The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Advanced Level-Set-Based Cell Tracking in Time-Lapse Fluorescence Microscopy
Abstract
Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topological changes occurring during mitosis, and they easily extend to higher dimensional image data. This model evolution approach has also been extended to deal with many cells concurrently. Notwithstanding its high potential, the multiple-level-set method suffers from a number of shortcomings, which limit its applicability to a larger variety of cell biological imaging studies. In this paper, we propose several modifications and extensions to the coupled-active-surfaces algorithm, which considerably improve its robustness and applicability. Our algorithm was validated by comparing it to the original algorithm and two other cell segmentation algorithms. For the evaluation, four real fluorescence microscopy image datasets were used, involving different cell types and labelings that are representative of a large range of biological experiments. Improved tracking performance in terms of precision (up to 11%), recall (up to 8%), ability to correctly capture all cell division events, and computation time (up to nine times reduction) is achieved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
CellProfiler: image analysis software for identifying and quantifying cell phenotypes
Carpenter, A. E., Jones, T. R., Lamprecht, M. R., Clarke, C., Kang, I. H., Friman, O., Guertin, D. A., Chang, J. H., Lindquist, R. A., Moffat, J., et al. (2006) · Genome Biology · doi:10.1186/gb-2006-7-10-r100 · Cited by 5,157
Level Set Methods and Dynamic Implicit Surfaces
Osher, S., & Fedkiw, R. (2003) · Applied Mathematical Sciences · doi:10.1007/b98879 · Cited by 4,951
Survey over image thresholding techniques and quantitative performance evaluation
Sankur, B. (2004) · Journal of Electronic Imaging · doi:10.1117/1.1631315 · Cited by 4,583
Handbook Of Biological Confocal Microscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-45524-2 · Cited by 3,637
Byrt, T., Bishop, J., & Carlin, J. B. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90018-v · Cited by 2,179 · cited 1×
“This was done by using a similar measure to the bias index [ 68 ], which is the measure that is commonly used in epidemiology.”
MethodWarfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
The Radon Transform and Some of Its Applications
Deans, S. R. (1983) · Cited by 2,055
Handbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Light Microscopy Techniques for Live Cell Imaging
Stephens, D. J., & Allan, V. J. (2003) · Science · doi:10.1126/science.1082160 · Cited by 1,179
Level set methods and dynamic implicit surfaces
(2003) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(03)90179-9 · Cited by 986
Quantitative Comparison of Algorithms for Tracking Single Fluorescent Particles
Cheezum, M. K., Walker, W. F., & Guilford, W. H. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75884-5 · Cited by 896
CellProfiler™: Free, Versatile Software for Automated Biological Image Analysis
Lamprecht, M. R., Sabatini, D. M., & Carpenter, A. E. (2007) · BioTechniques · doi:10.2144/000112257 · Cited by 895
MCMC-based particle filtering for tracking a variable number of interacting targets
Khan, Z., Balch, T., & Dellaert, F. (2005) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2005.223 · Cited by 771
Geodesic Active Regions and Level Set Methods for Supervised Texture Segmentation
Paragios, N., & Deriche, R. (2002) · International Journal of Computer Vision · doi:10.1023/a:1014080923068 · Cited by 754
Computing geodesics and minimal surfaces via graph cuts
Boykov, & Kolmogorov (2003) · Proceedings Ninth IEEE International Conference on Computer Vision · doi:10.1109/iccv.2003.1238310 · Cited by 555
Nuclear Dynamics of PCNA in DNA Replication and Repair
Essers, J., Theil, A. F., Baldeyron, C., van Cappellen, W. A., Houtsmuller, A. B., Kanaar, R., & Vermeulen, W. (2005) · Molecular and Cellular Biology · doi:10.1128/mcb.25.21.9350-9359.2005 · Cited by 439
Self-citationYang, X., Li, H., & Zhou, X. (2006) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2006.884469 · Cited by 404
High-throughput RNAi screening by time-lapse imaging of live human cells
Neumann, B., Held, M., Liebel, U., Erfle, H., Rogers, P., Pepperkok, R., & Ellenberg, J. (2006) · Nature Methods · doi:10.1038/nmeth876 · Cited by 379
The Radon Transform and Some of Its Applications
Fiddy, M. A. (1985) · Optica Acta International Journal of Optics · doi:10.1080/713821644 · Cited by 366
Automated cell lineage tracing in Caenorhabditis elegans
Bao, Z., Murray, J. I., Boyle, T., Ooi, S. L., Sandel, M. J., & Waterston, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0511111103 · Cited by 364
Cell population tracking and lineage construction with spatiotemporal context
Li, K., Miller, E. D., Chen, M., Kanade, T., Weiss, L. E., & Campbell, P. G. (2008) · Medical Image Analysis · doi:10.1016/j.media.2008.06.001 · Cited by 346
Bioimage informatics: a new area of engineering biology
Peng, H. (2008) · Bioinformatics · doi:10.1093/bioinformatics/btn346 · Cited by 346
Automated Segmentation, Classification, and Tracking of Cancer Cell Nuclei in Time-Lapse Microscopy
Chen, X., Zhou, X., & Wong, S. T. C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.870201 · Cited by 332
Mansfield, J. R., Gossage, K. W., Hoyt, C. C., & Levenson, R. M. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2032458 · Cited by 311 · cited 1×
“Fifth, fluorescence microscopy images may contain autofluorescence [ 21 ], interfering with the signal of interest.”
