The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Quantitative Analysis of Pulmonary Emphysema Using Local Binary Patterns
Abstract
We aim at improving quantitative measures of emphysema in computed tomography (CT) images of the lungs. Current standard measures, such as the relative area of emphysema (RA), rely on a single intensity threshold on individual pixels, thus ignoring any interrelations between pixels. Texture analysis allows for a much richer representation that also takes the local structure around pixels into account. This paper presents a texture classification-based system for emphysema quantification in CT images. Measures of emphysema severity are obtained by fusing pixel posterior probabilities output by a classifier. Local binary patterns (LBP) are used as texture features, and joint LBP and intensity histograms are used for characterizing regions of interest (ROIs). Classification is then performed using a k nearest neighbor classifier with a histogram dissimilarity measure as distance. A 95.2% classification accuracy was achieved on a set of 168 manually annotated ROIs, comprising the three classes: normal tissue, centrilobular emphysema, and paraseptal emphysema. The measured emphysema severity was in good agreement with a pulmonary function test (PFT) achieving correlation coefficients of up to |r| = 0.79 in 39 subjects. The results were compared to RA and to a Gaussian filter bank, and the texture-based measures correlated significantly better with PFT than did RA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Multiresolution gray-scale and rotation invariant texture classification with local binary patterns
Ojala, T., Pietikainen, M., & Maenpaa, T. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2002.1017623 · Cited by 15,398
A comparative study of texture measures with classification based on featured distributions
Ojala, T., Pietikäinen, M., & Harwood, D. (1996) · Pattern Recognition · doi:10.1016/0031-3203(95)00067-4 · Cited by 6,882
Statistical pattern recognition: a review
Jain, A. K., Duin, P. W., & Mao, J. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824819 · Cited by 6,767
Statistical and structural approaches to texture
Haralick, R. M. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11328 · Cited by 5,759
Swain, M. J., & Ballard, D. H. (1991) · International Journal of Computer Vision · doi:10.1007/bf00130487 · Cited by 5,623
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Kittler, J., Hatef, M., Duin, R. P. W., & Matas, J. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.667881 · Cited by 5,290
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925
Approximate Statistical Tests for Comparing Supervised Classification Learning Algorithms
Dietterich, T. G. (1998) · Neural Computation · doi:10.1162/089976698300017197 · Cited by 3,840
(1993) · PubMed · Cited by 3,827
Dynamic Texture Recognition Using Local Binary Patterns with an Application to Facial Expressions
Zhao, G., & Pietikainen, M. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1110 · Cited by 2,846
Tüceryan, M., & Jain, A. K. (1993) · Cited by 1,837
Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
Hu, S., Hoffman, E. A., & Reinhardt, J. M. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929615 · Cited by 940
Müller, N. L., Staples, C. A., Miller, R. R., & Abboud, R. T. (1988) · Chest · doi:10.1378/chest.94.4.782 · Cited by 798
Health status measurement in chronic obstructive pulmonary disease
Jones, P. W. (2001) · Thorax · doi:10.1136/thorax.56.11.880 · Cited by 557
High-Resolution CT of the Lung
Webb, W. R., Muller, N. L., Naidich, D. P., & Meziane, M. A. (1997) · Journal of Bronchology · doi:10.1097/00128594-199704000-00036 · Cited by 457
Kinsella, M., Müller, N. L., Abboud, R. T., Morrison, N. J., & DyBuncio, A. (1990) · Chest · doi:10.1378/chest.97.2.315 · Cited by 298
Handbook of Pattern Recognition and Computer Vision
(1999) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789812384737 · Cited by 290
Quantification of Pulmonary Emphysema from Lung Computed Tomography Images
UPPALURI, R., MITSA, T., SONKA, M., HOFFMAN, E. A., & McLENNAN, G. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.1.9606093 · Cited by 276
MDCT-based 3-D texture classification of emphysema and early smoking related lung pathologies
Xu, Y., Sonka, M., McLennan, G., Guo, J., & Hoffman, E. A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.870889 · Cited by 232
Computer Recognition of Regional Lung Disease Patterns
UPPALURI, R., HOFFMAN, E. A., SONKA, M., HARTLEY, P. G., HUNNINGHAKE, G. W., & McLENNAN, G. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.2.9804094 · Cited by 227
Dissimilarity representations allow for building good classifiers
Pękalska, E., & Duin, R. P. W. (2002) · Pattern Recognition Letters · doi:10.1016/s0167-8655(02)00024-7 · Cited by 219
Lung CT density correlates with measurements of airflow limitation and the diffusing capacity
