Increasing the Automation of a 2D-3D Registration System
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Routine clinical use of 2D-3D registration algorithms for Image Guided Surgery remains limited. A key aspect for routine clinical use of this technology is its degree of automation, i.e., the amount of necessary knowledgeable interaction between the clinicians and the registration system. Current image-based registration approaches usually require knowledgeable manual interaction during two stages: for initial pose estimation and for verification of produced results. We propose four novel techniques, particularly suited to vertebra-based registration systems, which can significantly automate both of the above stages. Two of these techniques are based upon the intraoperative "insertion" of a virtual fiducial marker into the preoperative data. The remaining two techniques use the final registration similarity value between multiple CT vertebrae and a single fluoroscopy vertebra. The proposed methods were evaluated with data from 31 operations (31 CT scans, 419 fluoroscopy images). Results show these methods can remove the need for manual vertebra identification during initial pose estimation, and were also very effective for result verification, producing a combined true positive rate of 100% and false positive rate equal to zero. This large decrease in required knowledgeable interaction is an important contribution aiming to enable more widespread use of 2D-3D registration technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
GPU Accelerated Generation of Digitally Reconstructed Radiographs for 2-D/3-D Image Registration
Dorgham, O. M., Laycock, S. D., & Fisher, M. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2207898 · Cited by 56
Gendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Penney, G., Varnavas, A., Dastur, N., & Carrell, T. (2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-21504-9_2 · Cited by 22
Self-citation
Cited by
Otake, Y., Wang, A. S., Webster Stayman, J., Uneri, A., Kleinszig, G., Vogt, S., Khanna, A. J., Gokaslan, Z. L., & Siewerdsen, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/23/8535 · Cited by 89
“…et al (2012c) reported ~500 eval s −1 , Fisher et al (2013) reported ~400 eval s −1 (DRR rendering speed), Dorgham et al (2012) reported ~167 eval s −1 , Varnavas et al (2013) reported ~21.5 eval s −1 , Steininger et al (2012) reported ~13.3 eval s −1 , and Spoerk et al (2012) ~9–22 eval s −1 .”
BackgroundInfluentialFully automated 2D–3D registration and verification
Varnavas, A., Carrell, T., & Penney, G. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.08.005 · Cited by 50
Self-citation3D–2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation
Otake, Y., Wang, A. S., Uneri, A., Kleinszig, G., Vogt, S., Aygun, N., Lo, S.-F. L., Wolinsky, J.-P., Gokaslan, Z. L., & Siewerdsen, J. H. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/5/2075 · Cited by 41
“For example, in acquisition of a mobile radiograph, the operator places the source and detector manually in a desired orientation (e.g. view) posterior–anterior (PA) or lateral (LAT) with the source roughly centered on the detector (Varnavas et al 2013).”
BackgroundFully automated initialisation of 2D–3D image registration
Varnavas, A., Carrell, T., & Penney, G. (2013) · 2013 IEEE 10th International Symposium on Biomedical Imaging · doi:10.1109/isbi.2013.6556538 · Cited by 9
“A number of techniques to significantly reduce the amount of required knowledgeable interaction are proposed in [1].”
BackgroundSelf-citation
Metadata
- Authors
- Varnavas, A., Carrell, T., & Penney, G.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-02
- Volume
- 32
- Issue
- 2
- Pages
- 387-399
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2074502867
- Cited by
- 34
- References
- 4
- FWCI
- 6.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increasing the Automation of a 2D-3D Registration System. https://app.cochat.ai/papers/10.1109/tmi.2012.2227337
- The paper
- Varnavas, A., Carrell, T., & Penney, G. (2013). Increasing the Automation of a 2D-3D Registration System. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2012.2227337
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.