BackgroundSegmenting and tracking fluorescent cells in dynamic 3-D microscopy with coupled active surfaces
Dufour, A., Shinin, V., Tajbakhsh, S., Guillen-Aghion, N., Olivo-Marin, J.-C., & Zimmer, C. (2005) · IEEE Transactions on Image Processing · doi:10.1109/tip.2005.852790 · Cited by 309
Tracking of migrating cells under phase-contrast video microscopy with combined mean-shift processes
Debeir, O., Van Ham, P., Kiss, R., & Decaestecker, C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.846851 · Cited by 298
A variational framework for active and adaptative segmentation of vector valued images
Rousson, M., & Deriche, R. (2003) · Workshop on Motion and Video Computing, 2002. Proceedings. · doi:10.1109/motion.2002.1182214 · Cited by 244
Tsien, R. Y. (2003) · PubMed · Cited by 228
Level Set Analysis for Leukocyte Detection and Tracking
Mukherjee, D. P., Ray, N., & Acton, S. T. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819858 · Cited by 209
Using Particles to Track Varying Numbers of Interacting People
Smith, K., Gatica-Perez, D., & Odobez, J. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.361 · Cited by 208
Tracking Deforming Objects Using Particle Filtering for Geometric Active Contours
Yogesh Rathi, A., Vaswani, N., Tannenbaum, A., & Yezzi, A. J. (2007) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2007.1081 · Cited by 172
Al-Kofahi, O., Radke, R. J., Goderie, S. K., Shen, Q., Temple, S., & Roysam, B. (2006) · Cell Cycle · doi:10.4161/cc.5.3.2426 · Cited by 172
Computational imaging in cell biology
Eils, R., & Athale, C. A. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200302097 · Cited by 166
Tracking single particles: a user-friendly quantitative evaluation
Carter, B. C., Shubeita, G. T., & Gross, S. P. (2005) · Physical Biology · doi:10.1088/1478-3967/2/1/008 · Cited by 152
Time-lapse Imaging Reveals Dynamic Relocalization of PP1γ throughout the Mammalian Cell Cycle
Trinkle‐Mulcahy, L., Andrews, P. D., Wickramasinghe, S. R., Sleeman, J., Prescott, A. R., Lam, Y. W., Lyon, C. E., Swedlow, J. R., & Lamond, A. I. (2003) · Molecular Biology of the Cell · doi:10.1091/mbc.e02-07-0376 · Cited by 145
Novel cell segmentation and online SVM for cell cycle phase identification in automated microscopy
Wang, M., Zhou, X., Li, F., Huckins, J. F., King, R. W., & Wong, S. T. C. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm530 · Cited by 136
Cell Segmentation Using Coupled Level Sets and Graph-Vertex Coloring
Nath, S. K., Palaniappan, K., & Bunyak, F. (2006) · Lecture notes in computer science · doi:10.1007/11866565_13 · Cited by 118
Dormann, D., & Weijer, C. J. (2006) · The EMBO Journal · doi:10.1038/sj.emboj.7601227 · Cited by 117
A streaming narrow-band algorithm: interactive computation and visualization of level sets
Lefohn, A. E., Kniss, J. M., Hansen, C. D., & Whitaker, R. (2004) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2004.2 · Cited by 107
Kevil, C. G., Orr, A. W., Langston, W., Mickett, K., Murphy-Ullrich, J. E., Patel, R. P., Kucik, D. F., & Bullard, D. C. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m312025200 · Cited by 100
Simultaneous quantification of cell motility and protein‐membrane‐association using active contours
Dormann, D., Libotte, T., Weijer, C. J., & Bretschneider, T. (2002) · Cell Motility and the Cytoskeleton · doi:10.1002/cm.10048 · Cited by 98
