between the intensity normalization and inhomogeneity correction procedures.”
BackgroundMoradmand, H., Aghamiri, S. M. R., & Ghaderi, R. (2020) · Journal of Applied Clinical Medical Physics · doi:10.1002/acm2.12795 · Cited by 173
Altered Reward Circuitry in the Norepinephrine Transporter Knockout Mouse
Gallagher, J. J., Zhang, X., Hall, F. S., Uhl, G. R., Bearer, E. L., & Jacobs, R. E. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057597 · Cited by 25
“Briefly, images were stripped of non-brain material [104], corrected for B1 field inhomogeneities and each scaled to the mode of its intensity histogram [68,105,106].”
Method
Metadata
- Authors
- Madabhushi, A., & Udupa, J. K.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-05
- Volume
- 24
- Issue
- 5
- Pages
- 561-576
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2134139970
- Cited by
- 115
- References
- 3
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.