The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Toward automated segmentation of the pathological lung in CT
Abstract
Conventional methods of lung segmentation rely on a large gray value contrast between lung fields and surrounding tissues. These methods fail on scans with lungs that contain dense pathologies, and such scans occur frequently in clinical practice. We propose a segmentation-by-registration scheme in which a scan with normal lungs is elastically registered to a scan containing pathology. When the resulting transformation is applied to a mask of the normal lungs, a segmentation is found for the pathological lungs. As a mask of the normal lungs, a probabilistic segmentation built up out of the segmentations of 15 registered normal scans is used. To refine the segmentation, voxel classification is applied to a certain volume around the borders of the transformed probabilistic mask. Performance of this scheme is compared to that of three other algorithms: a conventional, a user-interactive and a voxel classification method. The algorithms are tested on 10 three-dimensional thin-slice computed tomography volumes containing high-density pathology. The resulting segmentations are evaluated by comparing them to manual segmentations in terms of volumetric overlap and border positioning measures. The conventional and user-interactive methods that start off with thresholding techniques fail to segment the pathologies and are outperformed by both voxel classification and the refined segmentation-by-registration. The refined registration scheme enjoys the additional benefit that it does not require pathological (hand-segmented) training data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
Hofmanninger, J., Prayer, F., Pan, J., Röhrich, S., Prosch, H., & Langs, G. (2020) · European Radiology Experimental · doi:10.1186/s41747-020-00173-2 · Cited by 595
Combination Strategies in Multi-Atlas Image Segmentation: Application to Brain MR Data
Artaechevarria, X., Munoz-Barrutia, A., & Ortiz-de-Solorzano, C. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2014372 · Cited by 507
Klein, S., Staring, M., & Pluim, J. P. W. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909412 · Cited by 431
Adaptive Stochastic Gradient Descent Optimisation for Image Registration
Klein, S., Pluim, J. P. W., Staring, M., & Viergever, M. A. (2009) · International Journal of Computer Vision · doi:10.1007/s11263-008-0168-y · Cited by 387
Isgum, I., Staring, M., Rutten, A., Prokop, M., Viergever, M. A., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2011480 · Cited by 361
Self-citation
Metadata
- Authors
- Sluimer, I., Prokop, M., & van Ginneken, B.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2005-08
- Volume
- 24
- Issue
- 8
- Pages
- 1025-1038
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2161912327
- Cited by
- 237
- References
- 1
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward automated segmentation of the pathological lung in CT. https://app.cochat.ai/papers/10.1109/tmi.2005.851757
- The paper
- Sluimer, I., Prokop, M., & van Ginneken, B. (2005). Toward automated segmentation of the pathological lung in CT. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2005.851757
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.