The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Fast $\ell_1$-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible Runtime
Open accessAbstract
We present l₁-SPIRiT, a simple algorithm for auto calibrating parallel imaging (acPI) and compressed sensing (CS) that permits an efficient implementation with clinically-feasible runtimes. We propose a CS objective function that minimizes cross-channel joint sparsity in the wavelet domain. Our reconstruction minimizes this objective via iterative soft-thresholding, and integrates naturally with iterative self-consistent parallel imaging (SPIRiT). Like many iterative magnetic resonance imaging reconstructions, l₁-SPIRiT's image quality comes at a high computational cost. Excessively long runtimes are a barrier to the clinical use of any reconstruction approach, and thus we discuss our approach to efficiently parallelizing l₁-SPIRiT and to achieving clinically-feasible runtimes. We present parallelizations of l₁-SPIRiT for both multi-GPU systems and multi-core CPUs, and discuss the software optimization and parallelization decisions made in our implementation. The performance of these alternatives depends on the processor architecture, the size of the image matrix, and the number of parallel imaging channels. Fundamentally, achieving fast runtime requires the correct trade-off between cache usage and parallelization overheads. We demonstrate image quality via a case from our clinical experimentation, using a custom 3DFT spoiled gradient echo (SPGR) sequence with up to 8× acceleration via Poisson-disc undersampling in the two phase-encoded directions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,703
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Ideal spatial adaptation by wavelet shrinkage
Donoho, D. L., & Johnstone, I. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.425 · Cited by 8,760
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
An iterative thresholding algorithm for linear inverse problems with a sparsity constraint.
Daubechies, I., Defrise, M., & De Mol, C. (2004) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20042 · Cited by 4,958
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
(2006) · Cited by 1,979
Gustafson, J. L. (1988) · Communications of the ACM · doi:10.1145/42411.42415 · Cited by 1,450
An EM algorithm for wavelet-based image restoration
Figueiredo, M. A. T., & Nowak, R. D. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.814255 · Cited by 1,219
Advances in sensitivity encoding with arbitrary k‐space trajectories
Pruessmann, K. P., Weiger, M., Börnert, P., & Boesiger, P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1241 · Cited by 1,211
Block, K. T., Uecker, M., & Frahm, J. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21236 · Cited by 824
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
Self-citation(2004) · Cited by 742
Otazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
Image compression via joint statistical characterization in the wavelet domain
Buccigrossi, R. W., & Simoncelli, E. P. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.806616 · Cited by 523
Homodyne detection in magnetic resonance imaging
Noll, D. C., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.79473 · Cited by 514
Accelerating SENSE using compressed sensing
Liang, D., Liu, B., Wang, J., & Ying, L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22161 · Cited by 474
Rapid gridding reconstruction with a minimal oversampling ratio
Beatty, P. J., Nishimura, D. G., & Pauly, J. M. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.848376 · Cited by 333
Improved Pediatric MR Imaging with Compressed Sensing
Vasanawala, S. S., Alley, M. T., Hargreaves, B. A., Barth, R. A., Pauly, J. M., & Lustig, M. S. (2010) · Radiology · doi:10.1148/radiol.10091218 · Cited by 268
Self-citationArray compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 257
Uecker, M., Hohage, T., Block, K. T., & Frahm, J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21691 · Cited by 253
Accelerating advanced MRI reconstructions on GPUs
Stone, S. S., Haldar, J. P., Tsao, S. C., Hwu, W.-M. W., Sutton, B. P., & Liang, Z.-P. (2008) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2008.05.013 · Cited by 249
Vasanawala, S., Murphy, M., Alley, M., Lai, P., Keutzer, K., Pauly, J., & Lustig, M. (2011) · 2011 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2011.5872579 · Cited by 172
Self-citationAccelerating the Nonequispaced Fast Fourier Transform on Commodity Graphics Hardware
Sørensen, T. S., Schaeffter, T., Noe, K. Ø., & Hansen, M. S. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.909834 · Cited by 104
Parallel imaging with nonlinear reconstruction using variational penalties
Knöll, F., Clason, C., Bredies, K., Uecker, M., & Stollberger, R. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22964 · Cited by 102
Sørensen, T. S., Atkinson, D., Schaeffter, T., et al. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2027118 · Cited by 63
Huang, F., Chen, Y., Yin, W., Lin, W., Ye, X., Guo, W., & Reykowski, A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22504 · Cited by 51
Sparse‐CAPR: Highly accelerated 4D CE‐MRA with parallel imaging and nonconvex compressive sensing
Trzasko, J. D., Haider, C. R., Borisch, E. A., Campeau, N. G., Glockner, J. F., Riederer, S. J., & Manduca, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22892 · Cited by 45
Online real‐time reconstruction of adaptive TSENSE with commodity CPU/GPU hardware
Roujol, S., de Senneville, B. D., Vahala, E. T., et al. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22112 · Cited by 36
Wu, X., Gai, J., Lam, F., et al. (2011) · IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI) · doi:10.1109/isbi.2011.5872356 · Cited by 32
High-Performance 3D Compressive Sensing MRI Reconstruction Using Many-Core Architectures
Kim, D., Trzasko, J. D., Smelyanskiy, M., Haider, C. R., Dubey, P. K., & Manduca, A. (2011) · International Journal of Biomedical Imaging · doi:10.1155/2011/473128 · Cited by 31
Cited by
ESPIRiT—an eigenvalue approach to autocalibrating parallel MRI: Where SENSE meets GRAPPA
Uecker, M., Lai, P., Murphy, M. J., Virtue, P., Elad, M., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24751 · Cited by 1,392
Self-citationYang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
Eo, T., Jun, Y., Kim, T., Jang, J., Lee, H., & Hwang, D. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27201 · Cited by 455
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Calibrationless parallel imaging reconstruction based on structured low-rank matrix completion
Shin, P. J., Larson, P. E. Z., Ohliger, M. A., Elad, M., Pauly, J. M., Vigneron, D. B., & Lustig, M. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24997 · Cited by 391
Self-citation
Metadata
- Authors
- Murphy, M., Alley, M., Demmel, J., Keutzer, K., Vasanawala, S., & Lustig, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2012-06
- Volume
- 31
- Issue
- 6
- Pages
- 1250-1262
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2115723093
- Cited by
- 313
- References
- 34
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.