Four-Chamber Heart Modeling and Automatic Segmentation for 3-D Cardiac CT Volumes Using Marginal Space Learning and Steerable Features
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
We propose an automatic four-chamber heart segmentation system for the quantitative functional analysis of the heart from cardiac computed tomography (CT) volumes. Two topics are discussed: heart modeling and automatic model fitting to an unseen volume. Heart modeling is a nontrivial task since the heart is a complex nonrigid organ. The model must be anatomically accurate, allow manual editing, and provide sufficient information to guide automatic detection and segmentation. Unlike previous work, we explicitly represent important landmarks (such as the valves and the ventricular septum cusps) among the control points of the model. The control points can be detected reliably to guide the automatic model fitting process. Using this model, we develop an efficient and robust approach for automatic heart chamber segmentation in 3-D CT volumes. We formulate the segmentation as a two-step learning problem: anatomical structure localization and boundary delineation. In both steps, we exploit the recent advances in learning discriminative models. A novel algorithm, marginal space learning (MSL), is introduced to solve the 9-D similarity transformation search problem for localizing the heart chambers. After determining the pose of the heart chambers, we estimate the 3-D shape through learning-based boundary delineation. The proposed method has been extensively tested on the largest dataset (with 323 volumes from 137 patients) ever reported in the literature. To the best of our knowledge, our system is the fastest with a speed of 4.0 s per volume (on a dual-core 3.2-GHz processor) for the automatic segmentation of all four chambers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid object detection using a boosted cascade of simple features
Viola, P., & Jones, M. (2005) · Proceedings of the 2001 IEEE Computer Society Conference on Computer Vision and Pattern Recognition. CVPR 2001 · doi:10.1109/cvpr.2001.990517 · Cited by 18,300
Active Shape Models-Their Training and Application
Cootes, T. F., Taylor, C. J., Cooper, D. H., & Graham, J. (1995) · Computer Vision and Image Understanding · doi:10.1006/cviu.1995.1004 · Cited by 7,190
Cootes, T. F., Edwards, G. J., & Taylor, C. J. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.927467 · Cited by 5,409
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
Improved boosting algorithms using confidence-rated predictions
Schapire, R. E., & Singer, Y. (1998) · Proceedings of the eleventh annual conference on Computational learning theory · doi:10.1145/279943.279960 · Cited by 2,547
Learning to detect natural image boundaries using local brightness, color, and texture cues
Martin, D. R., Fowlkes, C. C., & Malik, J. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.1273918 · Cited by 2,420
Improved Boosting Algorithms Using Confidence-rated Predictions
Schapire, R. E., & Singer, Y. (1999) · Machine Learning · doi:10.1023/a:1007614523901 · Cited by 1,971
Pedestrian detection using wavelet templates
Oren, M., Papageorgiou, C., Sinha, P., Osuna, E., & Poggio, T. (2002) · Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1997.609319 · Cited by 695
A minimum description length approach to statistical shape modeling
Davies, R. H., Twining, C. J., Cootes, T. F., Waterton, J. C., & Taylor, C. J. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.1009388 · Cited by 572
Three-dimensional modeling for functional analysis of cardiac images, a review
Frangi, A. F., Niessen, W. J., & Viergever, M. A. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906421 · Cited by 533
Research works printed but not linked: 11
- 10.1007/s11263-006-7936-3 · doi:10.1007/s11263-006-7936-3
- 10.1109/6104.956807 · DOI
- neubauer, 2003, analysis of four-dimensional cardiac data sets using skeleton-based segmentation, Proc Int Conf Central Eur Comput Graphics Visualizat
