The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: technique and sensitivity
Abstract
Hemodynamic factors are thought to be implicated in the progression and rupture of intracranial aneurysms. Current efforts aim to study the possible associations of hemodynamic characteristics such as complexity and stability of intra-aneurysmal flow patterns, size and location of the region of flow impingement with the clinical history of aneurysmal rupture. However, there are no reliable methods for measuring blood flow patterns in vivo. In this paper, an efficient methodology for patient-specific modeling and characterization of the hemodynamics in cerebral aneurysms from medical images is described. A sensitivity analysis of the hemodynamic characteristics with respect to variations of several variables over the expected physiologic range of conditions is also presented. This sensitivity analysis shows that although changes in the velocity fields can be observed, the characterization of the intra-aneurysmal flow patterns is not altered when the mean input flow, the flow division, the viscosity model, or mesh resolution are changed. It was also found that the variable that has the greater impact on the computed flow fields is the geometry of the vascular structures. We conclude that with the proposed modeling pipeline clinical studies involving large numbers cerebral aneurysms are feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iterative Methods for Sparse Linear Systems
Saad, Y. (2003) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898718003 · Cited by 13,790
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
Self-citationSethian, J. A. (1999) · Cited by 3,622
A signal processing approach to fair surface design
Taubin, G. (1995) · Proceedings of the 22nd annual conference on Computer graphics and interactive techniques - SIGGRAPH '95 · doi:10.1145/218380.218473 · Cited by 1,855
Case-Fatality Rates and Functional Outcome After Subarachnoid Hemorrhage: A Systematic Review
Hop, J. W., Rinkel, G. J. E., Algra, A., & van Gijn, J. (1997) · Stroke · doi:10.1161/01.str.28.3.660 · Cited by 1,093
Linn, F. H. H., Rinkel, G. J. E., Algra, A., & van Gijn, J. (1996) · Stroke · doi:10.1161/01.str.27.4.625 · Cited by 634
Mortality and Morbidity of Surgery for Unruptured Intracranial Aneurysms: A Meta-Analysis
Raaymakers, T. W. M., Rinkel, G. J. E., Limburg, M., & Algra, A. (1998) · Stroke · doi:10.1161/01.str.29.8.1531 · Cited by 512
Image-based computational simulation of flow dynamics in a giant intracranial aneurysm.
Steinman, D. A., Milner, J. S., Norley, C. J. D., Lownie, S. P., & Holdsworth, D. W. (2003) · PubMed · Cited by 468
The Probability of Sudden Death from Rupture of Intracranial Aneurysms: A Meta-analysis
Huang, J., & van Gelder, J. M. (2002) · Neurosurgery · doi:10.1097/00006123-200211000-00001 · Cited by 321
Cerebral aneurysms and variations in the circle of Willis.
Kayembe, K. N., Sasahara, M., & Hazama, F. (1984) · Stroke · doi:10.1161/01.str.15.5.846 · Cited by 304
Cited by
An image-based modeling framework for patient-specific computational hemodynamics
Antiga, L., Piccinelli, M., Botti, L., Ene-Iordache, B., Remuzzi, A., & Steinman, D. A. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0420-1 · Cited by 850
MORPHOLOGY PARAMETERS FOR INTRACRANIAL ANEURYSM RUPTURE RISK ASSESSMENT
Dhar, S., Tremmel, M., Mocco, J., Kim, M., Yamamoto, J., Siddiqui, A. H., Hopkins, L. N., & Meng, H. (2008) · Neurosurgery · doi:10.1227/01.neu.0000316847.64140.81 · Cited by 589
Cebral, J. R., Mut, F., Weir, J., & Putman, C. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2419 · Cited by 470
Self-citationAssociation of Hemodynamic Characteristics and Cerebral Aneurysm Rupture
Cebral, J. R., Mut, F., Weir, J., & Putman, C. M. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2274 · Cited by 467
Self-citationHemodynamics of Cerebral Aneurysms
Sforza, D. M., Putman, C. M., & Cebral, J. R. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102126 · Cited by 466
Self-citationPatient-Specific Modeling of Cardiovascular Mechanics
Taylor, C. A., & Figueroa, C. A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160521 · Cited by 451
Cebral, J. R., Mut, F., Raschi, M., Scrivano, E., Ceratto, R., Lylyk, P., & Putman, C. M. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2398 · Cited by 390
Self-citationA Framework for Geometric Analysis of Vascular Structures: Application to Cerebral Aneurysms
Piccinelli, M., Veneziani, A., Steinman, D. A., Remuzzi, A., & Antiga, L. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021652 · Cited by 346
Taylor, C. A., & Steinman, D. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9901-0 · Cited by 261
Valen-Sendstad, K., Bergersen, A. W., Shimogonya, Y., Goubergrits, L., Bruening, J., Pallares, J., Cito, S., Piskin, S., Pekkan, K., Geers, A. J., et al. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-00374-2 · Cited by 128
Sarrami-Foroushani, A., Lassila, T., MacRaild, M., Asquith, J., Roes, K. C. B., Byrne, J. V., & Frangi, A. F. (2021) · Nature Communications · doi:10.1038/s41467-021-23998-w · Cited by 83
Self-citationFabrication of multilayered vascular tissues using microfluidic agarose hydrogel platforms
Kinoshita, K., Iwase, M., Yamada, M., Yajima, Y., & Seki, M. (2016) · Biotechnology Journal · doi:10.1002/biot.201600083 · Cited by 46
Gao, H., Zhu, X., & Wang, J.-X. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2020.113047 · Cited by 27
“There are numerous literature on examining the influence of variations in inflow/outflow boundary conditions [6–18], segmented vascular geometry [19–28], and mechanical properties of blood flow or vessel walls [29–33] on the simulated hemodynamics.”
Background
Metadata
- Authors
- Cebral, J. R., Castro, M. A., Appanaboyina, S., Putman, C. M., Millan, D., & Frangi, A. F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-04
- Volume
- 24
- Issue
- 4
- Pages
- 457-467
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2121710705
- Cited by
- 545
- References
- 15
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.