On the digital trail of mobile cells
Zimmer, C., Zhang, B., Dufour, A., Thebaud, A., Berlemont, S., Meas‐Yedid, V., & Olivo‐Marín, J. (2006) · IEEE Signal Processing Magazine · doi:10.1109/msp.2006.1628878 · Cited by 92
Rao-Blackwellized Monte Carlo Data Association for Multiple Target Tracking
Särkkä, S., Vehtari, A., & Lampinen, J. (2004) · Cited by 73
New dimensions in cell migration
Webb, D. J., & Horwitz, A. F. (2003) · Nature Cell Biology · doi:10.1038/ncb0803-690 · Cited by 66
Dynamics of Relative Chromosome Position during the Cell Cycle
Essers, J., van Cappellen, W. A., Theil, A. F., van Drunen, E., Jaspers, N. G. J., Hoeijmakers, J. H. J., Wyman, C., Vermeulen, W., & Kanaar, R. (2004) · Molecular Biology of the Cell · doi:10.1091/mbc.e04-10-0876 · Cited by 57
Self-citationAutomatic tracking of biological cells and compartments using particle filters and active contours
Shen, H., Nelson, G., Kennedy, S. M., Nelson, D. E., Johnson, J. R., Spiller, D. G., White, M., & Kell, D. B. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2005.07.007 · Cited by 52
High content image analysis for human H4 neuroglioma cells exposed to CuO nanoparticles
Li, F., Zhou, X., Zhu, J., Ma, J., Huang, X., & Wong, S. T. C. (2007) · BMC Biotechnology · doi:10.1186/1472-6750-7-66 · Cited by 51
McCullough, D. P., Gudla, P. R., Harris, B. S., Collins, J. A., Meaburn, K. J., Nakaya, M., Yamaguchi, T. P., Misteli, T., & Lockett, S. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.913135 · Cited by 46
Harder, N., Mora‐Bermúdez, F., Godinez, W. J., Ellenberg, J., Eils, R., & Rohr, K. (2006) · Lecture notes in computer science · doi:10.1007/11866565_103 · Cited by 44
Meijering, E. H. W., Smal, I., Dzyubachyk, O., & Olivo‐Marín, J. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-372578-3.00015-5 · Cited by 40
Self-citationFast sub-voxel re-initialization of the distance map for level set methods
Krissian, K., & Westin, C. (2005) · Pattern Recognition Letters · doi:10.1016/j.patrec.2004.12.005 · Cited by 27
Cited by
Methods for Cell and Particle Tracking
Meijering, E., Dzyubachyk, O., & Smal, I. (2012) · Methods in Enzymology · doi:10.1016/b978-0-12-391857-4.00009-4 · Cited by 1,400
Self-citationAn objective comparison of cell-tracking algorithms
Ulman, V., Maška, M., Magnusson, K. E. G., Ronneberger, O., Haubold, C., Harder, N., Matula, P., Matula, P., Svoboda, D., Radojevic, M., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4473 · Cited by 565
Self-citationXing, F., & Yang, L. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2515127 · Cited by 519
Cell Segmentation: 50 Years Down the Road [Life Sciences]
Meijering, E. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2204190 · Cited by 472
Self-citationA benchmark for comparison of cell tracking algorithms
Maška, M., Ulman, V., Svoboda, D., Matula, P., Matula, P., Ederra, C., Urbiola, A., España, T., Venkatesan, S., Balak, D. M. W., et al. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btu080 · Cited by 415
Self-citation
Metadata
- Authors
- Dzyubachyk, O., van Cappellen, W. A., Essers, J., Niessen, W. J., & Meijering, E.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2010-03
- Volume
- 29
- Issue
- 3
- Pages
- 852-867
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2100138660
- Cited by
- 255
- References
- 54
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.