Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Magnetostimulation Limits in Magnetic Particle Imaging

Saritas, Emine U., Goodwill, Patrick W., Zhang, George Z., Conolly, Steven M.·2013·IEEE Transactions on Medical Imaging

Abstract

For magnetic particle imaging (MPI), specific absorption rate (SAR) and more critically magnetostimulation (i.e., dB/dt) safety limits will determine the optimal scan parameters, such as the drive field strength and frequency. These parameters will impact the scanning speed, field-of-view (FOV) and signal-to-noise ratio in MPI. Understanding the potential safety hazards of the drive field is critical for scaling MPI for human use. In this work, we demonstrate that magnetostimulation is the primary magnetic safety consideration in MPI, and we describe the first human-subject magnetostimulation threshold experiments for MPI using homogeneous coils. Our experiments, performed on the arm and leg, indicate that magnetostimulation thresholds monotonically decrease with increasing frequency. Additionally, we show for the first time that a strong inverse correlation exists between the threshold and the body part size. The chronaxie time, on the other hand, did not vary with body part size. We conclude with an estimation of the magnetostimulation thresholds for a full-body MPI scanner: a mean asymptotic threshold of 14.3 mT-pp (peak-to-peak) with a mean chronaxie time of 289 μs, which correspond to a magnetostimulation threshold of about 15 mT-pp for frequencies between 25 and 50 kHz. These findings will have a great impact on the optimization of MPI parameters, especially in determining the number of partial FOVs required to cover a region of interest.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2013.2260764

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 173

Metadata

Authors
Saritas, E. U., Goodwill, P. W., Zhang, G. Z., & Conolly, S. M.
Venue
IEEE Transactions on Medical Imaging
Published
2013-09
Volume
32
Issue
9
Pages
1600-1610
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2054699716
Cited by
173
References
1
FWCI
4.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetostimulation Limits in Magnetic Particle Imaging. https://app.cochat.ai/papers/10.1109/tmi.2013.2260764
The paper
Saritas, E. U., Goodwill, P. W., Zhang, G. Z., & Conolly, S. M. (2013). Magnetostimulation Limits in Magnetic Particle Imaging. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2013.2260764

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.