The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
An Active Contour Model for Segmenting and Measuring Retinal Vessels
Open accessAbstract
This paper presents an algorithm for segmenting and measuring retinal vessels, by growing a "Ribbon of Twins" active contour model, which uses two pairs of contours to capture each vessel edge, while maintaining width consistency. The algorithm is initialized using a generalized morphological order filter to identify approximate vessels centerlines. Once the vessel segments are identified the network topology is determined using an implicit neural cost function to resolve junction configurations. The algorithm is robust, and can accurately locate vessel edges under difficult conditions, including noisy blurred edges, closely parallel vessels, light reflex phenomena, and very fine vessels. It yields precise vessel width measurements, with subpixel average width errors. We compare the algorithm with several benchmarks from the literature, demonstrating higher segmentation sensitivity and more accurate width measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Comparative study of retinal vessel segmentation methods on a new publicly available database
Niemeijer, M., Staal, J., van Ginneken, B., Loog, M., & Abramoff, M. D. (2004) · SPIE Proceedings · doi:10.1117/12.535349 · Cited by 790
Jiang, X., & Mojon, D. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1159954 · Cited by 679
Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., Fletcher, E., & Kennedy, L. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.823261 · Cited by 389
Self-citationThe detection and quantification of retinopathy using digital angiograms
Zhou, L., Rzeszotarski, M. S., Singerman, L. J., & Chokreff, J. M. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363106 · Cited by 292
Measurement of Retinal Vessel Widths From Fundus Images Based on 2-D Modeling
Lowell, J., Hunter, A., Steel, D., Basu, A., Ryder, R., & Kennedy, R. L. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.830524 · Cited by 255
Self-citationRetinal blood vessel detection and tracking by matched Gaussian and Kalman filters
Chutatape, O., Zheng, L., & Krishnan, S. M. (2002) · Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286) · doi:10.1109/iembs.1998.746160 · Cited by 228
Automatic extraction of roads from aerial images based on scale space and snakes
Laptev, I., Mayer, H., Lindeberg, T., Eckstein, W., Steger, C. T., & Baumgartner, A. (1999) · Cited by 218
Hypertension and Retinopathy, Arteriolar Narrowing, and Arteriovenous Nicking in a Population
Klein, R. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090130102026 · Cited by 212
A robust snake implementation; a dual active contour
Gunn, S. R., & Nixon, M. S. (1997) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.566812 · Cited by 199
Automatic extraction of roads from aerial images based on scale space and snakes
Ivan Laptev, A., Mayer, H., Tony Lindeberg, C., Eckstein, W., Steger, C. T., & Baumgartner, A. (2000) · Machine Vision and Applications · doi:10.1007/s001380050121 · Cited by 199
(1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(99)80172-x · Cited by 166
Computer algorithms for the automated measurement of retinal arteriolar diameters
Chapman, N., Witt, N., Gao, X., Bharath, A. A., Stanton, A. V., Thom, S. A., & Hughes, A. D. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.1.74 · Cited by 123
Cited by
An Ensemble Classification-Based Approach Applied to Retinal Blood Vessel Segmentation
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2205687 · Cited by 1,031
Blood vessel segmentation methodologies in retinal images – A survey
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.03.009 · Cited by 1,001
Trainable COSFIRE filters for vessel delineation with application to retinal images
Azzopardi, G., Strisciuglio, N., Vento, M., & Petkov, N. (2015) · Medical Image Analysis · doi:10.1016/j.media.2014.08.002 · Cited by 713
A Cross-Modality Learning Approach for Vessel Segmentation in Retinal Images
Li, Q., Feng, B., Xie, L., Liang, P., Zhang, H., & Wang, T. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2457891 · Cited by 571
Orlando, J. I., Prokofyeva, E., & Blaschko, M. B. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2535311 · Cited by 503
Metadata
- Authors
- Al-Diri, B., Hunter, A., & Steel, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2009-09
- Volume
- 28
- Issue
- 9
- Pages
- 1488-1497
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2171459511
- Cited by
- 431
- References
- 17
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.