- zheng, 2008, four-chamber heart modeling and automatic segmentation for 3-d cardiac ct volumes, Proc SPIE Med Imag, 10.1109/TMI.2008.2004421
- ecabert, 2006, modeling shape variability for full heart segmentation in cardiac computed-tomography images, Proc SPIE Med Imag, 1199
- 10.1006/cviu.1999.0814 · doi:10.1006/cviu.1999.0814
- fritz, 2005, automatic segmentation of the left ventricle and computation of diagnostic parameters using regiongrowing and a statistical model, Proc SPIE Med Imag, 1844, 10.1117/12.595071 · doi:10.1117/12.595071
- 10.3949/ccjm.72.2.127 · doi:10.3949/ccjm.72.2.127
- lu, 2008, automatic detection of standard planes from three dimensional echocardiographic data, Proc 1st IEEE Int Symp Biomed Imag, 1279
- 10.1145/1042091.1042118 · doi:10.1145/1042091.1042118
- 10.1109/TMI.2002.804435 · DOI
Cited by
Deep Learning for Cardiac Image Segmentation: A Review
Chen, C., Qin, C., Qiu, H., Tarroni, G., Duan, J., Bai, W., & Rueckert, D. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00025 · Cited by 869
Deep Learning in Medical Ultrasound Analysis: A Review
Liu, S., Wang, Y., Yang, X., Lei, B., Liu, L., Li, S. X., Ni, D., & Wang, T. (2019) · Engineering · doi:10.1016/j.eng.2018.11.020 · Cited by 798
Artificial Intelligence in Cardiovascular Imaging
Dey, D., Slomka, P. J., Leeson, P., Comaniciu, D., Shrestha, S., Sengupta, P. P., & Marwick, T. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.054 · Cited by 680
Self-citation3D deeply supervised network for automated segmentation of volumetric medical images
Dou, Q., Yu, L., Chen, H., Jin, Y., Yang, X., Qin, J., & Heng, P.-A. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.05.001 · Cited by 613
Multi-scale patch and multi-modality atlases for whole heart segmentation of MRI
Zhuang, X., & Shen, J. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.02.006 · Cited by 502
Liang, L., Liu, M., Martin, C., & Sun, W. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0844 · Cited by 502
Itu, L., Rapaka, S., Passerini, T., Georgescu, B., Schwemmer, C., Schoebinger, M., Flohr, T., Sharma, P., & Comaniciu, D. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00752.2015 · Cited by 406
Self-citationState-of-the-Art Deep Learning in Cardiovascular Image Analysis
Litjens, G., Ciompi, F., Wolterink, J. M., de Vos, B. D., Leiner, T., Teuwen, J., & Išgum, I. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2019.06.009 · Cited by 388
Ngo, T. A., Lu, Z., & Carneiro, G. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.05.009 · Cited by 332
Roth, H. R., Lu, L., Lay, N., Harrison, A. P., Farag, A., Sohn, A., & Summers, R. M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.01.006 · Cited by 325
Artificial intelligence and machine learning in spine research
Galbusera, F., Casaroli, G., & Bassani, T. (2019) · JOR SPINE · doi:10.1002/jsp2.1044 · Cited by 317
Multi-Scale Deep Reinforcement Learning for Real-Time 3D-Landmark Detection in CT Scans
Ghesu, F.-C., Georgescu, B., Zheng, Y., Grbic, S., Maier, A., Hornegger, J., & Comaniciu, D. (2019) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2782687 · Cited by 310
Self-citationTowards robust and effective shape modeling: Sparse shape composition
Zhang, S., Zhan, Y., Dewan, M., Huang, J., Metaxas, D. N., & Zhou, X. S. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.08.004 · Cited by 249
Constrained deep weak supervision for histopathology image segmentation
Jia, Z., Huang, X., Chang, E. I.-C., & Xu, Y. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2724070 · Cited by 242
Sermesant, M., Chabiniok, R., Chinchapatnam, P., Mansi, T., Billet, F., Moireau, P., Peyrat, J. M., Wong, K., Relan, J., Rhode, K., et al. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.07.003 · Cited by 232
Zreik, M., Lessmann, N., van Hamersvelt, R. W., Wolterink, J. M., Voskuil, M., Viergever, M. A., Leiner, T., & Išgum, I. (2018) · Medical Image Analysis · doi:10.1016/j.media.2017.11.008 · Cited by 216
Carneiro, G., Nascimento, J. C., & Freitas, A. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2169273 · Cited by 208
Benchmark for Algorithms Segmenting the Left Atrium From 3D CT and MRI Datasets
