Nonrigid Image Registration Using Conditional Mutual Information
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Maximization of mutual information (MMI) is a popular similarity measure for medical image registration. Although its accuracy and robustness has been demonstrated for rigid body image registration, extending MMI to nonrigid image registration is not trivial and an active field of research. We propose conditional mutual information (cMI) as a new similarity measure for nonrigid image registration. cMI starts from a 3-D joint histogram incorporating, besides the intensity dimensions, also a spatial dimension expressing the location of the joint intensity pair. cMI is calculated as the expected value of the cMI between the image intensities given the spatial distribution. The cMI measure was incorporated in a tensor-product B-spline nonrigid registration method, using either a Parzen window or generalized partial volume kernel for histogram construction. cMI was compared to the classical global mutual information (gMI) approach in theoretical, phantom, and clinical settings. We show that cMI significantly outperforms gMI for all applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2001) · Wiley eBooks · doi:10.1002/0471200611 · Cited by 36,808
Elements of Information Theory
Cover, T. M., & Thomas, J. A. (2005) · doi:10.1002/047174882x · Cited by 13,791
A Limited Memory Algorithm for Bound Constrained Optimization
Byrd, R. H., Lu, P., Nocedal, J., & Zhu, C. (1995) · SIAM Journal on Scientific Computing · doi:10.1137/0916069 · Cited by 6,221
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 1×
“tensor-product B-spline registration algorithm [14], using the”
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“Each similarity measure is based upon the (conditional) joint histogram, which is estimated using either Parzen window (PW) interpolation [12] or generalized partial volume (PV) estimation [16], [17].”
MethodSelf-citationMutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Alignment by maximization of mutual information
Viola, P., & Wells, W. M. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466930 · Cited by 1,082
Comparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884
Self-citationOptimization of mutual information for multiresolution image registration
Unser, M., & Thevenaz, P. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.887976 · Cited by 697
Cited by
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
“…2007; Vercauteren et al., 2009), cross-correlation (Gee, 1999; Ardekani et al., 2005; Avants et al., 2008), and mutual information (Viola and Wells, 1997; Rueckert et al., 1999; D'Agostino et al., 2003; Crum et al., 2003; Rogelj and Kovacic, 2006; Tao et al., 2009; Loeckx et al., 2010).”
BackgroundDeformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“[349] proposed to condition the evaluation of MI upon the position.”
BackgroundMultimodal Data Fusion: An Overview of Methods, Challenges, and Prospects
Lahat, D., Adali, T., & Jutten, C. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2460697 · Cited by 1,296
“One approach uses information theory and maximizes mutual information [148], [149].”
BackgroundImage Matching from Handcrafted to Deep Features: A Survey
Ma, J., Jiang, X., Fan, A., Jiang, J., & Yan, J. (2021) · International Journal of Computer Vision · doi:10.1007/s11263-020-01359-2 · Cited by 990
Medical image registration: a review
Oliveira, F. P. M., & Tavares, J. M. R. S. (2014) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2012.670855 · Cited by 737
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Intensity-Based Image Registration by Minimizing Residual Complexity
Myronenko, A., & Song, X. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053043 · Cited by 325
MURF: Mutually Reinforcing Multi-Modal Image Registration and Fusion
Xu, H., Yuan, J., & Ma, J. (2023) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2023.3283682 · Cited by 288
Non-local Shape Descriptor: A New Similarity Metric for Deformable Multi-modal Registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, J. M., & Schnabel, J. A. (2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-23629-7_66 · Cited by 268
Esposito, A., Palmisano, A., Antunes, S., Maccabelli, G., Colantoni, C., Rancoita, P. M. V., Baratto, F., Di Serio, C., Rizzo, G., De Cobelli, F., et al. (2016) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2015.10.024 · Cited by 166
Fu, Y., Lei, Y., Wang, T., Patel, P., Jani, A. B., Mao, H., Curran, W. J., Liu, T., & Yang, X. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101845 · Cited by 75
“As a result, statistical image texture similarities such as mutual information (MI) are often used in multi-modality image registration (Heinrich et al., 2012; Loeckx et al., 2010).”
Method
Metadata
- Authors
- Loeckx, D., Slagmolen, P., Maes, F., Vandermeulen, D., & Suetens, P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-01
- Volume
- 29
- Issue
- 1
- Pages
- 19-29
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2143667750
- Cited by
- 257
- References
- 16
- FWCI
- 32.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.