The DOI matches its Crossref record.
Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity
Abstract
Hemodynamic factors are thought to be implicated in the progression and rupture of intracranial aneurysms. Current efforts aim to study the possible associations of hemodynamic characteristics such as complexity and stability of intra-aneurysmal flow patterns, size and location of the region of flow impingement with the clinical history of aneurysmal rupture. However, there are no reliable methods for measuring blood flow patterns in vivo. In this paper, an efficient methodology for patient-specific modeling and characterization of the hemodynamics in cerebral aneurysms from medical images is described. A sensitivity analysis of the hemodynamic characteristics with respect to variations of several variables over the expected physiologic range of conditions is also presented. This sensitivity analysis shows that although changes in the velocity fields can be observed, the characterization of the intra-aneurysmal flow patterns is not altered when the mean input flow, the flow division, the viscosity model, or mesh resolution are changed. It was also found that the variable that has the greater impact on the computed flow fields is the geometry of the vascular structures. We conclude that with the proposed modeling pipeline clinical studies involving large numbers cerebral aneurysms are feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hemodynamics of Cerebral Aneurysms
Sforza, D. M., Putman, C. M., & Cebral, J. R. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102126 · Cited by 466
Self-citationA Framework for Geometric Analysis of Vascular Structures: Application to Cerebral Aneurysms
Piccinelli, M., Veneziani, A., Steinman, D. A., Remuzzi, A., & Antiga, L. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021652 · Cited by 346
Valen-Sendstad, K., Bergersen, A. W., Shimogonya, Y., Goubergrits, L., Bruening, J., Pallares, J., Cito, S., Piskin, S., Pekkan, K., Geers, A. J., et al. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-00374-2 · Cited by 128
Sarrami-Foroushani, A., Lassila, T., MacRaild, M., Asquith, J., Roes, K. C. B., Byrne, J. V., & Frangi, A. F. (2021) · Nature Communications · doi:10.1038/s41467-021-23998-w · Cited by 83
Self-citationFabrication of multilayered vascular tissues using microfluidic agarose hydrogel platforms
Kinoshita, K., Iwase, M., Yamada, M., Yajima, Y., & Seki, M. (2016) · Biotechnology Journal · doi:10.1002/biot.201600083 · Cited by 46
Metadata
- Authors
- Cebral, J. R., Castro, M. A., Appanaboyina, S., Putman, C. M., Millan, D., & Frangi, A. F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-04
- Volume
- 24
- Issue
- 4
- Pages
- 457-467
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2121710705
- Cited by
- 545
- References
- 0
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity. https://app.cochat.ai/papers/10.1109/tmi.2005.844159
- The paper
- Cebral, J. R., Castro, M. A., Appanaboyina, S., Putman, C. M., Millan, D., & Frangi, A. F. (2005). Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.844159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.