Tobon-Gomez, C., Geers, A. J., Peters, J., Weese, J., Pinto, K., Karim, R., Ammar, M., Daoudi, A., Margeta, J., Sandoval, Z., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2398818 · Cited by 203
Self-citationIonasec, R. I., Voigt, I., Georgescu, B., Wang, Y., Houle, H., Vega-Higuera, F., Navab, N., & Comaniciu, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2048756 · Cited by 194
Self-citationFarag, A., Lu, L., Roth, H. R., Liu, J., Turkbey, E., & Summers, R. M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2016.2624198 · Cited by 185
Benchmarking framework for myocardial tracking and deformation algorithms: An open access database
Tobon-Gomez, C., De Craene, M., McLeod, K., Tautz, L., Shi, W., Hennemuth, A., Prakosa, A., Wang, H., Carr-White, G., Kapetanakis, S., et al. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.03.008 · Cited by 171
4-D Cardiac MR Image Analysis: Left and Right Ventricular Morphology and Function
Zhang, H., Wahle, A., Johnson, R. K., Scholz, T. D., & Sonka, M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2030799 · Cited by 165
Challenges and Methodologies of Fully Automatic Whole Heart Segmentation: A Review
Zhuang, X. (2013) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.4.3.371 · Cited by 162
Efficient Multiple Organ Localization in CT Image Using 3D Region Proposal Network
Xu, X., Zhou, F., Liu, B., Fu, D., & Bai, X. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2894854 · Cited by 144
Marginal space deep learning: efficient architecture for volumetric image parsing
Ghesu, F. C., Krubasik, E., Georgescu, B., Singh, V., Zheng, Y., Hornegger, J., & Comaniciu, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2538802 · Cited by 142
Strocchi, M., Augustin, C. M., Gsell, M. A. F., Karabelas, E., Neic, A., Gillette, K., Razeghi, O., Prassl, A. J., Vigmond, E. J., Behar, J. M., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235145 · Cited by 112
Training an Active Random Field for Real-Time Image Denoising
Barbu, A. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028254 · Cited by 105
Self-citationEvaluating Segmentation Error without Ground Truth
Kohlberger, T., Singh, V., Alvino, C., Bahlmann, C., & Grady, L. (2012) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-33415-3_65 · Cited by 102
Automatic Detection and Segmentation of Lymph Nodes From CT Data
Barbu, A., Suehling, M., Xu, X., Liu, D., Zhou, S. K., & Comaniciu, D. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2168234 · Cited by 94
Self-citationXu, L., Liu, M., Shen, Z., Wang, H., Liu, X., Wang, X., Wang, S., Li, T., Yu, S., Hou, M., et al. (2020) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2019.101690 · Cited by 87
Artificial Intelligence in Cardiovascular Medicine
Seetharam, K., Shrestha, S., & Sengupta, P. P. (2019) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-019-0728-1 · Cited by 76
Image-Based Predictive Modeling of Heart Mechanics
Wang, V. Y., Nielsen, P. M. F., & Nash, M. P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040609 · Cited by 63
Learning to detect anatomical landmarks of the pelvis in X-rays from arbitrary views
Bier, B., Goldmann, F., Zaech, J.-N., Fotouhi, J., Hegeman, R., Grupp, R., Armand, M., Osgood, G., Navab, N., Maier, A., et al. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-01975-5 · Cited by 43
Deep learning on sparse manifolds for faster object segmentation
Nascimento, J. C., & Carneiro, G. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2725582 · Cited by 17
Median Filter Helps Lymph Node Segmentation in Deep Learning via PET/CT
Zhang, X., Liao, W., & Xu, G. (2021) · 2021 4th International Conference on Digital Medicine and Image Processing · doi:10.1145/3506651.3506662 · Cited by 1
Metadata
- Authors
- Zheng, Y., Barbu, A., Georgescu, B., Scheuering, M., & Comaniciu, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2008-11
- Volume
- 27
- Issue
- 11
- Pages
- 1668-1681
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2101689475
- Cited by
- 546
- References
- 34
- FWCI
- 46.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.