The DOI matches its Crossref record.
Analysis of a 3-D System Function Measured for Magnetic Particle Imaging
Abstract
Magnetic particle imaging (MPI) is a new tomographic imaging approach that can quantitatively map magnetic nanoparticle distributions in vivo. It is capable of volumetric real-time imaging at particle concentrations low enough to enable clinical applications. For image reconstruction in 3-D MPI, a system function (SF) is used, which describes the relation between the acquired MPI signal and the spatial origin of the signal. The SF depends on the instrumental configuration, the applied field sequence, and the magnetic particle characteristics. Its properties reflect the quality of the spatial encoding process. This work presents a detailed analysis of a measured SF to give experimental evidence that 3-D MPI encodes information using a set of 3-D spatial patterns or basis functions that is stored in the SF. This resembles filling 3-D k-space in magnetic resonance imaging, but is faster since all information is gathered simultaneously over a broad acquisition bandwidth. A frequency domain analysis shows that the finest structures that can be encoded with the presented SF are as small as 0.6 mm. SF simulations are performed to demonstrate that larger particle cores extend the set of basis functions towards higher resolution and that the experimentally observed spatial patterns require the existence of particles with core sizes of about 30 nm in the calibration sample. A simple formula is presented that qualitatively describes the basis functions to be expected at a certain frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic Particle Imaging (MPI) for NMR and MRI researchers
Saritas, E. U., Goodwill, P. W., Croft, L. R., Konkle, J. J., Lu, K., Zheng, B., & Conolly, S. M. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.029 · Cited by 307
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“The first is a system matrix-based reconstruction that depends on a supplemental calibration scan that is performed by moving a delta-sample by robotic means, 1,21,22 and the second is a direct reconstruction known as x-space MPI, which is based on some idealized assumptions.”
BackgroundMagnetic particle imaging with tailored iron oxide nanoparticle tracers
Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Arami, H., Saritas, E. U., Croft, L. R., Konkle, J., Goodwill, P. W., Halkola, A., Rahmer, J., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2375065 · Cited by 222
Self-citationPablico-Lansigan, M. H., Situ, S. F., & Samia, A. C. S. (2013) · Nanoscale · doi:10.1039/c3nr00544e · Cited by 172
Metadata
- Authors
- Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2012-06
- Volume
- 31
- Issue
- 6
- Pages
- 1289-1299
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2084885041
- Cited by
- 171
- References
- 0
- FWCI
- 6.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analysis of a 3-D System Function Measured for Magnetic Particle Imaging. https://app.cochat.ai/papers/10.1109/tmi.2012.2188639
- The paper
- Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2012). Analysis of a 3-D System Function Measured for Magnetic Particle Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2012.2188639
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.