The DOI matches its Crossref record.
Model-Based Reconstruction for Magnetic Particle Imaging
Abstract
Magnetic particle imaging (MPI) is a new imaging modality capable of imaging distributions of superparamagnetic nanoparticles with high sensitivity, high spatial resolution and, in particular, high imaging speed. The image reconstruction process requires a system function, describing the mapping between particle distribution and acquired signal. To date, the system function is acquired in a tedious calibration procedure by sequentially measuring the signal of a delta sample at the positions of a grid that covers the field of view. In this work, for the first time, the system function is calculated using a model of the signal chain. The modeled system function allows for reconstruction of the particle distribution in a 1-D MPI experiment. The approach thus enables fast generation of system functions on arbitrarily dense grids. Furthermore, reduction in memory requirements may be feasible by generating parts of the system function on the fly during reconstruction instead of keeping the complete matrix in memory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
Self-citationMagnetic particle imaging with tailored iron oxide nanoparticle tracers
Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Arami, H., Saritas, E. U., Croft, L. R., Konkle, J., Goodwill, P. W., Halkola, A., Rahmer, J., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2375065 · Cited by 222
Self-citationPablico-Lansigan, M. H., Situ, S. F., & Samia, A. C. S. (2013) · Nanoscale · doi:10.1039/c3nr00544e · Cited by 172
Metadata
- Authors
- Knopp, T., Sattel, T. F., Biederer, S., Rahmer, J., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-01
- Volume
- 29
- Issue
- 1
- Pages
- 12-18
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2152046459
- Cited by
- 184
- References
- 0
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Model-Based Reconstruction for Magnetic Particle Imaging. https://app.cochat.ai/papers/10.1109/tmi.2009.2021612
- The paper
- Knopp, T., Sattel, T. F., Biederer, S., Rahmer, J., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M. (2010). Model-Based Reconstruction for Magnetic Particle Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2009.2021612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.