Gould, G., Redpath, A., Ryan, M., Warren, P., Best, J., Flenley, D., & MacNee, W. (1991) · European Respiratory Journal · doi:10.1183/09031936.93.04020141 · Cited by 206
Computer‐aided diagnosis in high resolution CT of the lungs
Sluimer, I. C., van Waes, P. F. G. M., Viergever, M. A., & van Ginneken, B. (2003) · Medical Physics · doi:10.1118/1.1624771 · Cited by 134
False Positive Reduction in Mammographic Mass Detection Using Local Binary Patterns
Oliver, A., Lladó, X., Freixenet, J., & Martí, J. (2007) · Springer eBooks · doi:10.1007/978-3-540-75757-3_35 · Cited by 126
Classifier conditional posterior probabilities
Duin, R. P. W., & Tax, D. M. J. (1998) · Lecture notes in computer science · doi:10.1007/bfb0033285 · Cited by 84
Lung Tissue Classification Using Wavelet Frames
Depeursinge, A., Sage, D., Hidki, A., Platon, A., Poletti, P., Unser, M. A., & Müller, H. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353786 · Cited by 62
Sluimer, I. C., Prokop, M., Hartmann, I. J. C., & van Ginneken, B. (2006) · Medical Physics · doi:10.1118/1.2207131 · Cited by 60
ANALYZING CORRELATIONS BETWEEN STREAM AND WATERSHED ATTRIBUTES1
Sickle, J. V. V. (2003) · JAWRA Journal of the American Water Resources Association · doi:10.1111/j.1752-1688.2003.tb03687.x · Cited by 58
Texture Classification in Lung CT Using Local Binary Patterns
Sørensen, L., Shaker, S. B., & de Bruijne, M. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-85988-8_111 · Cited by 41
Self-citationStavngaard, T., Shaker, S. B., Bach, K., Stoel, B. C., & Dirksen, A. (2006) · Acta Radiologica · doi:10.1080/02841850600917170 · Cited by 36
Self-citationShaker, S. B., von Wachenfeldt, K. A., Larsson, S., Mile, I., Persdotter, S., Dahlbäck, M., Broberg, P., Stoel, B. C., Bach, K., Hestad, M., et al. (2007) · The Clinical Respiratory Journal · doi:10.1111/j.1752-699x.2007.00032.x · Cited by 35
Self-citationMulti-level classification of emphysema in HRCT lung images
Prasad, M. N., Sowmya, A., & Wilson, P. (2007) · Pattern Analysis and Applications · doi:10.1007/s10044-007-0093-7 · Cited by 34
Airway Tree Extraction with Locally Optimal Paths
Lo, P., Jon Sporring, A., Pedersen, J. J. H., & de Bruijne, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-04271-3_7 · Cited by 30
Research works printed but not linked: 16
- schwaiblmair, 1998, relations between cardiopulmonary exercise testing and quantitative high-resolution computed tomography associated in patients with alpha-1-antitrypsin deficiency, Eur J Med Res, 3, 527
- loog, 2004, static posterior probability fusion for signal detection: applications in the detection of interstitial diseases in chest radiographs, Proc ICPR (1), 644
- lo, 2009, MICCAI (1), 51
- 10.1109/ICPR.2002.1044781 · doi:10.1109/icpr.2002.1044781
- 10.1164/ajrccm.161.4.9905040 · doi:10.1164/ajrccm.161.4.9905040
- 10.1148/radiol.2283020505 · doi:10.1148/radiol.2283020505
- 10.1097/RLI.0b013e31816901c7 · DOI
- 10.1142/S1469026808002387 · doi:10.1142/s1469026808002387
- srensen, 2008, MICCAI (1), 934
- duin, 1998, SSPR/SPR, 611
- 10.1109/51.473275 · doi:10.1109/51.473275
- 10.1016/S0033-8389(05)70005-1 · doi:10.1016/s0033-8389(05)70005-1
- srensen, 2008, texture based emphysema quantification in lung ct, Proc 1st Int Workshop Pulm Image Anal, 5
- dirksen, 1998, long-range correlations of serial fev1 measurements in emphysematous patients and normal subjects, J Appl Physiol, 85, 259, 10.1152/jappl.1998.85.1.259 · doi:10.1152/jappl.1998.85.1.259
- 10.1109/IEMBS.2007.4352735 · doi:10.1109/iembs.2007.4352735
- 10.1164/ajrccm-conference.2009.179.1_MeetingAbstracts.A5573 · doi:10.1164/ajrccm-conference.2009.179.1_meetingabstracts.a5573
Cited by
Medical image analysis using convolutional neural networks: a review
Anwar, S. M., Majid, M., Qayyum, A., Awais, M., Alnowami, M., & Khan, M. K. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-1088-1 · Cited by 1,431
Lung pattern classification for interstitial lung diseases using a deep convolutional neural network
Anthimopoulos, M., Christodoulidis, S., Ebner, L., Christe, A., & Mougiakakou, S. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2535865 · Cited by 1,343
Cheng, J.-Z., Ni, D., Chou, Y.-H., Qin, J., Tiu, C.-M., Chang, Y.-C., Huang, C.-S., Shen, D., & Chen, C.-M. (2016) · Scientific Reports · doi:10.1038/srep24454 · Cited by 755
Xie, Y., Xia, Y., Zhang, J., Song, Y., Feng, D., Fulham, M., & Cai, W. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2876510 · Cited by 496
Radiomics and radiogenomics in lung cancer: A review for the clinician
Thawani, R., McLane, M., Beig, N., Ghose, S., Prasanna, P., Velcheti, V., & Madabhushi, A. (2018) · Lung Cancer · doi:10.1016/j.lungcan.2017.10.015 · Cited by 450
Metadata
- Authors
- Srensen, L., Shaker, S. B., & de Bruijne, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-02
- Volume
- 29
- Issue
- 2
- Pages
- 559-569
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2155662634
- Cited by
- 367
- References
- 35
- FWCI
- 14.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.