The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Magnetostimulation Limits in Magnetic Particle Imaging
Abstract
For magnetic particle imaging (MPI), specific absorption rate (SAR) and more critically magnetostimulation (i.e., dB/dt) safety limits will determine the optimal scan parameters, such as the drive field strength and frequency. These parameters will impact the scanning speed, field-of-view (FOV) and signal-to-noise ratio in MPI. Understanding the potential safety hazards of the drive field is critical for scaling MPI for human use. In this work, we demonstrate that magnetostimulation is the primary magnetic safety consideration in MPI, and we describe the first human-subject magnetostimulation threshold experiments for MPI using homogeneous coils. Our experiments, performed on the arm and leg, indicate that magnetostimulation thresholds monotonically decrease with increasing frequency. Additionally, we show for the first time that a strong inverse correlation exists between the threshold and the body part size. The chronaxie time, on the other hand, did not vary with body part size. We conclude with an estimation of the magnetostimulation thresholds for a full-body MPI scanner: a mean asymptotic threshold of 14.3 mT-pp (peak-to-peak) with a mean chronaxie time of 289 μs, which correspond to a magnetostimulation threshold of about 15 mT-pp for frequencies between 25 and 50 kHz. These findings will have a great impact on the optimization of MPI parameters, especially in determining the number of partial FOVs required to cover a region of interest.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The SAR threshold curve was calculated for a 4 W/kg limit (adopted from the typical SAR restriction for controlled mode whole body MRI scans [17]), using the frequency-dependent muscle resistivity values given in [25].”
MethodStrength-duration properties of human peripheral nerve
Mogyoros, I., Kiernan, M. C., & Burke, D. (1996) · Brain · doi:10.1093/brain/119.2.439 · Cited by 358 · cited 2×
“One electric stimulation study showed that, when tested using the same stimulation configuration, chronaxie times for motor axons did not vary significantly at wrist and elbow levels [36].”
BackgroundMethod
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Human-sized magnetic particle imaging for brain applications
Graeser, M., Thieben, F., Szwargulski, P., Werner, F., Gdaniec, N., Boberg, M., Griese, F., Möddel, M., Ludewig, P., van de Ven, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09704-x · Cited by 334
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“…may lead to the aforementioned PNS. 64,66 A conclusion that can be drawn from current studies on PNS is that the amplitude of the drive field in a clinical MPI system will have to be clearly below 10 mT. 63 This is much lower than on preclinical systems that use amplitudes up to twice as high.”
BackgroundFirst in vivo traveling wave magnetic particle imaging of a beating mouse heart
Vogel, P., Rückert, M. A., Klauer, P., Kullmann, W. H., Jakob, P. M., & Behr, V. C. (2016) · Physics in Medicine & Biology · doi:10.1088/0031-9155/61/18/6620 · Cited by 60
Metadata
- Authors
- Saritas, E. U., Goodwill, P. W., Zhang, G. Z., & Conolly, S. M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2013-09
- Volume
- 32
- Issue
- 9
- Pages
- 1600-1610
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2054699716
- Cited by
- 173
- References
- 2
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.